-
Immunogenicity and safety of a bivalent (omicron BA.5 plus ancestral) SARS-CoV-2 recombinant spike protein vaccine as a heterologous booster dose: interim analysis of a phase 3, non-inferiority, randomised, clinical trial.
SARS-CoV-2 variants evade immunity despite vaccination with prototype COVID-19 vaccines or previous infection. The 2019nCoV-311 (part 2) study is evaluating immune responses after two booster doses of a vaccine containing the omicron BA.5 subvariant spike protein in adults previously vaccinated with a prototype mRNA vaccine. This interim analysis reports on day 28 immunogenicity and safety outcomes after one booster dose.
In this phase 3, randomised, observer-blinded study conducted at 35 sites in Australia, medically stable, previously COVID-19-vaccinated (mRNA-based; ≥three doses) adults aged 18 years or older were enrolled and randomly allocated (1:1:1; via an interactive web response system) to receive two doses of bivalent (NVX-CoV2373 + NVX-CoV2540; bivalent group), authorised prototype (NVX-CoV2373; prototype group), or BA.5 (NVX-CoV2540; BA.5 group) vaccine. Only blinded personnel performed study assessments or had participant contact to collect data after study vaccination. Participants received vaccines containing 5 μg SARS-CoV-2 recombinant spike protein and 50 μg Matrix-M adjuvant, administered via a 0·5 mL intramuscular injection (2·5 μg of NVX-CoV2373 plus 2·5 μg of NVX-CoV2540 for the bivalent vaccine, prepared on-site as a 1:1 mixture). The coprimary endpoints include day 28 neutralising antibody geometric mean titre (GMT) ratios (GMTRs) to omicron BA.5 and the ancestral strain, and seroresponse rates to BA.5, in the bivalent and prototype groups. These endpoints were calculated in the per-protocol analysis set, which was defined as participants who had received a vaccine dose, had baseline and day 28 immunogenicity data, and were PCR-negative for SARS-CoV-2, with no major protocol deviations. The primary objective was to determine the primary outcome (antibody responses), which consisted of three comparisons: superiority of the bivalent versus prototype vaccine for neutralising antibody GMT to BA.5 (ie, lower bound of the GMTR 95% CI >1·0); non-inferiority of neutralising antibody seroresponse rate to BA.5 (ie, lower bound of the seroresponse rate 95% CI >-5%); and non-inferiority of neutralising antibody GMT to the ancestral strain (ie, lower bound of GMTR 95% CI >0·67). This trial was registered at ClinicalTrials.gov, number NCT05372588.
Between March 22, 2023 and May 2, 2023, 837 participants were screened for eligibility and 766 were randomly allocated to receive the BA.5 (n=255), prototype (n=252), or bivalent (n=259) vaccine. After accounting for exclusions due to participants being baseline SARS-CoV-2-positive, having previous infection, or protocol deviations, the per-protocol analysis set included 694 participants (236 in BA.5 group, 227 in prototype group, and 231 in bivalent group). In this interim analysis (maximum follow-up 35 days after the first dose), the bivalent group, compared with the prototype group, had superior neutralising antibody responses to BA.5 (GMT 1017·8 [95% CI 891·0-1162·6] vs 515·1 [450·4-589·0]; GMTR 2·0 [1·69-2·33]) and a non-inferior seroresponse rate to BA.5 at day 28 (39·8% [33·5-46·5] vs 12·3% [8·4-17·3]; difference 27·5% [19·8-35·0]). The bivalent group also had non-inferior neutralising antibody responses to the ancestral strain (GMTR 1·0 [0·84-1·20]), compared with the prototype group. All vaccines were similarly well tolerated.
All three coprimary endpoints were met in part 2 of the ongoing 2019nCoV-311 study. These data support the development of monovalent and/or bivalent vaccines for the most currently circulating variants, to optimise protection. With no new safety findings, further investigation of omicron-based subvariant vaccines is supported by the evidence.
Novavax.
