Outcomes using inverted iliac limb bifurcate components in fenestrated/branched endografting.

来自 PUBMED

作者:

Khoury MKBeck AWFarber MAGasper WLee WAOderich GParodi FESchanzer ASchneider DSweet MTimaran CHEagleton MJ

展开

摘要:

The use of standard bifurcate pieces in fenestrated/branched endovascular aortic repair (F/BEVAR) requires adequate length from the lowest branch or fenestration to the aortic bifurcation. In patients with prior aortic surgery, the aortic bifurcation is often artificially established in a more proximal position, compromising the infrarenal length, which hinders the placement of a standard bifurcate component below the fenestrated/branched component. Short bifurcate bodies using an inverted contralateral limb have been purpose-built to address this challenge. However, reported outcomes for this device remain limited, with specific concerns about the durability of the inverted iliac limb sealing region. We sought to evaluate outcomes of F/BEVAR using an investigational inverted iliac limb bifurcate, manufactured by Cook Medical. This study was a retrospective review of prospectively maintained data from the US-Aortic Research Consortium from 2005 to 2022. Patients were included if they underwent F/BEVAR for thoracoabdominal or complex abdominal aortic aneurysms. Patients were excluded if they did not have a bifurcate device placed. Patients were then compared based on the use of an inverted iliac limb or standard bifurcate component. The primary outcome for this study was technical success. Secondary outcomes included 30-day mortality, freedom from ischemic leg complications, freedom from type I endoleaks (TIELs), freedom from type II endoleaks (TIIELs), freedom from type III endoleaks (TIIIELs), and graft component separations. A total of 1944 patients met study criteria with 442 (22.8%) inverted iliac limb bifurcates and 1502 (77.2%) standard bifurcates. Patients who received inverted iliac limbs were more likely to have had prior aortic surgery (63.8% vs 28.5%; P < .001). Patients receiving inverted iliac limbs had longer procedure times (265 minutes; interquartile range [IQR], 201-342 minutes vs 241 minutes; IQR, 186-313 minutes; P < .001), more contrast use (89 mL [IQR, 55-135 mL] vs 109 mL [IQR, 75-156 mL]; P < .001), and higher estimated blood loss (250 mL [IQR, 150-500 mL] vs 250 mL [IQR, 110-400 mL]; P = .042). There were no differences in rates of technical success (97.3% vs 96.1%; P = .310), rates of endoleaks upon completion of the case (18.0% vs 21.4%; P = .123), or 30-day mortality rates (1.8% vs 2.5%; P = .466) between patients receiving inverted iliac limb and standard bifurcated components. There were no differences in cumulative survival, freedom from limb ischemia, freedom from aneurysm rupture, and freedom from TIIIELs over the course of 5 years between patients receiving inverted bifurcates and standard bifurcated components. Patients with inverted iliac limb bifurcate components had decreased freedom from reinterventions, TIELs, and TIIELs. After adjustment for potential confounders, the use of an inverted iliac limb was not associated with reinterventions (hazard ratio,1.044; 95% confidence interval, 0.849-1.285; P = .682). There was a total of 2 component separations (0.1%) of the bifurcate component from the fenestrated/branched component over the study period, both of which occurred in the standard bifurcate components. The use of investigational inverted iliac limb bifurcate components is a safe option with favorable mid-term outcomes in patients who are not anatomical candidates for standard bifurcate components. Patients undergoing investigational inverted iliac limb bifurcate component implantation had decreased freedom from reinterventions, which likely corresponds with the complexity of repair associated with them.

收起

展开

DOI:

10.1016/j.jvs.2024.07.095

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读