Minimizing normal tissue low dose bath for left breast Volumetric Modulated Arc Therapy (VMAT) using jaw offset.

来自 PUBMED

作者:

Zhang YFu WBrandner EPercinsky SMoran MHuq MS

展开

摘要:

With proper beam setup and optimization constraints in the treatment planning system, volumetric modulated arc therapy (VMAT) can improve target dose coverage and conformity while reducing doses to adjacent structures for whole breast radiation therapy. However, the low-dose bath effect on critical structures, especially the heart and the ipsilateral lung, remains a concern. In this study, we present a VMAT technique with the jaw offset VMAT (JO-VMAT) to reduce the leakage and scatter doses to critical structures for whole breast radiation therapy. The data of 10 left breast cancer patients were retrospectively used for this study. CT images were acquired on a CT scanner (GE, Discovery) with the deep-inspiration breath hold (DIBH) technique. The planning target volumes (PTVs) and the normal structures (the lungs, the heart, and the contralateral breast) were contoured on the DIBH scan. A 3D field-in-field plan (3D-FiF), a tangential VMAT (tVMAT) plan, and a JO-VMAT plan were created with the Eclipse treatment planning system. An arc treatment field with the x-jaw closed across the central axis creates a donut-shaped high-dose distribution and a cylinder-shaped low-dose volume along the central axis of gantry rotation. Applying this setup with proper multi-leaf collimator (MLC) modulation, the optimized plan potentially can provide sufficient target coverage and reduce unnecessary irradiation to critical structures. The JO-VMAT plans involve 5-6 tangential arcs (3 clockwise arcs and 2-3 counterclockwise arcs) with jaw offsets. The plans were optimized with objective functions specified to achieve PTV dose coverage and homogeneity; For organs at risk (OARs), objective functions were specified individually for each patient to accomplish the best achievable treatment plan. For tVMAT plans, optimization constraints were kept the same except that the jaw offset was removed from the initial beam setup. The dose volume histogram (DVH) parameters were generated for dosimetric evaluation of PTV and OARs. The D95% to the PTV was greater than the prescription dose of 42.56 Gy for all the plans. With both VMAT techniques, the PTV conformity index (CI) was statistically improved from 0.62 (3D-FiF) to 0.83 for tVMAT and 0.84 for JO-VMAT plans. The difference in the homogeneity index (HI) was not significant. The Dmax to the heart was reduced from 12.15 Gy for 3D-FiF to 8.26 Gy for tVMAT and 7.20 Gy for JO-VMAT plans. However, a low-dose bath effect was observed with tVMAT plans to all the critical structures including the lungs, the heart, and the contralateral breast. With JO-VMAT, the V5Gy and V2Gy of the heart were reduced by 32.7% and 15.4% compared to 3D-FiF plans. Significantly, the ipsilateral lung showed a reduction in mean dose (4.65-3.44 Gy) and low dose parameters (23.4% reduction for V5Gy and 10.7% reduction for V2Gy) for JO-VMAT plans compared to the 3D-FiF plans. The V2Gy dose to the contralateral lung and breast was minimal with JO-VMAT techniques. A JO-VMAT technique was evaluated in this study and compared with 3D-FiF and tVMAT techniques. Our results showed that the JO-VMAT technique can achieve clinically comparable coverage and homogeneity and significantly improve dose conformity within PTV. Additionally, JO-VMAT eliminated the low-dose bath effect at all OARs evaluation metrics including the ipsilateral/contralateral lung, the heart, and the contralateral breast compared to 3D-FiF and tVMAT. This technique is feasible for the whole breast radiation therapy of left breast cancers.

收起

展开

DOI:

10.1002/acm2.14365

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(269)

参考文献(34)

引证文献(0)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读