-
Interim safety and immunogenicity of COVID-19 omicron BA.1 variant-containing vaccine in children in the USA: an open-label non-randomised phase 3 trial.
Variant-containing mRNA vaccines for COVID-19 to broaden protection against SARS-CoV-2 variants are recommended based on findings in adults. We report interim safety and immunogenicity of an omicron BA.1 variant-containing (mRNA-1273.214) primary vaccination series and booster dose in paediatric populations.
This open-label, two-part, non-randomised phase 3 trial enrolled participants aged 6 months to 5 years at 24 US study sites. Eligible participants were generally healthy or had stable chronic conditions, without known SARS-CoV-2 infection in the previous 90 days. Individuals who were acutely ill or febrile 1 day before or at the screening visit or those who previously received other COVID-19 vaccines (except mRNA-1273 for part 2) were excluded. In part 1, SARS-CoV-2-vaccine-naive participants received two-dose mRNA-1273.214 (25 μg; omicron BA.1 and ancestral Wuhan-Hu-1 mRNA) primary series. In part 2, participants who previously completed the two-dose mRNA-1273 (25 μg) primary series in KidCOVE (NCT04796896) received a mRNA-1273.214 (10 μg) booster dose. Primary study outcomes were safety and reactogenicity of the mRNA-1273.214 primary series (part 1) or booster dose (part 2) as well as the inferred effectiveness of mRNA-1273.214 based on immune responses against ancestral SARS-CoV-2 (D614G) and omicron BA.1 variant at 28 days post-primary series (part 1) or post-booster dose (part 2). The safety set included participants who received at least one dose of the study vaccine; the immunogenicity set included those who provided immunogenicity samples. Interim safety and immunogenicity are summarised in this analysis as of the data cutoff date (Dec 5, 2022). This trial is registered with ClinicalTrials.gov, NCT05436834.
Between June 21, 2022, and Dec 5, 2022, 179 participants received one or more doses of mRNA-1273.214 primary series (part 1) and 539 received a mRNA-1273.214 booster dose (part 2). The safety profile within 28 days after either dose of the mRNA-1273.214 primary series and the booster dose was consistent with that of the mRNA-1273 primary series in this age group, with no new safety concerns or vaccine-related serious adverse events observed. At 28 days after primary series dose 2 and the booster dose, both mRNA-1273.214 primary series (day 57, including all participants with or without evidence of prior SARS-CoV-2 infection at baseline) and booster (day 29, including participants without evidence of prior SARS-CoV-2 infection at baseline) elicited responses that were superior against omicron-BA.1 (geometric mean ratio part 1: 25·4 [95% CI 20·1-32·1] and part 2: 12·5 [11·0-14·3]) and non-inferior against D614G (part 1: 0·8 [0·7-1·0] and part 2: 3·1 [2·8-3·5]), compared with neutralising antibody responses induced by the mRNA-1273 primary series (in a historical comparator group).
mRNA-1273.214 was immunogenic against BA.1 and D614G in children aged 6 months to 5 years, with a comparable safety profile to mRNA-1273, when given as a two-dose primary series or a booster dose. These results are aligned with the US Centers for Disease Control and Prevention recommendations for the use of variant-containing vaccines for continued protection against the emerging variants of SARS-CoV-2.
Moderna.
Dixit A
,Bennett R
,Ali K
,Griffin C
,Clifford RA
,Turner M
,Poston R
,Hautzinger K
,Yeakey A
,Girard B
,Zhou W
,Deng W
,Zhou H
,Schnyder Ghamloush S
,Kuter BJ
,Slobod K
,Miller JM
,Priddy F
,Das R
,ROVER Study Investigators
... -
《-》
-
Immunogenicity and safety of a bivalent (omicron BA.5 plus ancestral) SARS-CoV-2 recombinant spike protein vaccine as a heterologous booster dose: interim analysis of a phase 3, non-inferiority, randomised, clinical trial.