Bennett C
,Woo W
,Bloch M
,Cheung K
,Griffin P
,Mohan R
,Deshmukh S
,Arya M
,Cumming O
,Neville AM
,McCallum Pardey TG
,Plested JS
,Cloney-Clark S
,Zhu M
,Kalkeri R
,Patel N
,Marcheschi A
,Swan J
,Smith G
,Cho I
,Glenn GM
,Walker R
,Mallory RM
,Novavax 2019nCoV-311 Study Group
... -
《-》
-
Immunogenicity and Safety of Heterologous Omicron BA.1 and Bivalent SARS-CoV-2 Recombinant Spike Protein Booster Vaccines: A Phase 3 Randomized Clinical Trial.
Mutations present in emerging SARS-CoV-2 variants permit evasion of neutralization with prototype vaccines. A novel Omicron BA.1 subvariant-specific vaccine (NVX-CoV2515) was tested alone or as a bivalent preparation with the prototype vaccine (NVX-CoV2373) to assess antibody responses to SARS-CoV-2.
Participants aged 18 to 64 years immunized with 3 doses of prototype mRNA vaccines were randomized 1:1:1 to receive a single dose of NVX-CoV2515, NVX-CoV2373, or the bivalent mixture in a phase 3 study investigating heterologous boosting with SARS-CoV-2 recombinant spike protein vaccines. Immunogenicity was measured 14 and 28 days after vaccination for the SARS-CoV-2 Omicron BA.1 sublineage and ancestral strain. Safety profiles of vaccines were assessed.
Of participants who received trial vaccine (N = 829), those administered NVX-CoV2515 (n = 286) demonstrated a superior neutralizing antibody response to BA.1 vs NVX-CoV2373 (n = 274) at day 14 (geometric mean titer ratio, 1.6; 95% CI, 1.33-2.03). Seroresponse rates were 73.4% (91/124; 95% CI, 64.7-80.9) for NVX-CoV2515 vs 50.9% (59/116; 95% CI, 41.4-60.3) for NVX-CoV2373. All formulations were similarly well tolerated.
NVX-CoV2515 elicited a superior neutralizing antibody response against the Omicron BA.1 subvariant as compared with NVX-CoV2373 when administered as a fourth dose. Safety data were consistent with the established safety profile of NVX-CoV2373.
ClinicalTrials.gov (NCT05372588).
Bennett C
,Rivers EJ
,Woo W
,Bloch M
,Cheung K
,Griffin P
,Mohan R
,Deshmukh S
,Arya M
,Cumming O
,Neville AM
,Pardey TM
,Plested JS
,Cloney-Clark S
,Zhu M
,Kalkeri R
,Patel N
,Buchanan A
,Marcheschi A
,Swan J
,Smith G
,Cho I
,Glenn GM
,Walker R
,Mallory RM
... -
《-》
-
Safety and immunogenicity following a homologous booster dose of a SARS-CoV-2 recombinant spike protein vaccine (NVX-CoV2373): a secondary analysis of a randomised, placebo-controlled, phase 2 trial.
Emerging SARS-CoV-2 variants and evidence of waning vaccine efficacy present substantial obstacles towards controlling the COVID-19 pandemic. Booster doses of SARS-CoV-2 vaccines might address these concerns by amplifying and broadening the immune responses seen with initial vaccination regimens. We aimed to assess the immunogenicity and safety of a homologous booster dose of a SARS-CoV-2 recombinant spike protein vaccine (NVX-CoV2373).
