Transperineal sonographic assessment of the angle of progression before the onset of labour: how well does it predict the mode of delivery in late-term pregnancy.
Predicting the success of vaginal delivery is an important issue in preventing adverse maternal and neonatal outcomes. This study sought to examine whether measurement of the angle of progression (AoP) can predict a successful vaginal delivery following induction of labour (IoL) among late term nulliparous women with a low (4>) Bishop score.
This prospective study included consecutive nulliparous pregnant women whose gestational age was 41 weeks and 1-6 days (late-term). The AoP was measured at least three times and their means were calculated.
During the study period, data of 150 women were included in the final analysis. Thirty-eight women underwent CS due to failure to progress (n=30) or NRGHR (n=8), while the remaining 112 women underwent NVD, with four women requiring vacuum extraction. The two groups were similar with respect to age, gestational age, BMI, estimated foetal weight, and birth weight. Women undergoing NVD differed significantly from those undergoing CS with respect to a greater ultrasonographic AoP (113.8±11.9° vs. 98.1±10.9°, p=0.0001), a shorter duration of dinoprostone use, shorter time to labour contraction, and a shorter duration of labour. In ROC analysis, the cut-off value for AoP was 100° for the prediction of successful IoL for NVD, with a sensitivity of 96 % and a specificity of 63 %.
AoP may be a useful sonographic parameter for predicting successful vaginal delivery among nulliparous women at late term undergoing IoL; an AOP wider than 100° is associated with a high rate of vaginal delivery.
Güner G
,Barut A
,Okcu NT
《-》
-
Transperineal sonographic assessment of angle of progression as a predictor of successful vaginal delivery following induction of labor.
To assess whether measurement of the angle of progression (AOP) before induction of labor (IOL) can predict successful vaginal delivery in nulliparous women.
This was a prospective, observational study of nulliparous women with a singleton term pregnancy and an indication for IOL. Transperineal sonography was used to measure the AOP before cervical ripening. Since all women enrolled had a low Bishop score, 98.6% of them were induced with either intracervical extra-amniotic balloon catheter or vaginal prostaglandin E-2. The staff in the labor ward were blinded to the AOP measurements. Clinical data were retrieved from computerized medical records.
Of the 150 women included in the final analysis, 40 (26.7%) delivered by Cesarean section. The median AOP was narrower in women who had a Cesarean delivery than in those who delivered vaginally (90° (interquartile range (IQR), 84-94.5°) vs 98° (IQR, 90.8-105°); P < 0.001). When including only women who underwent Cesarean delivery for non-progression of labor (n = 27) in the analysis, an AOP of > 92° (derived from a receiver-operating characteristics curve) was associated with a successful vaginal delivery in 94.8% of women. Multivariate stepwise logistic regression analysis including maternal age, body mass index, gestational age, estimated fetal weight, fetal head station, indication for IOL and AOP demonstrated that only AOP was independently associated with the prediction of a successful induction.
AOP may be a useful sonographic parameter for predicting successful vaginal delivery among nulliparous women at term undergoing IOL; an AOP wider than 92° is associated with a high rate of vaginal delivery. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Gillor M
,Vaisbuch E
,Zaks S
,Barak O
,Hagay Z
,Levy R
... -
《-》
-
Labor progress determined by ultrasound is different in women requiring cesarean delivery from those who experience a vaginal delivery following induction of labor.
The diagnosis of labor dystocia generally is determined by the deviation of labor progress, which is assessed by the use of a partogram. Recently, intrapartum transperineal ultrasound for the assessment of fetal head descent has been introduced to assess labor progress in the first stage of labor in a more objective and noninvasive way.
The objective of the study was to determine the differences in labor progress by the use of serial transperineal ultrasound assessment of fetal head descent between women having vaginal and cesarean delivery.
This was a prospective longitudinal study performed in 315 women with singleton pregnancy who were undergoing labor induction at term between December 2016 and December 2017. Paired assessment of cervical dilation and fetal head station by vaginal examination and transperineal ultrasonographic assessment of parasagittal angle of progression and head-perineum distance were made serially after the commencement of labor induction. According to the hospital protocol, assessment was performed every 24 hours and 4 hours, respectively, during latent and active phases of labor. The researchers and the clinical team were blinded to each other's findings. The repeated measures data were analyzed by mixed effect models. To determine the effect of mode of delivery on the association between parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation, the significance of the interaction term between each mode of delivery and fetal head station or cervical dilation was determined, which accounted for parity and obesity. Area under receiver-operating characteristic curve was used to evaluate the performance of serial intrapartum sonography in predicting women with cesarean delivery because of failure to progress.
The total number of paired vaginal examination and ultrasound assessments was 1198, with a median of 3 per woman. The median assessment-to-assessment interval was 4.6 hours (interquartile range, 4.3-5.1 hours). Women who achieved vaginal delivery (n=261) had steeper slopes of parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation than those who achieved cesarean delivery (n=54). Objectively, an additional decrease of 5.11 and 1.37 degrees in parasagittal angle of progression was observed for an unit increase in fetal head station and cervical dilation, respectively, in women who required cesarean delivery (P<.01; P=.01), compared with women who achieved vaginal delivery, after taking account of repeated measures from individuals and confounding factors. The respective additional increases in head-perineum distance for a unit increase in fetal head station and cervical dilation were 0.27 cm (P<.01) and 0.12 cm (P<.01). A combination of maternal characteristics with the temporal changes of parasagittal angle of progression for an unit increase in fetal head station achieved an area under receiver-operating characteristic curve of 0.85 (95% confidence interval, 0.76-0.94), with sensitivity of 79% and specificity of 80%, for the prediction of women who required cesarean delivery because of failure to progress.
