Determination of benzodiazepines in ante-mortem and post-mortem whole blood by solid-supported liquid-liquid extraction and UPLC-MS/MS.

来自 PUBMED

作者:

Sauve ENLangødegård MEkeberg DØiestad AM

展开

摘要:

A solid-supported liquid-liquid extraction ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of benzodiazepines commonly found in Norway, for use in cases with suspected driving impairment and autopsy cases by analysis of human whole blood samples. The following compounds were included: alprazolam, bromazepam, clonazepam, diazepam, flunitrazepam, lorazepam, midazolam, nitrazepam, nordiazepam (metabolite of diazepam), oxazepam and phenazepam. Aliquots of 500 μL whole blood were added 500 μL of borate buffer pH 11 and extracted by solid-supported liquid-liquid extraction on ChemElut(®) columns using three times 2.5 mL of methyl tert-butyl ether. Deuterated analogues were used as internal standards (IS) for all analytes, except for midazolam, phenazepam and bromazepam which had no commercially available deuterated analogues at the time the method was developed, and therefore used diazepam-d(5), flunitrazepam-d(7) and nitrazepam-d(5), respectively. The analytes were separated using UPLC with a 2.1×100 mm BEH C(18)-column, 1.7 μm particle size, and quantified by MS/MS using multiple reaction monitoring (MRM) in positive mode. Two transitions were used for the analytes and one transition for the IS. The run time of the method was 8 min including equilibration time. The concentrations of the benzodiazepines in the method span a broad range varying from the lowest concentration of 0.005 μM for flunitrazepam to the highest of 20 μM for oxazepam. The calibration curves of extracted whole blood standards were fitted by second-order calibration curves weighted 1/x, with R(2) values ranging from 0.9981 to 0.9998. The intermediate precision had a CV (%) ranging between 2 and 19%. Recoveries of the analytes were from 71 to 96%. The LLOQs for the analytes varied from 0.0006 to 0.075 μM and the LODs from 0.005 to 3.0 nM. Matrix effects were studied by post extraction addition and found to be between 95 and 104% when calculated against an internal standard. A comparison with two other LC-MS methods was performed during method validation. Good correlation was seen for all analytes. The method has been running on a routine basis for several years, and has proven to be very robust and reliable with good results for external quality samples. The method also meets the requirements of the legislative limits for driving under the influence of non-alcohol drugs to be introduced in the Norwegian legislative system from 2012.

收起

展开

DOI:

10.1016/j.jchromb.2011.10.033

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(1173)

参考文献(0)

引证文献(4)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读