Diagnostic Performance of the Offline Medios Artificial Intelligence for Glaucoma Detection in a Rural Tele-Ophthalmology Setting.

来自 PUBMED

作者:

Upadhyaya SRao DPKavitha SBallae Ganeshrao SNegiloni KBhandary SSavoy FMVenkatesh R

展开

摘要:

This study assesses the diagnostic efficacy of offline Medios Artificial Intelligence (AI) glaucoma software in a primary eye care setting, using nonmydriatic fundus images from Remidio's Fundus-on-Phone (FOP NM-10). Artificial intelligence results were compared with tele-ophthalmologists' diagnoses and with a glaucoma specialist's assessment for those participants referred to a tertiary eye care hospital. Prospective cross-sectional study PARTICIPANTS: Three hundred three participants from 6 satellite vision centers of a tertiary eye hospital. At the vision center, participants underwent comprehensive eye evaluations, including clinical history, visual acuity measurement, slit lamp examination, intraocular pressure measurement, and fundus photography using the FOP NM-10 camera. Medios AI-Glaucoma software analyzed 42-degree disc-centric fundus images, categorizing them as normal, glaucoma, or suspect. Tele-ophthalmologists who were glaucoma fellows with a minimum of 3 years of ophthalmology and 1 year of glaucoma fellowship training, masked to artificial intelligence (AI) results, remotely diagnosed subjects based on the history and disc appearance. All participants labeled as disc suspects or glaucoma by AI or tele-ophthalmologists underwent further comprehensive glaucoma evaluation at the base hospital, including clinical examination, Humphrey visual field analysis, and OCT. Artificial intelligence and tele-ophthalmologist diagnoses were then compared with a glaucoma specialist's diagnosis. Sensitivity and specificity of Medios AI. Out of 303 participants, 299 with at least one eye of sufficient image quality were included in the study. The remaining 4 participants did not have sufficient image quality in both eyes. Medios AI identified 39 participants (13%) with referable glaucoma. The AI exhibited a sensitivity of 0.91 (95% confidence interval [CI]: 0.71-0.99) and specificity of 0.93 (95% CI: 0.89-0.96) in detecting referable glaucoma (definite perimetric glaucoma) when compared to tele-ophthalmologist. The agreement between AI and the glaucoma specialist was 80.3%, surpassing the 55.3% agreement between the tele-ophthalmologist and the glaucoma specialist amongst those participants who were referred to the base hospital. Both AI and the tele-ophthalmologist relied on fundus photos for diagnoses, whereas the glaucoma specialist's assessments at the base hospital were aided by additional tools such as Humphrey visual field analysis and OCT. Furthermore, AI had fewer false positive referrals (2 out of 10) compared to the tele-ophthalmologist (9 out of 10). Medios offline AI exhibited promising sensitivity and specificity in detecting referable glaucoma from remote vision centers in southern India when compared with teleophthalmologists. It also demonstrated better agreement with glaucoma specialist's diagnosis for referable glaucoma participants. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

收起

展开

DOI:

10.1016/j.ogla.2024.09.002

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读