This secondary analysis of a phase 2, randomised study assessed a single booster dose of a SARS-CoV-2 recombinant spike protein vaccine with Matrix-M adjuvant (NVX-CoV2373) in healthy adults aged 18-84 years, recruited from 17 clinical centres in the USA and Australia. Eligible participants had a BMI of 17-35 kg/m2 and, for women, were heterosexually inactive or using contraception. Participants who had a history of SARS-CoV or SARS-CoV-2, confirmed diagnosis of COVID-19, serious chronic medical conditions, or were pregnant or breastfeeding were excluded. Approximately 6 months following their primary two-dose vaccination series (administered day 0 and day 21), participants who received placebo for their primary vaccination series received a placebo booster (group A) and participants who received NVX-CoV2373 for their primary vaccination series (group B) were randomly assigned (1:1) again, via centralised interactive response technology system, to receive either placebo (group B1) or a single booster dose of NVX-CoV2373 (5 μg SARS-CoV-2 rS with 50 μg Matrix-M adjuvant; group B2) via intramuscular injection; randomisation was stratified by age and study site. Vaccinations were administered by designated site personnel who were masked to treatment assignment, and participants and other site staff were also masked. Administration personnel also assessed the outcome. The primary endpoints are safety (unsolicited adverse events) and reactogenicity (solicited local and systemic) events and immunogenicity (serum IgG antibody concentrations for the SARS-CoV-2 rS protein antigen) assessed 14 days after the primary vaccination series (day 35) and 28 days following booster (day 217). Safety was analysed in all participants in groups A, B1, and B2, according to the treatment received; immunogenicity was analysed in the per-protocol population (ie, participants in groups A, B1, and B2) who received all assigned doses and who did not test SARS-CoV-2-positive or received an authorised vaccine, analysed according to treatment assignment). This trial is registered with ClinicalTrials.gov, NCT04368988.
1610 participants were screened from Aug 24, 2020, to Sept 25, 2020. 1282 participants were enrolled, of whom 173 were assigned again to placebo (group A), 106 were re-randomised to NVX-CoV2373-placebo (group B1), and 104 were re-randomised to NVX-CoV2373-NVX-CoV2373 (group B2); after accounting for exclusions and incorrect administration, 172 participants in group A, 102 in group B1, and 105 in group B2 were analysed for safety. Following the active booster, the proportion of participants with available data reporting local (80 [82%] of 97 participants had any adverse event; 13 [13%] had a grade ≥3 event) and systemic (75 [77%] of 98 participants had any adverse event; 15 [15%] had a grade ≥3 event) reactions was higher than after primary vaccination (175 [70%] of 250 participants had any local adverse event, 13 [5%] had a grade ≥3 event; 132 [53%] of 250 had any systemic adverse event, 14 [6%] had a grade ≥3 event). Local and systemic events were transient in nature (median duration 1·0-2·5 days). In the per-protocol immunogenicity population at day 217 (167 participants in group A, 101 participants in group B1, 101 participants in group B2), IgG geometric mean titres (GMT) had increased by 4·7-fold and MN50 GMT by 4·1-fold for the ancestral SARS-CoV-2 strain compared with the day 35 titres.
Administration of a booster dose of NVX-CoV2373 resulted in an incremental increase in reactogenicity. For both the prototype strain and all variants evaluated, immune responses following the booster were similar to or higher than those associated with high levels of efficacy in phase 3 studies of the vaccine. These data support the use of NVX-CoV2373 in booster programmes.
Novavax and the Coalition for Epidemic Preparedness Innovations.
Mallory RM
,Formica N
,Pfeiffer S
,Wilkinson B
,Marcheschi A
,Albert G
,McFall H
,Robinson M
,Plested JS
,Zhu M
,Cloney-Clark S
,Zhou B
,Chau G
,Robertson A
,Maciejewski S
,Hammond HL
,Baracco L
,Logue J
,Frieman MB
,Smith G
,Patel N
,Glenn GM
,Novavax 2019nCoV101 Study Group
... -
《-》
-
Omicron BA.1-containing mRNA-1273 boosters compared with the original COVID-19 vaccine in the UK: a randomised, observer-blind, active-controlled trial.
The omicron BA.1 bivalent booster is used globally. Previous open-label studies of the omicron BA.1 (Moderna mRNA-1273.214) booster showed superior neutralising antibody responses against omicron BA.1 and other variants compared with the original mRNA-1273 booster. We aimed to compare the safety and immunogenicity of omicron BA.1 monovalent and bivalent boosters with the original mRNA-1273 vaccine in a large, randomised controlled trial.
