Dose perturbation caused by metallic port in breast tissue expander in proton beam therapy.

来自 PUBMED

作者:

Zhao LMoskvin VPCheng CWDas IJ

展开

摘要:

Proton beam treatment is being looked favourably now in breast treatment. Tissue expanders are often placed after mastectomy that contains metallic port for saline injection which produces dose perturbations in proton beam therapy with uncertain dosimetry. Dose perturbation for a stainless-steel injection port from a breast implant is investigated in this study. Measurements, Monte-Carlo simulation, and calculated dose distribution of plans based on kVCT and MVCT images are compared. Treatment plans are performed on kVCT and MVCT images to observe the effect of metal artifact from the breast implant. The kVCT based plan underestimates the beam range due to the overestimated water equivalent thickness of the metal ports as a result of image degradation. Compared to the measurement with metal port in the proton beam, the MVCT-based treatment planning provides more accurate dose calculation than the kVCT-based results. The dose perturbation factor calculated from MVCT planning is within 10% of the measurement results while HU corrected kVCT plan still shows dose difference as large as 100% due to the incorrect range pull back calculation caused by the misrepresentation of the volume between the plastic cap and the stainless-steel base. The dose enhancement observed at the metal and solid water interface is as large as 15%, which needs to be accounted for in the planning process if there is a clinical concern. Dose reduction as large as 16% is observed with depth from 1 cm to 4 cm underneath the thickest part of the metallic port whereas lateral dose perturbation is also seen up to 7 mm. The measurement data are supported by the Monte-Carlo simulated results with a maximum dose difference of 6%. It is concluded that if proton beam is used with metallic port, MVCT imaging data is recommended. In lieu of MVCT, DECT, CT scanner with metal artifact reduction software or in the very least, extended HU range should be used to reduce the streaking artifact as well as to produce a more accurate image of the metallic port.

收起

展开

DOI:

10.1088/2057-1976/abc899

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(119)

参考文献(0)

引证文献(0)

来源期刊

Biomedical Physics & Engineering Express

影响因子:0

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读