SARS-CoV-2 variants evade immunity despite vaccination with prototype COVID-19 vaccines or previous infection. The 2019nCoV-311 (part 2) study is evaluating immune responses after two booster doses of a vaccine containing the omicron BA.5 subvariant spike protein in adults previously vaccinated with a prototype mRNA vaccine. This interim analysis reports on day 28 immunogenicity and safety outcomes after one booster dose.
In this phase 3, randomised, observer-blinded study conducted at 35 sites in Australia, medically stable, previously COVID-19-vaccinated (mRNA-based; ≥three doses) adults aged 18 years or older were enrolled and randomly allocated (1:1:1; via an interactive web response system) to receive two doses of bivalent (NVX-CoV2373 + NVX-CoV2540; bivalent group), authorised prototype (NVX-CoV2373; prototype group), or BA.5 (NVX-CoV2540; BA.5 group) vaccine. Only blinded personnel performed study assessments or had participant contact to collect data after study vaccination. Participants received vaccines containing 5 μg SARS-CoV-2 recombinant spike protein and 50 μg Matrix-M adjuvant, administered via a 0·5 mL intramuscular injection (2·5 μg of NVX-CoV2373 plus 2·5 μg of NVX-CoV2540 for the bivalent vaccine, prepared on-site as a 1:1 mixture). The coprimary endpoints include day 28 neutralising antibody geometric mean titre (GMT) ratios (GMTRs) to omicron BA.5 and the ancestral strain, and seroresponse rates to BA.5, in the bivalent and prototype groups. These endpoints were calculated in the per-protocol analysis set, which was defined as participants who had received a vaccine dose, had baseline and day 28 immunogenicity data, and were PCR-negative for SARS-CoV-2, with no major protocol deviations. The primary objective was to determine the primary outcome (antibody responses), which consisted of three comparisons: superiority of the bivalent versus prototype vaccine for neutralising antibody GMT to BA.5 (ie, lower bound of the GMTR 95% CI >1·0); non-inferiority of neutralising antibody seroresponse rate to BA.5 (ie, lower bound of the seroresponse rate 95% CI >-5%); and non-inferiority of neutralising antibody GMT to the ancestral strain (ie, lower bound of GMTR 95% CI >0·67). This trial was registered at ClinicalTrials.gov, number NCT05372588.
Between March 22, 2023 and May 2, 2023, 837 participants were screened for eligibility and 766 were randomly allocated to receive the BA.5 (n=255), prototype (n=252), or bivalent (n=259) vaccine. After accounting for exclusions due to participants being baseline SARS-CoV-2-positive, having previous infection, or protocol deviations, the per-protocol analysis set included 694 participants (236 in BA.5 group, 227 in prototype group, and 231 in bivalent group). In this interim analysis (maximum follow-up 35 days after the first dose), the bivalent group, compared with the prototype group, had superior neutralising antibody responses to BA.5 (GMT 1017·8 [95% CI 891·0-1162·6] vs 515·1 [450·4-589·0]; GMTR 2·0 [1·69-2·33]) and a non-inferior seroresponse rate to BA.5 at day 28 (39·8% [33·5-46·5] vs 12·3% [8·4-17·3]; difference 27·5% [19·8-35·0]). The bivalent group also had non-inferior neutralising antibody responses to the ancestral strain (GMTR 1·0 [0·84-1·20]), compared with the prototype group. All vaccines were similarly well tolerated.
All three coprimary endpoints were met in part 2 of the ongoing 2019nCoV-311 study. These data support the development of monovalent and/or bivalent vaccines for the most currently circulating variants, to optimise protection. With no new safety findings, further investigation of omicron-based subvariant vaccines is supported by the evidence.
Novavax.
