A novel energy layer optimization framework for spot-scanning proton arc therapy.

来自 PUBMED

作者:

Gu WRuan DLyu QZou WDong LSheng K

展开

摘要:

Spot-scanning proton arc therapy (SPAT) is an emerging modality to improve plan conformality and delivery efficiency. A greedy and heuristic method is proposed in the existing SPAT algorithm to select energy layers and sequence energy switching with gantry rotation, which does not promise optimality in either dosimetry or efficiency. We aim to develop a method to solve the energy layer switching and dosimetry optimization problems in an integrated framework for SPAT. In an integrated approach, energy layer optimization for spot-scanning proton arc therapy (ELO-SPAT) is formulated with a dose fidelity term, a group sparsity regularization, a log barrier regularization, and an energy sequencing (ES) penalty. The combination of L2,1/2-norm group sparsity regularization and log barrier function allows one energy layer being selected per control point. The ES regularization term sorts the delivery sequence from high energy to low energy to reduce the total energy layer switching time (ELST) and subsequently the total delivery time. Within the ES penalty, the gradient of layer weights between adjacent beams is first calculated along beam direction and then along energy direction. The gradients indicate energy switch patterns between two adjacent beams. The time-wise costly energy switch-up is more heavily penalized in the ES term. This ELO-SPAT method was tested on one frontal base-of-skull (BOS) patient, one chordoma (CHDM) patient with a simultaneous integrated boost, one bilateral head-and-neck (H&N) patient, and one lung (LNG) patient. We compared ELO-SPAT with intensity-modulated proton therapy (IMPT) using discrete beams and SPArc by Ding et al. For the two arc algorithms, both the plans with and without energy sequencing were created and compared. Energy layer optimization for spot-scanning proton arc therapy reduced the runtime of optimization by 84% on average compared with the greedy SPArc method. In both the ELO-SPAT plans with and without ES, one energy layer per control point was selected. Without ES regularization, the energy sequence was arbitrary, with around 40-60 switch-up for the tested cases. After adding ES regularization, the number of energy switch-up was reduced to less than 20. Compared with the energy sequenced SPArc plans, the ELO-SPAT plans with ES led to 24% less total ELST for synchrotron plans and 14% less for cyclotron plans. Both the ELO-SPAT and SPArc plans achieved better sparing compared with the IMPT plans for most Organs-at-risks (OARs), with or without ES. Without ES, the ELO-SPAT plans achieved further improvement of the OARs compared with the SPArc plans, with an averaged reduction of OAR [Dmean, Dmax] by [1.57, 3.34] GyRBE. Adding the ES regularization degraded the plan quality, but the ELO-SPAT plans still had comparable or slightly better sparing than the SPArc plans with ES, with an averaged reduction of OAR [Dmean, Dmax] by [1.42, 2.34] GyRBE. We developed a computationally efficient spot-scanning proton arc optimization method, which solved energy layer selection and sequencing in an integrated framework, generating plans with good dosimetry and high delivery efficiency.

收起

展开

DOI:

10.1002/mp.14083

被引量:

12

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(185)

参考文献(26)

引证文献(12)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读