The differences in labor progress between vaginal and cesarean delivery have been illustrated objectively by serial intrapartum transperineal ultrasonographic assessment of fetal head descent. This tool is potentially predictive of women who will require cesarean delivery because of failure to progress.
Tse WT
,Chaemsaithong P
,Chan WWY
,Kwan AHW
,Huang J
,Appiah K
,Chong KC
,Poon LC
... -
《-》
-
Prediction of spontaneous vaginal delivery in nulliparous women with a prolonged second stage of labor: the value of intrapartum ultrasound.
A limited number of studies have addressed the role of intrapartum ultrasound in the prediction of the mode of delivery in women with prolonged second stage of labor.
The objective of the study was to evaluate the role of transabdominal and transperineal sonographic findings in the prediction of spontaneous vaginal delivery among nulliparous women with prolonged second stage of labor.
This was a 2-center prospective study conducted at 2 tertiary maternity units. Nulliparous women with a prolonged active second stage of labor, as defined by active pushing lasting more than 120 minutes, were eligible for inclusion. Transabdominal ultrasound to evaluate the fetal head position and transperineal ultrasound for the measurement of the midline angle, the head-perineum distance, and the head-symphysis distance were performed in between uterine contractions and maternal pushes. At transperineal ultrasound the angle of progression was measured at rest and at the peak of maternal pushing effort. The delta angle of progression was defined as the difference between the angle of progression measured during active pushing at the peak of maternal effort and the angle of progression at rest. The sonographic findings of women who had spontaneous vaginal delivery vs those who required obstetric intervention, either vacuum extraction or cesarean delivery, were evaluated and compared.
Overall, 109 were women included. Spontaneous vaginal delivery and obstetric intervention were recorded in 40 (36.7%) and 69 (63.3%) patients, respectively. Spontaneous vaginal delivery was associated with a higher rate of occiput anterior position (90% vs 53.2%, P < .0001), lower head-perineum distance and head-symphysis distance (33.2 ± 7.8 mm vs 40.1 ± 9.5 mm, P = .001, and 13.1 ± 4.6 mm vs 19.5 ± 8.4 mm, P < .001, respectively), narrower midline angle (29.6° ± 15.3° vs 54.2° ± 23.6°, P < .001) and wider angle of progression at the acme of the pushing effort (153.3° ± 19.8° vs 141.8° ± 25.7°, P = .02) and delta-angle of progression (17.3° ± 12.9° vs 12.5° ± 11.0°, P = .04). At logistic regression analysis, only the midline angle and the head-symphysis distance proved to be independent predictors of spontaneous vaginal delivery. More specifically, the area under the curve for the prediction of spontaneous vaginal delivery was 0.80, 95% confidence interval (0.69-0.92), P < .001, and 0.74, 95% confidence interval (0.65-0.83), P = .002, for the midline angle and for the head-symphysis distance, respectively.
Transabdominal and transperineal intrapartum ultrasound parameters can predict the likelihood of spontaneous vaginal delivery in nulliparous women with prolonged second stage of labor.
Dall'Asta A
,Angeli L
,Masturzo B
,Volpe N
,Schera GBL
,Di Pasquo E
,Girlando F
,Attini R
,Menato G
,Frusca T
,Ghi T
... -
《-》
-
Sonographic prediction of vaginal delivery in prolonged labor: a two-center study.
To investigate whether head-perineum distance (HPD) measured by transperineal ultrasound is predictive of vaginal delivery and time remaining in labor in nulliparous women with prolonged first stage of labor and to compare the predictive value with that of angle of progression (AoP).
This was a prospective observational study at Stavanger University Hospital, Norway and Addenbrooke's Hospital, Cambridge, UK from January 2012 to April 2013, of nulliparous women with singleton pregnancies with cephalic presentation at term with prolonged first stage of labor. We used transperineal ultrasound to measure HPD (shortest distance between the outer bony limit of the fetal skull and the perineum) and AoP (angle between a line through the long axis of the symphysis and the tangent to the fetal head) and transabdominal ultrasound to classify fetal head position. The main outcomes were vaginal delivery and time remaining in labor.
Of 150 women enrolled, 39 underwent delivery by Cesarean section. The area under the receiver-operating characteristics curve for the prediction of vaginal delivery was 81% (95% CI, 73-89%) using HPD as the test variable and 72% (95% CI, 63-82%) using AoP. HPD was ≤ 40 mm in 84 (56%) women, of whom 77 (92%; 95% CI, 84-96%) delivered vaginally. HPD was > 40 mm in the other 66 (44%) women, of whom 34 (52%; 95% CI, 40-63%) delivered vaginally. AoP was ≥ 110° in 84 of the 145 (58%) in whom this was available and, of these, 74 (88%; 95% CI, 79-93%) delivered vaginally. AoP was < 110° in the other 61 (42%) women, of whom 35 (57%; 95% CI, 45-69%) delivered vaginally. Multivariable logistic regression analysis showed that HPD ≤ 40 mm (odds ratio (OR), 4.92; 95% CI, 1.54-15.80), AoP ≥ 110° (OR, 3.11; 95% CI, 1.01-9.56), non-occiput posterior position (OR, 3.36; 95% CI, 1.24-9.12) and spontaneous onset of labor (OR, 4.44; 95% CI, 1.42-13.89) were independent predictors for vaginal delivery. Both ultrasound methods were predictive for the time remaining in labor.
Transperineal ultrasound measurement of HPD and AoP provide important information about the likelihood of vaginal delivery and the time remaining in labor in nulliparous women with prolonged labor.
Eggebø TM
,Hassan WA
,Salvesen KÅ
,Lindtjørn E
,Lees CC
... -
《-》