A novel, yet simple MLC-based 3D-crossfire technique for spatially fractionated GRID therapy treatment of deep-seated bulky tumors.

来自 PUBMED

作者:

Pokhrel DHalfman MSanford LChen QKudrimoti M

展开

摘要:

Treating deep-seated bulky tumors with traditional single-field Cerrobend GRID-blocks has many limitations such as suboptimal target coverage and excessive skin toxicity. Heavy traditional GRID-blocks are a concern for patient safety at various gantry-angles and dosimetric detail is not always available without a GRID template in user's treatment planning system. Herein, we propose a simple, yet clinically useful multileaf collimator (MLC)-based three-dimensional (3D)-crossfire technique to provide sufficient target coverage, reduce skin dose, and potentially escalate tumor dose to deep-seated bulky tumors. Thirteen patients (multiple sites) who underwent conventional single-field cerrobend GRID-block therapy (maximum, 15 Gy in 1 fraction) were re-planned using an MLC-based 3D-crossfire method. Gross tumor volume (GTV) was used to generate a lattice pattern of 10 mm diameter and 20 mm center-to-center mimicking conventional GRID-block using an in-house MATLAB program. For the same prescription, MLC-based 3D-crossfire grid plans were generated using 6-gantry positions (clockwise) at 60° spacing (210°, 270°, 330°, 30°, 90°, 150°, therefore, each gantry angle associated with a complement angle at 180° apart) with differentially-weighted 6 or 18 MV beams in Eclipse. For each gantry, standard Millenium120 (Varian) 5 mm MLC leaves were fit to the grid-pattern with 90° collimator rotation, so that the tunneling dose distribution was achieved. Acuros-based dose was calculated for heterogeneity corrections. Dosimetric parameters evaluated include: mean GTV dose, GTV dose heterogeneities (peak-to-valley dose ratio, PVDR), skin dose and dose to other adjacent critical structures. Additionally, planning time and delivery efficiency was recorded. With 3D-MLC, dose escalation up to 23 Gy was simulated for all patient's plans. All 3D-MLC crossfire GRID plans exhibited excellent target coverage with mean GTV dose of 13.4 ± 0.5 Gy (range: 12.43-14.24 Gy) and mean PVDR of 2.0 ± 0.3 (range: 1.7-2.4). Maximal and dose to 5 cc of skin were 9.7 ± 2.7 Gy (range: 5.4-14.0 Gy) and 6.3 ± 1.8 Gy (range: 4.1-11.1 Gy), on average respectively. Three-dimensional-MLC treatment planning time was about an hour or less. Compared to traditional GRID-block, average beam on time was 20% less, while providing similar overall treatment time. With 3D-MLC plans, tumor dose can be escalated up to 23 Gy while respecting skin dose tolerances. The simple MLC-based 3D-crossfire GRID-therapy technique resulted in enhanced target coverage for de-bulking deep-seated bulky tumors, reduced skin toxicity and spare adjacent critical structures. This simple MLC-based approach can be easily adopted by any radiotherapy center. It provides detailed dosimetry and a safe and effective treatment by eliminating the heavy physical GRID-block and could potentially provide same day treatment. Prospective clinical trial with higher tumor-dose to bulky deep-seated tumors is anticipated.

收起

展开

DOI:

10.1002/acm2.12826

被引量:

11

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(207)

参考文献(25)

引证文献(11)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读