Outcomes of fenestrated and branched endovascular aneurysm repair with an inverted contralateral limb.

来自 PUBMED

作者:

Huistra EWMTielliu IFJde Vries JPMZeebregts CJ

展开

摘要:

To report technical success and evaluate clinical outcomes of fenestrated and branched endovascular aortic repair (F/B-EVAR) incorporating a contralateral inverted limb. Patients who underwent F/B-EVAR with a custom-made bifurcated device containing an inverted limb between January 2010 and September 2023 were retrospectively analyzed. Time-to-event data were analyzed using the Kaplan-Meier method. A total of 32 patients (26 men; mean age 77±6.2 years) were included in the analysis. Technical success was achieved in 28 patients (87.5%). Two technical failures resulted from misplaced contralateral limbs in patients with previous endovascular aortic repair (EVAR), necessitating one open conversion due to a type 3b endoleak, and one femoro-femoral crossover bypass after occlusion of a misplaced contralateral limb. Additionally, two technical failures were attributed to a type 3c endoleak and a type 1c endoleak, originating from a fenestrated device at the level of the left and right renal artery, respectively. One patient (3.1%) died <30 days post-operatively due to a subdural hemorrhage. Estimated patient survival after 1 and 2 years was 92.7%±5.1%, and 74.3%±10.1%, respectively. No aneurysm-related deaths were observed. During the median follow-up of 13 months, one (3.1%) inverted limb occluded, in addition to the occlusion resulting from a misplaced contralateral limb, and was treated with a femoro-femoral crossover bypass. One target vessel (right renal artery) occluded (0.9%), resulting in a permanent, significantly reduced renal function. Freedom from overall reintervention after 1 and 2 years was 73.5%±8.0% and 68.3%±9.0%, respectively. An additional four patients (12.5%) presented with a type 3c endoleak during follow-up scans, three of which originated from fenestrations at the level of the renal stents. There were no junctional problems between the inverted limb device and the main endograft, and no significant correlation was found between the one-sealing-stent inverted limb device design and the onset of type 3 endoleak (log-rank P=.064). F/B-EVAR incorporating an inverted limb can be a viable endovascular option to manage complex aneurysms with a short renal artery to bifurcation distance. However, using the inverted limb presents a notable technical challenge and could be associated with a higher need for reintervention. Carefully confirming correct cannulation of the inverted limb is warranted.

收起

展开

DOI:

10.1016/j.jvs.2024.07.110

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读