摘要:

To achieve a superior balance between dosimetry and the delivery efficiency of intensity-modulated proton therapy (IMPT) using as few beams as possible in a single fraction, we optimally vary beams in different fractions. In the optimization, 400~800 feasible noncoplanar beams were included in the candidate pool. For each beam, the doses of all scanning spots covering the target volume and a margin were calculated. The fraction-variant beam orientation optimization (FVBOO) problem was formulated to include three terms: two quadratic dose fidelity terms to penalize the deviation of planning target volume fractional dose and organs at risk (OAR) cumulative doses from prescription, respectively; an L2,1/2-norm group sparsity term to control the number of active beams per fraction to between 1 and 4. The Fast Iterative Shrinkage-Thresholding Algorithm (FISTA) was applied to solve this problem. FVBOO was tested on a patient with base-of-skull (BOS) tumor of 5 fractions (5f) and 30 fractions (30f) with an average number of active beams per fraction varying between 4 and 1. In addition, one bilateral head-and-neck (H&N) patient, and one esophageal cancer (ESG) patient of 30f were tested with about three active beams per fraction. The results were compared with IMPT plans that use fixed beams in each fraction. The fixed beams were selected using the group sparsity term with a fraction-invariant BOO (FIBOO) constraint. Varying beams were chosen in either the 5f or 30f FVBOO plans. While similar number of beams per fraction was selected as the FIBOO plan, the FVBOO plans were able to spare the OARs better, with an average reduction of [Dmean, Dmax] from the FIBOO plans by [0.85, 2.08] Relative Biological Effective Gy (GyRBE) in the 5f plan and [1.87, 4.06] GyRBE in the 30f plans. While reducing the number of beams per fraction in the BOS patient, a three-beam/fraction 5f FVBOO plan performs comparably as the four-beam FIBOO plan and a two-beam/fraction 30f FVBOO plan still provides superior dosimetry. Fraction-variant beam orientation optimization allows the utilization of a larger beam solution space for superior dose distribution in IMPT while maintaining a practical number of beams in each fraction.

收起

展开

DOI:

10.1002/mp.14340

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(112)

参考文献(31)

引证文献(2)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读