Development and clinical implementation of eclipse scripting-based automated patient-specific collision avoidance software.

来自 PUBMED

作者:

Mann TDPloquin NPGill WRThind KS

展开

摘要:

Increased use of Linac-based stereotactic radiosurgery (SRS), which requires highly noncoplanar gantry trajectories, necessitates the development of efficient and accurate methods of collision detection during the treatment planning process. This work outlines the development and clinical implementation of a patient-specific computed tomography (CT) contour-based solution that utilizes Eclipse Scripting to ensure maximum integration with clinical workflow. The collision detection application uses triangle mesh structures of the gantry and couch, in addition to the body contour of the patient taken during CT simulation, to virtually simulate patient treatments. Collision detection is performed using Binary Tree Hierarchy detection methods. Algorithm accuracy was first validated for simple cuboidal geometry using a calibration phantom and then extended to an anthropomorphic phantom simulation by comparing the measured minimum distance between structures to the predicted minimum distance for all allowable orientations. The collision space was tested at couch angles every 15° from 90 to 270 with the gantry incremented by 5° through the maximum trajectory. Receiver operating characteristic curve analysis was used to assess algorithm sensitivity and accuracy for predicting collision events. Following extensive validation, the application was implemented clinically for all SRS patients. The application was able to predict minimum distances between structures to within 3 cm. A safety margin of 1.5 cm was sufficient to achieve 100% sensitivity for all test cases. Accuracy obtained was 94.2% with the 5 cm clinical safety margin with 100% true positive collision detection. A total of 88 noncoplanar SRS patients have been currently tested using the application with one collision detected and no undetected collisions occurring. The average time for collision testing per patient was 2 min 58 s. A collision detection application utilizing patient CT contours was developed and successfully clinically implemented. This application allows collisions to be detected early during the planning process, avoiding patient delays and unnecessary resource utilization if detected during delivery.

收起

展开

DOI:

10.1002/acm2.12673

被引量:

9

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(122)

参考文献(9)

引证文献(9)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读