Cema-based formalism for the determination of absorbed dose for high-energy photon beams.

来自 PUBMED

作者:

Hartmann GHAndreo PKapsch RPZink K

展开

摘要:

Determination of absorbed dose is well established in many dosimetry protocols and considered to be highly reliable using ionization chambers under reference conditions. If dosimetry is performed under other conditions or using other detectors, however, open questions still remain. Such questions frequently refer to appropriate correction factors. A converted energy per mass (cema)-based approach to formulate such correction factors offers a good understanding of the specific response of a detector for dosimetry under various measuring conditions and thus an estimate of pros and cons of its application. Determination of absorbed dose requires the knowledge of the beam quality correction factor kQ,Qo , where Q denotes the quality of a user beam and Qo is the quality of the radiation used for calibration. In modern Monte Carlo (MC)-based methods, kQ,Qo is directly derived from the MC-calculated dose conversion factor, which is the ratio between the absorbed dose at a point of interest in water and the mean absorbed dose in the sensitive volume of an ion chamber. In this work, absorbed dose is approximated by the fundamental quantity cema. This approximation allows the dose conversion factor to be substituted by the cema conversion factor. Subsequently, this factor is decomposed into a product of cema ratios. They are identified as the stopping power ratio water to the material in the sensitive detector volume, and as the correction factor for the fluence perturbation of the secondary charged particles in the detector cavity caused by the presence of the detector. This correction factor is further decomposed with respect to the perturbation caused by the detector cavity and that caused by external detector properties. The cema-based formalism was subsequently tested by MC calculations of the spectral fluence of the secondary charged particles (electrons and positrons) under various conditions. MC calculations demonstrate that considerable fluence perturbation may occur particularly under non-reference conditions. Cema-based correction factors to be applied in a 6-MV beam were obtained for a number of ionization chambers and for three solid-state detectors. Feasibility was shown at field sizes of 4 × 4 and 0.5 cm × 0.5 cm. Values of the cema ratios resulting from the decomposition of the dose conversion factor can be well correlated with detector response. Under the small field conditions, the internal fluence correction factor of ionization chambers is considerably dependent on volume averaging and thus on the shape and size of the cavity volume. The cema approach is particularly useful at non-reference conditions including when solid-state detectors are used. Perturbation correction factors can be expressed and evaluated by cema ratios in a comprehensive manner. The cema approach can serve to understand the specific response of a detector for dosimetry to be dependent on (a) radiation quality, (b) detector properties, and (c) electron fluence changes caused by the detector. This understanding may also help to decide which detector is best suited for a specific measurement situation.

收起

展开

DOI:

10.1002/mp.15266

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(240)

参考文献(0)

引证文献(2)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读