Early-stage Development of the CoRISMA Mechanical Circulatory Support (CMCS) System for Heart Failure Therapy.

来自 PUBMED

作者:

Monreal GKoenig SCKelley JFIllg JJTamez DKelley MSYetukuri VCross DPTheran MESlaughter MS

展开

摘要:

CoRISMA MCS Systems Inc (Hamden CT) is developing an innovative mechanical circulatory support system (CMCS) as a durable therapeutic option for heart failure (HF) patients. The CMCS system is comprised of an axial flow pump, non-contacting hydrodynamic bearings, and integrated DC motor designed to be fully implantable in a left atrial (LA) to aortic (Ao) configuration; this unloading strategy may be particularly beneficial for HF patients with preserved ejection fraction (HFpEF). The small (5.5 cm3), lightweight (20 g), and low power (5-7 W) device design should allow for a less invasive off-pump implant. We present early-stage engineering development and testing of the prototype CoRISMA pumps. Computational fluid dynamics (CFD) modeling was performed to evaluate flow and shear in two impeller (3 blades, 0.5 mm thickness, 8.9 mm diameter, 0.15 mm gap, polished titanium) and diffusor (5 blades, polished titanium) candidate designs. Test apparatuses were custom built to expedite development of the impeller/diffuser designs and iteratively refine the CFD models. Two candidate impeller/diffusor designs were fabricated and tested in each of the two test apparatuses (n = 4 impeller/diffuser + test fixture configurations) in static mock flow loops (hydrodynamic H-Q curves, 3.5 cP glycerol solution at 37 °C), and in dynamic mock flow loops (hemodynamics, 3.5 cP glycerol solution at 37 °C) tuned to HF conditions (mean aortic pressure 50 mmHg, central venous pressure 15 mmHg, aortic flow 3.0 L/min, and heart rate 80 bpm). CFD predicted flows of 4.56 L/min and 4.82 L/min at 100 mmHg for impellers/diffusers 1 and 2, respectively. Impeller 2 required less torque to generate a 6% increase in fluidic flow, and the diffuser had a larger area of high pressure, indicative of lower friction, which likely contributed to the increased efficiency. Experimental testing for all four configurations in the static and dynamic mock loops met performance metrics as evidenced by generating 4.0-4.5 L/min flow against 70-76 mmHg pressure at 25,000 rpm and restoring hemodynamics in the dynamic mock flow loop (MAP = 80 mmHg, CVP = 0 mmHg, total flow = 5.5 L/min) from baseline simulated HF test conditions. These results demonstrate proof-of-concept of the early engineering design and performance of the prototype CoRISMA pumps. Engineering specifications, challenges observed, and proposed solutions for the next design iteration were identified for the continued development of an effective, reliable, and safe LA-to-Ao CMCS system for HF patients. Current design plans are underway for incorporating a wireless energy transfer system for communication and power, eliminating the need for and complications associated with an external driveline, to achieve a fully-implantable system.

收起

展开

DOI:

10.1007/s13239-024-00743-0

被引量:

1

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(22)

引证文献(1)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读