A treatment planning approach to spatially fractionated megavoltage grid therapy for bulky lung cancer.

来自 PUBMED

作者:

Costlow HNZhang HDas IJ

展开

摘要:

The purpose of this study was to explore the treatment planning methods of spatially fractionated megavoltage grid therapy for treating bulky lung tumors using multileaf collimator (MLC). A total of 5 patients with lung cancer who had gross tumor volumes ranging from 277 to 635 cm(3) were retrospectively chosen for this study. The tumors were from 6.5 to 9.6 cm at shortest dimension. Several techniques using either electronic compensation or intensity-modulated radiation therapy (IMRT) were used to create a variety of grid therapy plans on the Eclipse treatment planning system. The dose prescription point was calculated to the volume, and a dose of 20 Gy with 6-MV/15-MV beams was used in each plan. The dose-volume histogram (DVH) curves were obtained to evaluate dosimetric characteristics. In addition, DVH curves from a commercially available cerrobend grid collimator were also used for comparison. The linear-quadratic radiobiological response model was used to assess therapeutic ratios (TRs) and equivalent uniform doses (EUD) for all generated plans. A total of 6 different grid therapy plans were created for each patient. Overall, 4 plans had different electronic compensation techniques: Ecomps-Tubes, Ecomps-Circles, Ecomps-Squares, and Ecomps-Weave; the other 2 plans used IMRT and IMRT-Weave techniques. The DVH curves and TRs demonstrated that these MLC-based grid therapy plans can achieve dosimetric properties very similar to those of the cerrobend grid collimator. However, the MLC-based plans have larger EUDs than those with the cerrobend grid collimator. In addition, the field shaping can be performed for targets of any shape in MLC-based plans. Thus, they can deliver a more conformal dose to the targets and spare normal structures better than the cerrobend grid collimator can. The plans generated by the MLC technique demonstrated the advantage over the standard cerrobend grid collimator on accommodating targets and sparing normal structures. Overall, 6 different plans showed 6 different dosimetric parameters. However, an optimal grid therapy plan selection from among these 6 types requires more information from clinical trials and radiobiological studies.

收起

展开

DOI:

10.1016/j.meddos.2014.02.004

被引量:

8

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(133)

参考文献(0)

引证文献(8)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读