Disorientation as a delirium feature in non-intubated patients: development and evaluation of diagnostic accuracy of the 'Confusion Assessment Method for Intermediate Care Unit' (CAM-IMC) - a prospective cohort study.

来自 PUBMED

作者:

Beyer LPGathen LVZRayah BEDewald OZieschang TDiers AEly EWGuenther U

展开

摘要:

Disorientation is an early indicator of developing postoperative delirium (POD), which is associated with increased mortality and cognitive decline. The well-established "Confusion-Assessment-Method-for-Intensive-Care-Unit" (CAM-ICU) for diagnosing POD in intubated patients cannot make use of the feature 'disorientation', as this requires verbal communication. Other tools such as the 4AT test for disorientation but are not established in ICU settings. We therefore combined test-variables of the CAM-ICU (level of consciousness, fluctuating mental status and inattention) with verbal testing for disorientation to develop and enhance diagnostic accuracy of the "Confusion Assessment Method for Intermediate Care Unit" (CAM-IMC). In the present study we describe the development and the evaluation of the diagnostic accuracy of the CAM-IMC. We conducted a prospective cohort-study to develop and evaluate the diagnostic accuracy of the CAM-IMC and disorientation for diagnosing POD in non-intubated patients undergoing elective cardiac surgery. All patients were eligible during data collection period. Exclusion criteria were preexisting brain-organic disease, age < 50 years, preoperative intubation, and insufficient language skills. Patients were assessed for POD using the CAM-IMC as the index-test by two independent examiners over three postoperative days. Reference-testing was conducted by experienced reference-raters. The primary outcome was the diagnostic test-performance. Among 178 eligible patients, 624 paired observations were completed with 155 patients. Of these, 9% experienced POD. Sensitivity and specificity were 0.96 (CI-95%: 0.87-1.00) and 0.94 (CI-95%: 0.92-0.96), respectively. Area-Under-the-Receiver-Operating-Characteristic-Curve (AUROC; equivalent to c-statistic) for CAM-IMC with a cut-off at three points was 0.95 (CI-95%: 0.93-0.98). The interrater reliability was 0.80 (CI-95%: 0.69-0.91). The CAM-IMC demonstrates excellent test performance for diagnosing POD in non-intubated patients by combining features of the CAM-ICU with 'disorientation'. Given an aging community with an increasing delirium risk, the CAM-IMC provides a highly structured assessment tool for POD. It enables early and accurate detection of delirium, which is critical for timely intervention and improved patient outcomes. The CAM-IMC appears to be a useful tool to be implemented in units for not-intubated patients and seems to be the perfect match where the CAM-ICU is already in use for monitoring POD. DRKS00026980 (German registry of clinical studies).

收起

展开

DOI:

10.1186/s12871-024-02849-3

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(0)

引证文献(0)

来源期刊

BMC Anesthesiology

影响因子:2.374

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读