Baveno VII algorithm outperformed other models in ruling out high-risk varices in individuals with HBV-related cirrhosis.
摘要:
The Baveno VII consensus recommends that spleen stiffness measurement (SSM) ≤40 kPa is safe for ruling out high-risk varices (HRVs) and avoiding endoscopic screening in patients who do not meet the Baveno VI criteria. This study aimed to validate the performance of the Baveno VII algorithm in individuals with HBV-related cirrhosis. Consecutive individuals with HBV-related cirrhosis who underwent liver stiffness measurement (LSM) and SSM - using a 50 Hz shear wave frequency, spleen diameter measurement, and esophagogastroduodenoscopy (EGD) were prospectively enrolled from June 2020. A 100 Hz probe has been adopted for additional SSM assessment since July 2021. From June 2020 to January 2022, 996 patients were screened and 504 were enrolled for analysis. Among the 504 patients in whom SSM was assessed using a 50 Hz probe, the Baveno VII algorithm avoided more EGDs (56.7% vs. 39.1%, p <0.001) than Baveno VI criteria, with a comparable missed HRV rate (3.8% vs. 2.5%). Missed HRV rates were >5% for all other measures: 11.3% for LSM-longitudinal spleen diameter to platelet ratio score, 20.0% for platelet count/longitudinal spleen diameter ratio, and 8.8% for Rete Sicilia Selezione Terapia-hepatitis. SSM@100 Hz was assessed in 232 patients, and the Baveno VII algorithm with SSM@100 Hz spared more EGDs (75.4% vs. 59.5%, p <0.001) than that with SSM@50 Hz, both with a missed HRV rate of 3.0% (1/33). We validated the Baveno VII algorithm, demonstrating the excellent performance of SSM@50 Hz and SSM@100 Hz in ruling out HRV in individuals with HBV-related cirrhosis. Furthermore, the Baveno VII algorithm with SSM@100 Hz could safely rule out more EGDs than that with SSM@50 Hz. NCT04890730. The Baveno VII guideline proposed that for patients who do not meet the Baveno VI criteria, SSM ≤40 kPa could avoid further unnecessary endoscopic screening. The current study validated the Baveno VII algorithm using 50 Hz and 100 Hz probes, which both exhibited excellent performance in ruling out HRVs in individuals with HBV-related cirrhosis. Compared with the Baveno VII algorithm with SSM@50 Hz, SSM@100 Hz had a better capability to safely rule out unnecessary EGDs. Baveno VII algorithm will be a practical tool to triage individuals with cirrhosis in future clinical practice.
收起
展开
DOI:
10.1016/j.jhep.2022.10.030
被引量:
年份:
1970


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(117)
参考文献(0)
引证文献(6)
来源期刊
影响因子:暂无数据
JCR分区: 暂无
中科院分区:暂无