Early Versus Delayed Thoracic Endovascular Aortic Repair for Blunt Thoracic Aortic Injury: A Propensity Score-Matched Analysis.
We examined early (≤24 h) versus delayed (>24 h) thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injury (BTAI), taking the aortic injury severity into consideration.
Current trauma surgery guidelines recommend delayed TEVAR following BTAI. However, this recommendation was based on small studies, and specifics regarding recommendation strategies based on aortic injury grades are lacking.
Patients undergoing TEVAR for BTAI in the American College of Surgeons Trauma Quality Improvement Program between 2016 and 2019 were included and then stratified into 2 groups (early: ≤24 h vs. delayed: >24 h). In-hospital outcomes were compared after creating 1:1 propensity score-matched cohorts, matching for demographics, comorbidities, concomitant injuries, additional procedures, and aortic injury severity based on the acute aortic syndrome (AAS) classification.
Overall, 1339 patients were included, of whom 1054(79%) underwent early TEVAR. Compared with the delayed group, the early group had significantly less severe head injuries (early vs delayed; 25% vs 32%; P =0.014), fewer early interventions for AAS grade 1 occurred, and AAS grade 3 aortic injuries often were intervened upon within 24 hours (grade 1: 28% vs 47%; grade 3: 49% vs 23%; P <0.001). After matching, the final sample included 548 matched patients. Compared with the delayed group, the early group had a significantly higher in-hospital mortality (8.8% vs 4.4%, relative risk: 2.2, 95% CI: 1.1-4.4; P =0.028), alongside a shorter length of hospital stay (5.0 vs 10 days; P =0.028), a shorter intensive care unit length of stay (4.0 vs 11 days; P <0.001) and fewer days on the ventilator (4.0 vs 6.5 days; P =0.036). Furthermore, regardless of the higher risk of acute kidney injury in the delayed group (3.3% vs 7.7%, relative risk: 0.43, 95% CI: 0.20-0.92; P =0.029), no other differences in in-hospital complications were observed between the early and delayed group.
In this propensity score-matched analysis, delayed TEVAR was associated with lower mortality risk, even after adjusting for aortic injury grade.
Romijn AC
,Rastogi V
,Proaño-Zamudio JA
,Argandykov D
,Marcaccio CL
,Giannakopoulos GF
,Kaafarani HMA
,Jongkind V
,Bloemers FW
,Verhagen HJM
,Schermerhorn ML
,Saillant NN
... -
《-》
Outcomes using inverted iliac limb bifurcate components in fenestrated/branched endografting.
The use of standard bifurcate pieces in fenestrated/branched endovascular aortic repair (F/BEVAR) requires adequate length from the lowest branch or fenestration to the aortic bifurcation. In patients with prior aortic surgery, the aortic bifurcation is often artificially established in a more proximal position, compromising the infrarenal length, which hinders the placement of a standard bifurcate component below the fenestrated/branched component. Short bifurcate bodies using an inverted contralateral limb have been purpose-built to address this challenge. However, reported outcomes for this device remain limited, with specific concerns about the durability of the inverted iliac limb sealing region. We sought to evaluate outcomes of F/BEVAR using an investigational inverted iliac limb bifurcate, manufactured by Cook Medical.
This study was a retrospective review of prospectively maintained data from the US-Aortic Research Consortium from 2005 to 2022. Patients were included if they underwent F/BEVAR for thoracoabdominal or complex abdominal aortic aneurysms. Patients were excluded if they did not have a bifurcate device placed. Patients were then compared based on the use of an inverted iliac limb or standard bifurcate component. The primary outcome for this study was technical success. Secondary outcomes included 30-day mortality, freedom from ischemic leg complications, freedom from type I endoleaks (TIELs), freedom from type II endoleaks (TIIELs), freedom from type III endoleaks (TIIIELs), and graft component separations.
A total of 1944 patients met study criteria with 442 (22.8%) inverted iliac limb bifurcates and 1502 (77.2%) standard bifurcates. Patients who received inverted iliac limbs were more likely to have had prior aortic surgery (63.8% vs 28.5%; P < .001). Patients receiving inverted iliac limbs had longer procedure times (265 minutes; interquartile range [IQR], 201-342 minutes vs 241 minutes; IQR, 186-313 minutes; P < .001), more contrast use (89 mL [IQR, 55-135 mL] vs 109 mL [IQR, 75-156 mL]; P < .001), and higher estimated blood loss (250 mL [IQR, 150-500 mL] vs 250 mL [IQR, 110-400 mL]; P = .042). There were no differences in rates of technical success (97.3% vs 96.1%; P = .310), rates of endoleaks upon completion of the case (18.0% vs 21.4%; P = .123), or 30-day mortality rates (1.8% vs 2.5%; P = .466) between patients receiving inverted iliac limb and standard bifurcated components. There were no differences in cumulative survival, freedom from limb ischemia, freedom from aneurysm rupture, and freedom from TIIIELs over the course of 5 years between patients receiving inverted bifurcates and standard bifurcated components. Patients with inverted iliac limb bifurcate components had decreased freedom from reinterventions, TIELs, and TIIELs. After adjustment for potential confounders, the use of an inverted iliac limb was not associated with reinterventions (hazard ratio,1.044; 95% confidence interval, 0.849-1.285; P = .682). There was a total of 2 component separations (0.1%) of the bifurcate component from the fenestrated/branched component over the study period, both of which occurred in the standard bifurcate components.
The use of investigational inverted iliac limb bifurcate components is a safe option with favorable mid-term outcomes in patients who are not anatomical candidates for standard bifurcate components. Patients undergoing investigational inverted iliac limb bifurcate component implantation had decreased freedom from reinterventions, which likely corresponds with the complexity of repair associated with them.
Khoury MK
,Beck AW
,Farber MA
,Gasper W
,Lee WA
,Oderich G
,Parodi FE
,Schanzer A
,Schneider D
,Sweet M
,Timaran CH
,Eagleton MJ
... -
《-》