In this large, randomised, observer-blind, active-controlled, phase 3 trial in the UK (28 hospital and vaccination clinic sites), individuals aged 16 years or older who had previously received two injections of any authorised or approved COVID-19 vaccine, with or without an mRNA vaccine booster (third dose), were randomly allocated (1:1) using interactive response technology to receive 50 μg omicron BA.1 monovalent or bivalent vaccines or 50 μg mRNA-1273 administered as boosters via deltoid intramuscular injection. The primary outcomes were safety and immunogenicity at day 29, including prespecified non-inferiority and superiority of booster immune responses, based on the neutralising antibody geometric mean concentration (GMC) ratios of the monovalent and bivalent boosters compared with mRNA-1273. Safety was assessed in all participants who received first or second boosters, and primary immunogenicity outcomes were assessed in all participants who received the planned booster dose, had pre-booster and day 29 antibody data, had no major protocol deviations, and who were SARS-CoV-2-negative. The study is registered with EudraCT (2022-000063-51) and ClinicalTrials.gov (NCT05249829) and is ongoing.
Between Feb 16 and March 24, 2022, 724 participants were randomly allocated to receive omicron BA.1 monovalent (n=366) or mRNA-1273 (n=357), and between April 2 and June 17, 2022, 2824 participants were randomly allocated to receive omicron BA.1 bivalent (n=1418) or mRNA-1273 (n=1395) vaccines as second boosters. Median durations (months) between the most recent COVID-19 vaccine and study boosters were similar for omicron BA.1 monovalent (4·0 months [IQR 3·6-4·7]) and mRNA-1273 (4·1 [3·5-4·7]), and for the omicron BA.1 bivalent (5·5 [4·8-6·2]) and mRNA-1273 (5·4 [4·8-6·2]) boosters. The omicron BA.1 monovalent and bivalent boosters elicited superior neutralising GMCs against the omicron BA.1 variant compared with mRNA-1273, with GMC ratios of 1·68 (99% CI 1·45-1·95) and 1·53 (1·41-1·67) at day 29 post-booster doses in participants without previous SARS-CoV-2 infection. Both boosters induced non-inferior ancestral SARS-CoV-2 (Asp614Gly) immune responses with GMCs that were similar for the bivalent (2987·2 [95% CI 2814·9-3169·9]) versus mRNA-1273 (2911·3 [2750·9-3081·0]) and lower for the monovalent (2699·7 [2431·3-2997·7] vs 3020·6 [2776·5-3286·2]) boosters, with respective GMC ratios of 1·05 (99% CI 0·96-1·15) and 0·82 (95% CI 0·74-0·91). Results were comparable regardless of previous SARS-CoV-2 infection status. Incidences of solicited adverse reactions with the omicron BA.1 monovalent (335 [91·3%] of 367 participants) and omicron BA.1 bivalent (1285 [90·4%] of 1421 participants) boosters were similar to those observed previously for mRNA-1273, with no new safety concerns identified and no occurrences of fatal adverse events.
Omicron-containing booster vaccines generated superior immunogenicity against omicron BA.1 and comparable immunogenicity against the original strain with no new safety concerns. It remains important to continuously monitor the immune responses and real-world vaccine effectiveness as divergent SARS-CoV-2 variants emerge.
Moderna.
Lee IT
,Cosgrove CA
,Moore P
,Bethune C
,Nally R
,Bula M
,Kalra PA
,Clark R
,Dargan PI
,Boffito M
,Sheridan R
,Moran E
,Darton TC
,Burns F
,Saralaya D
,Duncan CJA
,Lillie PJ
,San Francisco Ramos A
,Galiza EP
,Heath PT
,Girard B
,Parker C
,Rust D
,Mehta S
,de Windt E
,Sutherland A
,Tomassini JE
,Dutko FJ
,Chalkias S
,Deng W
,Chen X
,Feng J
,Tracy L
,Zhou H
,Miller JM
,Das R
,Study Investigators
... -
《-》
-
Immunogenicity and safety of a booster dose of a self-amplifying RNA COVID-19 vaccine (ARCT-154) versus BNT162b2 mRNA COVID-19 vaccine: a double-blind, multicentre, randomised, controlled, phase 3, non-inferiority trial.
Oda Y
,Kumagai Y
,Kanai M
,Iwama Y
,Okura I
,Minamida T
,Yagi Y
,Kurosawa T
,Greener B
,Zhang Y
,Walson JL
... -
《-》