Bennett C
,Woo W
,Bloch M
,Cheung K
,Griffin P
,Mohan R
,Deshmukh S
,Arya M
,Cumming O
,Neville AM
,McCallum Pardey TG
,Plested JS
,Cloney-Clark S
,Zhu M
,Kalkeri R
,Patel N
,Marcheschi A
,Swan J
,Smith G
,Cho I
,Glenn GM
,Walker R
,Mallory RM
,Novavax 2019nCoV-311 Study Group
... -
《-》
-
Omicron BA.1-containing mRNA-1273 boosters compared with the original COVID-19 vaccine in the UK: a randomised, observer-blind, active-controlled trial.
The omicron BA.1 bivalent booster is used globally. Previous open-label studies of the omicron BA.1 (Moderna mRNA-1273.214) booster showed superior neutralising antibody responses against omicron BA.1 and other variants compared with the original mRNA-1273 booster. We aimed to compare the safety and immunogenicity of omicron BA.1 monovalent and bivalent boosters with the original mRNA-1273 vaccine in a large, randomised controlled trial.
In this large, randomised, observer-blind, active-controlled, phase 3 trial in the UK (28 hospital and vaccination clinic sites), individuals aged 16 years or older who had previously received two injections of any authorised or approved COVID-19 vaccine, with or without an mRNA vaccine booster (third dose), were randomly allocated (1:1) using interactive response technology to receive 50 μg omicron BA.1 monovalent or bivalent vaccines or 50 μg mRNA-1273 administered as boosters via deltoid intramuscular injection. The primary outcomes were safety and immunogenicity at day 29, including prespecified non-inferiority and superiority of booster immune responses, based on the neutralising antibody geometric mean concentration (GMC) ratios of the monovalent and bivalent boosters compared with mRNA-1273. Safety was assessed in all participants who received first or second boosters, and primary immunogenicity outcomes were assessed in all participants who received the planned booster dose, had pre-booster and day 29 antibody data, had no major protocol deviations, and who were SARS-CoV-2-negative. The study is registered with EudraCT (2022-000063-51) and ClinicalTrials.gov (NCT05249829) and is ongoing.
Between Feb 16 and March 24, 2022, 724 participants were randomly allocated to receive omicron BA.1 monovalent (n=366) or mRNA-1273 (n=357), and between April 2 and June 17, 2022, 2824 participants were randomly allocated to receive omicron BA.1 bivalent (n=1418) or mRNA-1273 (n=1395) vaccines as second boosters. Median durations (months) between the most recent COVID-19 vaccine and study boosters were similar for omicron BA.1 monovalent (4·0 months [IQR 3·6-4·7]) and mRNA-1273 (4·1 [3·5-4·7]), and for the omicron BA.1 bivalent (5·5 [4·8-6·2]) and mRNA-1273 (5·4 [4·8-6·2]) boosters. The omicron BA.1 monovalent and bivalent boosters elicited superior neutralising GMCs against the omicron BA.1 variant compared with mRNA-1273, with GMC ratios of 1·68 (99% CI 1·45-1·95) and 1·53 (1·41-1·67) at day 29 post-booster doses in participants without previous SARS-CoV-2 infection. Both boosters induced non-inferior ancestral SARS-CoV-2 (Asp614Gly) immune responses with GMCs that were similar for the bivalent (2987·2 [95% CI 2814·9-3169·9]) versus mRNA-1273 (2911·3 [2750·9-3081·0]) and lower for the monovalent (2699·7 [2431·3-2997·7] vs 3020·6 [2776·5-3286·2]) boosters, with respective GMC ratios of 1·05 (99% CI 0·96-1·15) and 0·82 (95% CI 0·74-0·91). Results were comparable regardless of previous SARS-CoV-2 infection status. Incidences of solicited adverse reactions with the omicron BA.1 monovalent (335 [91·3%] of 367 participants) and omicron BA.1 bivalent (1285 [90·4%] of 1421 participants) boosters were similar to those observed previously for mRNA-1273, with no new safety concerns identified and no occurrences of fatal adverse events.
Omicron-containing booster vaccines generated superior immunogenicity against omicron BA.1 and comparable immunogenicity against the original strain with no new safety concerns. It remains important to continuously monitor the immune responses and real-world vaccine effectiveness as divergent SARS-CoV-2 variants emerge.
