Comparison of direct and indirect images and hemodynamic response of two different video laryngoscopes to tracheal intubation.
The aim of this study was to compare the effects of two different videolaryngoscopes (VLs) on direct (through the mouth) and indirect (screen images) laryngoscopy and to evaluate their effects on hemodynamic response.
A total of 70 patients between the ages of 18 and 65 years with ASA I-III physical status, planned for general anesthesia, with an expected difficult airway, were included in the study. Patients were enrolled in the study between 02/ 2022 and 06/ 2022. Patients were randomly divided into two groups. McGrath video laryngoscope was used in Group MC and Hugemed video laryngoscope was used in Group H. Modified Cormack Lehane and POGO scores (Percentage of glottic opening) of all patients on direct and indirect laryngoscopy were evaluated and recorded and then orotracheal intubation was performed. Demographic data, ASA status, Mallampati classification, thyromental distances and mouth opening were recorded. Standard monitoring was applied to all patients. During intubation, endotracheal intubation time, number of attempts, intubation-related complications and sore throat were recorded. Hemodynamic parameters (mean arterial pressure, peripheral oxygen saturation values) were recorded before, after induction and after intubation.
There was no difference between the groups in terms of descriptive characteristics (p > 0.05). When direct and indirect POGO scores were compared in group MC, no difference was found between the patients (p > 0.05). When direct and indirect POGO scores were compared, no difference was found between patients in Group H (p > 0.05). The mean POGO VL indirect score of Group H patients was found to be significantly higher than that of Group MC (p < 0.035) Both VLs showed similar results in terms of intubation time, number of attempts and hemodynamic findings.
McGrath and Hugemed videolaryngoscopes provide a good laryngeal view with similar Cormack Lehane scores during non-difficult endotracheal intubation and facilitate successful intubation by maintaining hemodynamic stability. It was observed that the Hugemed VL had a better indirect POGO score, but the images provided by the blades of both VLs on direct laryngoscopy allowed intubation.
NCT06649526. Clinical trials registration date 17/10/2024 ''retrospectively registered'".
Sezen Ö
,Şimşek T
,Şimşek AK
,Arslan G
,Saracoglu KT
,Saracoglu A
... -
《BMC Anesthesiology》
Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation.
Tracheal intubation is a common procedure performed to secure the airway in adults undergoing surgery or those who are critically ill. Intubation is sometimes associated with difficulties and complications that may result in patient harm. While it is traditionally achieved by performing direct laryngoscopy, the past three decades have seen the advent of rigid indirect videolaryngoscopes (VLs). A mounting body of evidence comparing the two approaches to tracheal intubation has been acquired over this period of time. This is an update of a Cochrane Review first published in 2016.
To assess whether use of different designs of VLs in adults requiring tracheal intubation reduces the failure rate compared with direct laryngoscopy, and assess the benefits and risks of these devices in selected population groups, users and settings.
We searched MEDLINE, Embase, CENTRAL and Web of Science on 27 February 2021. We also searched clinical trials databases, conference proceedings and conducted forward and backward citation searches.
We included randomized controlled trials (RCTs) and quasi-RCTs with adults undergoing laryngoscopy performed with either a VL or a Macintosh direct laryngoscope (DL) in any clinical setting. We included parallel and cross-over study designs.
We used standard methodological procedures expected by Cochrane. We collected data for the following outcomes: failed intubation, hypoxaemia, successful first attempt at tracheal intubation, oesophageal intubation, dental trauma, Cormack-Lehane grade, and time for tracheal intubation.
We included 222 studies (219 RCTs, three quasi-RCTs) with 26,149 participants undergoing tracheal intubation. Most studies recruited adults undergoing elective surgery requiring tracheal intubation. Twenty-one studies recruited participants with a known or predicted difficult airway, and an additional 25 studies simulated a difficult airway. Twenty-one studies were conducted outside the operating theatre environment; of these, six were in the prehospital setting, seven in the emergency department and eight in the intensive care unit. We report here the findings of the three main comparisons according to videolaryngoscopy device type. We downgraded the certainty of the outcomes for imprecision, study limitations (e.g. high or unclear risks of bias), inconsistency when we noted substantial levels of statistical heterogeneity and publication bias. Macintosh-style videolaryngoscopy versus direct laryngoscopy (61 studies, 9883 participants) We found moderate-certainty evidence that a Macintosh-style VL probably reduces rates of failed intubation (risk ratio (RR) 0.41, 95% confidence interval (CI) 0.26 to 0.65; 41 studies, 4615 participants) and hypoxaemia (RR 0.72, 95% CI 0.52 to 0.99; 16 studies, 2127 participants). These devices may also increase rates of success on the first intubation attempt (RR 1.05, 95% CI 1.02 to 1.09; 42 studies, 7311 participants; low-certainty evidence) and probably improve glottic view when assessed as Cormack-Lehane grade 3 and 4 (RR 0.38, 95% CI 0.29 to 0.48; 38 studies, 4368 participants; moderate-certainty evidence). We found little or no clear difference in rates of oesophageal intubation (RR 0.51, 95% CI 0.22 to 1.21; 14 studies, 2404 participants) but this finding was supported by low-certainty