Modeling AeroForm tissue expander for postmastectomy radiation therapy.

来自 PUBMED

作者:

Dziemianowicz EGardner SJChin Snyder KWen NWalker EMFraser CReding AChetty IJ

展开

摘要:

The AeroForm chest wall tissue expander (TE) is a silicon shell containing a metallic CO2 reservoir, placed surgically after mastectomy. The patient uses a remote control to release compressed CO2 from the reservoir to inflate the expander. AeroForm poses challenges in a radiation therapy setting: The high density of the metallic reservoir causes imaging artifacts on the planning CT, which encumber structure definition and cause misrepresentation of density information, in turn affecting dose calculation. Additionally, convolution-based dose calculation algorithms may not be well-suited to calculate dose in and around high-density materials. In this study, a model of the AeroForm TE was created in Eclipse treatment planning system (TPS). The TPS model was validated by comparing measured to calculated transmission through the AeroForm. Transmission was measured with various geometries using radiochromic film. Dose was calculated with both Varian's Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) algorithms. AAA and AXB were compared using dose profile and gamma analyses. While both algorithms modeled direct transmission well, AXB better modeled lateral scatter from the AeroForm TE. Clinical significance was evaluated using clinical data from four patients with AeroForm TEs. The AeroForm TPS model was applied, and RT plans were optimized using AAA, then re-calculated with AXB. Structures of clinical significance were defined and dose volume histogram analysis was performed. Compared to AXB, AAA overestimates dose in the AeroForm device. Changes in clinically significant regions were patient- and plan-specific. This study proposes a clinical procedure for modeling the AeroForm in a commercial TPS, and discusses the limitations of dose calculation in and around the device. An understanding of dose calculation accuracy in the vicinity of the AeroForm is critical for assessing individual plan quality, appropriateness of different planning techniques and dose calculation algorithms, and even the decision to use the AeroForm in a postmastectomy radiation therapy setting.

收起

展开

DOI:

10.1002/acm2.12682

被引量:

1

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(147)

参考文献(20)

引证文献(1)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读