A dosimetry study of post-mastectomy radiation therapy with AeroForm tissue expander.
摘要:
To evaluate the dosimetric effects of the AeroFormTM (AirXanpders®, Palo Alto, CA) tissue expander in-situ for breast cancer patients receiving post-mastectomy radiation therapy. A film phantom (P1) was constructed by placing the metallic canister of the AeroForm on a solid water phantom with EBT3 films at five depths ranging from 2.6 mm to 66.2 mm. A breast phantom (P2), a three-dimensional printed tissue-equivalent breast with fully expanded AeroForm in-situ, was placed on a thorax phantom. A total of 21 optical luminescent dosimeters (OLSDs) were placed on the anterior skin-gas interface and the posterior chest wall-metal interface of the AeroForm. Both phantoms were imaged with a 16-bit computed tomography scanner with orthopedic metal artifact reduction. P1 was irradiated with an open field utilizing 6 MV and 15 MV photon beams at 0°, 90°, and 270°. P2 was irradiated using a volumetric modulated arc therapy plan with a 6 MV photon beam and a tangential plan with a 15 MV photon beam. All doses were calculated using Eclipse (Varian, Palo Alto, CA) with AAA and AcurosXB (AXB) algorithms. The average dose differences between film measurements and AXB in the region adjacent to the canister in P1 were within 3.1% for 15 MV and 0.9% for 6 MV. Local dose differences over 10% were also observed. In the chest wall region of P2, the median dose of OLSDs in percentage of prescription dose were 108.4% (range 95.4%-113.0%) for the 15MV tangential plan and 110.4% (range 99.1%-113.8%) for the 6MV volumetric modulated arc therapy plan. In the skin-gas interface, the median dose of the OLSDs were 102.3% (range 92.7%-107.7%) for the 15 MV plan and 108.2% (range 97.8-113.5%) for the 6 MV plan. Measured doses were, in general, higher than calculated doses with AXB calculations. The AAA dose algorithms produced results with slightly larger discrepancies between measurements compared with AXB. The AeroForm creates significant dose uncertainties in the chest wall-metal interface. The AcurosXB dose calculation algorithm is recommended for more accurate calculations. If possible, post-mastectomy radiation therapy should be delivered after the permanent implant is in place.
收起
展开
DOI:
10.1002/acm2.12962
被引量:
年份:
1970


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(171)
参考文献(15)
引证文献(2)
来源期刊
影响因子:2.241
JCR分区: 暂无
中科院分区:暂无