evidence. We were unsure of the findings for dental trauma because the certainty of this evidence was very low (RR 0.68, 95% CI 0.16 to 2.89; 18 studies, 2297 participants). We were not able to pool data for time required for tracheal intubation owing to considerable heterogeneity (I2 = 96%). Hyperangulated videolaryngoscopy versus direct laryngoscopy (96 studies, 11,438 participants) We found moderate-certainty evidence that hyperangulated VLs probably reduce rates of failed intubation (RR 0.51, 95% CI 0.34 to 0.76; 63 studies, 7146 participants) and oesophageal intubation (RR 0.39, 95% CI 0.18 to 0.81; 14 studies, 1968 participants). In subgroup analysis, we noted that hyperangulated VLs were more likely to reduce failed intubation when used on known or predicted difficult airways (RR 0.29, 95% CI 0.17 to 0.48; P = 0.03 for subgroup differences; 15 studies, 1520 participants). We also found that these devices may increase rates of success on the first intubation attempt (RR 1.03, 95% CI 1.00 to 1.05; 66 studies, 8086 participants; low-certainty evidence) and the glottic view is probably also improved (RR 0.15, 95% CI 0.10 to 0.24; 54 studies, 6058 participants; data for Cormack-Lehane grade 3/4 views; moderate-certainty evidence). However, we found low-certainty evidence of little or no clear difference in rates of hypoxaemia (RR 0.49, 95% CI 0.22 to 1.11; 15 studies, 1691 participants), and the findings for dental trauma were unclear because the certainty of this evidence was very low (RR 0.51, 95% CI 0.16 to 1.59; 30 studies, 3497 participants). We were not able to pool data for time required for tracheal intubation owing to considerable heterogeneity (I2 = 99%). Channelled videolaryngoscopy versus direct laryngoscopy (73 studies, 7165 participants) We found moderate-certainty evidence that channelled VLs probably reduce rates of failed intubation (RR 0.43, 95% CI 0.30 to 0.61; 53 studies, 5367 participants) and hypoxaemia (RR 0.25, 95% CI 0.12 to 0.50; 15 studies, 1966 participants). They may also increase rates of success on the first intubation attempt (RR 1.10, 95% CI 1.05 to 1.15; 47 studies, 5210 participants; very low-certainty evidence) and probably improve glottic view (RR 0.14, 95% CI 0.09 to 0.21; 40 studies, 3955 participants; data for Cormack-Lehane grade 3/4 views; moderate-certainty evidence). We found little or no clear difference in rates of oesophageal intubation (RR 0.54, 95% CI 0.17 to 1.75; 16 studies, 1756 participants) but this was supported by low-certainty evidence. We were unsure of the findings for dental trauma because the certainty of the evidence was very low (RR 0.52, 95% CI 0.13 to 2.12; 29 studies, 2375 participants). We were not able to pool data for time required for tracheal intubation owing to considerable heterogeneity (I2 = 98%).
VLs of all designs likely reduce rates of failed intubation and result in higher rates of successful intubation on the first attempt with improved glottic views. Macintosh-style and channelled VLs likely reduce rates of hypoxaemic events, while hyperangulated VLs probably reduce rates of oesophageal intubation. We conclude that videolaryngoscopy likely provides a safer risk profile compared to direct laryngoscopy for all adults undergoing tracheal intubation.
Hansel J
,Rogers AM
,Lewis SR
,Cook TM
,Smith AF
... -
《Cochrane Database of Systematic Reviews》
Hyperangulated versus Macintosh blades for intubation with videolaryngoscopy in ICU: the randomised multicentre INVIBLADE-ICU trial study protocol.
Compared with the operating room, tracheal intubations in the intensive care unit (ICU) are associated with worsened glottic view, decreased first-time success rate and increase in the technical difficulty of intubation and incidence of complications. Videolaryngoscopes (VLs) have been proposed to improve airway management, and while recent studies have confirmed that VLs improve intubation conditions in this patient population, there remains a lack of clarity regarding the selection between a standard Macintosh blade or a hyperangulated one, to determine which yields the best outcomes. The purpose of this study was to compare successful intubation on the first attempt with the Macintosh VL versus the hyperangulated VL during tracheal intubation in ICU patients. We hypothesise that tracheal intubation using the hyperangulated VL will improve the frequency of successful intubation on the first attempt.
The INtubation VIdeolaryngoscopy BLADE-ICU trial is a prospective, multicentre, open-label, interventional, randomised, controlled superiority study conducted in 29 ICUs in Spain. Patients will be randomly assigned in a 1:1 ratio to undergo intubation using a Macintosh VL (control group) or a hyperangulated VL (experimental group) for the first intubation attempt. The primary outcome is successful intubation on the first attempt. The secondary outcomes include the time to intubation, attempts for successful intubation, laryngoscopic vision assessed with the modified Cormack-Lehane scale, the need for adjuvant airway devices for intubation, difficulty assessed by the anaesthesiologist and complications during tracheal intubation. Enrolment began on 1 May 2024 and is expected to be completed in 2025.
The study protocol was approved on 29 February 2024, by the Ethics Committee of Galicia (CEImG, code No. 2024-031).The results will be submitted for publication in a peer-reviewed journal.
NCT06322719.
Taboada M
,Estany-Gestal A
,Fernández J
,Vazquez O
,Pajares A
,Ramasco F
,Martínez S
,Vallejo I
,Pérez A
,Rama-Maceiras P
,Bermúdez M
,Power M
,García-Álvarez R
,Fernández-Villa I
,Aguilera JL
,Carrió M
,Cabadas R
,Rubín A
,Williams MM
,Fernández-García R
,Becerra A
,Giné M
,García FJ
,Iglesias MC
,Santamarina RM
,Del Valle S
,Charco LM
,Alonso MC
,Rodríguez IM
,Varela M
,Hermoso JI
,Vives M
,Cabaleiro T
... -
《BMJ Open》