A dosimetry study of post-mastectomy radiation therapy with AeroForm tissue expander.

来自 PUBMED

作者:

Lim SBKuo LCLi GKuo HCMcCormick BCahlon OPowell SHong LX

展开

摘要:

To evaluate the dosimetric effects of the AeroFormTM (AirXanpders®, Palo Alto, CA) tissue expander in-situ for breast cancer patients receiving post-mastectomy radiation therapy. A film phantom (P1) was constructed by placing the metallic canister of the AeroForm on a solid water phantom with EBT3 films at five depths ranging from 2.6 mm to 66.2 mm. A breast phantom (P2), a three-dimensional printed tissue-equivalent breast with fully expanded AeroForm in-situ, was placed on a thorax phantom. A total of 21 optical luminescent dosimeters (OLSDs) were placed on the anterior skin-gas interface and the posterior chest wall-metal interface of the AeroForm. Both phantoms were imaged with a 16-bit computed tomography scanner with orthopedic metal artifact reduction. P1 was irradiated with an open field utilizing 6 MV and 15 MV photon beams at 0°, 90°, and 270°. P2 was irradiated using a volumetric modulated arc therapy plan with a 6 MV photon beam and a tangential plan with a 15 MV photon beam. All doses were calculated using Eclipse (Varian, Palo Alto, CA) with AAA and AcurosXB (AXB) algorithms. The average dose differences between film measurements and AXB in the region adjacent to the canister in P1 were within 3.1% for 15 MV and 0.9% for 6 MV. Local dose differences over 10% were also observed. In the chest wall region of P2, the median dose of OLSDs in percentage of prescription dose were 108.4% (range 95.4%-113.0%) for the 15MV tangential plan and 110.4% (range 99.1%-113.8%) for the 6MV volumetric modulated arc therapy plan. In the skin-gas interface, the median dose of the OLSDs were 102.3% (range 92.7%-107.7%) for the 15 MV plan and 108.2% (range 97.8-113.5%) for the 6 MV plan. Measured doses were, in general, higher than calculated doses with AXB calculations. The AAA dose algorithms produced results with slightly larger discrepancies between measurements compared with AXB. The AeroForm creates significant dose uncertainties in the chest wall-metal interface. The AcurosXB dose calculation algorithm is recommended for more accurate calculations. If possible, post-mastectomy radiation therapy should be delivered after the permanent implant is in place.

收起

展开

DOI:

10.1002/acm2.12962

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(171)

参考文献(15)

引证文献(2)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读