A Monte Carlo study on the PTW 60019 microDiamond detector.

来自 PUBMED

作者:

Hartmann GHZink K

展开

摘要:

Data on the output correction factor for small photon beam dosimetry of the microDiamond detector manufactured by the company PTW can be found in a variety of papers. Referring either to measurements or to Monte Carlo (MC) calculations, they show substantial disagreements particularly at very small fields. This work reports results of a further MC study aiming at a better understanding of how specific properties of the microDiamond detector are influencing its output correction factor and whether this can explain at least some of the disagreements. In this study the method of a fluence-based decomposition of the dose conversion factor was used which is considered as a useful tool to understand the response of a detector in nonreference conditions. This decomposition method yields the following three factors: (a) the stopping power ratio water to diamond, (b) a perturbation factor pint taking into account all fluence changes in the transition from a small water voxel at the point of dose determination to the bare diamond detector, and (c) a perturbation factor pext taking into account all additional fluence changes in the fully simulated diamond detector caused by the material and design details outside the sensitive volume. Monte Carlo calculated output correction factors were obtained for Co-60, 6 MV and 10 MV photon beams showing that the maximum variation with field size remained in the order of 2% for quadratic field sizes larger than about 0.3 cm. For field sizes smaller than about 0.5 cm a clear under-response is obtained at all three radiation qualities in agreement with all known MC calculations, however, in contrast to some measured result. The shape of the output correction factor can be well explained by an opposite mode of action between under-response expressed by the perturbation factor pint and over-response expressed by the perturbation factor pext where the first one is mainly influenced by volume averaging, and the second one by a back scatter effect of electrons from the diamond substrate into the sensitive volume. The response of microDiamond detector can be well described under various measuring conditions by the dose conversion factor and the dependency of its fluence-based subfactors on detector characteristics. Monte Carlo simulations offer an improvement in the understanding particularly of small-field effects by relating the output correction factor to spectral fluence changes in the sensitive volume of the detector. The most significant influence factors are the finite size of the active volume and the presence of the high-density diamond substrate causing a field size-dependent backscattering. These perturbations are opposite in their effects. The diamond in the sensitive volume itself and in particular its density has almost no influence. Scattering of results at very small field sizes can be explained by different gradients of dose profiles around the beam axis at identical full width half maximum (FWHM) field size parameters and by possible deviations of the radius of the sensitive volume from the nominal radius. The backscattering effect also has an influence on the determination of profiles and for very small field sizes on the response at different rotation angles.

收起

展开

DOI:

10.1002/mp.13721

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(392)

参考文献(0)

引证文献(2)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读