Moderna.
Lee IT
,Cosgrove CA
,Moore P
,Bethune C
,Nally R
,Bula M
,Kalra PA
,Clark R
,Dargan PI
,Boffito M
,Sheridan R
,Moran E
,Darton TC
,Burns F
,Saralaya D
,Duncan CJA
,Lillie PJ
,San Francisco Ramos A
,Galiza EP
,Heath PT
,Girard B
,Parker C
,Rust D
,Mehta S
,de Windt E
,Sutherland A
,Tomassini JE
,Dutko FJ
,Chalkias S
,Deng W
,Chen X
,Feng J
,Tracy L
,Zhou H
,Miller JM
,Das R
,Study Investigators
... -
《-》
-
Immunogenicity and safety of a booster dose of a self-amplifying RNA COVID-19 vaccine (ARCT-154) versus BNT162b2 mRNA COVID-19 vaccine: a double-blind, multicentre, randomised, controlled, phase 3, non-inferiority trial.
Oda Y
,Kumagai Y
,Kanai M
,Iwama Y
,Okura I
,Minamida T
,Yagi Y
,Kurosawa T
,Greener B
,Zhang Y
,Walson JL
... -
《-》
-
A Bivalent Omicron-Containing Booster Vaccine against Covid-19.
The safety and immunogenicity of the bivalent omicron-containing mRNA-1273.214 booster vaccine are not known.
In this ongoing, phase 2-3 study, we compared the 50-μg bivalent vaccine mRNA-1273.214 (25 μg each of ancestral Wuhan-Hu-1 and omicron B.1.1.529 [BA.1] spike messenger RNAs) with the previously authorized 50-μg mRNA-1273 booster. We administered mRNA-1273.214 or mRNA-1273 as a second booster in adults who had previously received a two-dose (100-μg) primary series and first booster (50-μg) dose of mRNA-1273 (≥3 months earlier). The primary objectives were to assess the safety, reactogenicity, and immunogenicity of mRNA-1273.214 at 28 days after the booster dose.
Interim results are presented. Sequential groups of participants received 50 μg of mRNA-1273.214 (437 participants) or mRNA-1273 (377 participants) as a second booster dose. The median time between the first and second boosters was similar for mRNA-1273.214 (136 days) and mRNA-1273 (134 days). In participants with no previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, the geometric mean titers of neutralizing antibodies against the omicron BA.1 variant were 2372.4 (95% confidence interval [CI], 2070.6 to 2718.2) after receipt of the mRNA-1273.214 booster and 1473.5 (95% CI, 1270.8 to 1708.4) after receipt of the mRNA-1273 booster. In addition, 50-μg mRNA-1273.214 and 50-μg mRNA-1273 elicited geometric mean titers of 727.4 (95% CI, 632.8 to 836.1) and 492.1 (95% CI, 431.1 to 561.9), respectively, against omicron BA.4 and BA.5 (BA.4/5), and the mRNA-1273.214 booster also elicited higher binding antibody responses against multiple other variants (alpha, beta, gamma, and delta) than the mRNA-1273 booster. Safety and reactogenicity were similar with the two booster vaccines. Vaccine effectiveness was not assessed in this study; in an exploratory analysis, SARS-CoV-2 infection occurred in 11 participants after the mRNA-1273.214 booster and in 9 participants after the mRNA-1273 booster.
The bivalent omicron-containing vaccine mRNA-1273.214 elicited neutralizing antibody responses against omicron that were superior to those with mRNA-1273, without evident safety concerns. (Funded by Moderna; ClinicalTrials.gov number, NCT04927065.).
Chalkias S
,Harper C
,Vrbicky K
,Walsh SR
,Essink B
,Brosz A
,McGhee N
,Tomassini JE
,Chen X
,Chang Y
,Sutherland A
,Montefiori DC
,Girard B
,Edwards DK
,Feng J
,Zhou H
,Baden LR
,Miller JM
,Das R
... -
《-》