Comparison of bioelectrical impedance analysis and computed tomography for the assessment of muscle mass in patients with gastric cancer.

来自 PUBMED

作者:

Zuo JZhou DZhang LZhou XGao XHou WWang CJiang PWang X

展开

摘要:

Low muscle mass was significantly correlated with poor clinical outcomes in cancer patients. This study aimed to compare the differences between bioelectrical impedance analysis (BIA) and computed tomography (CT) in measuring skeletal muscle mass and detecting low muscle mass in patients with gastric cancer (GC). This cross-sectional study included a total of 302 consecutive patients diagnosed with GC at our institution from October 2021 to March 2023. CT images were analyzed at the L3 level to obtain the cross-sectional area of skeletal muscle, which was subsequently used for calculating whole-body skeletal muscle mass via the Shen equation and skeletal muscle tissue density. BIA was utilized to measure skeletal muscle mass using the manufacturer's proprietary algorithms. Skeletal muscle mass (kg) was divided by height squared (m2) to obtain skeletal muscle index (SMI, kg/m2). Pearson's correlation coefficient was performed to assess the correlation between SMI measured by BIA and CT. The agreement between the two methods was assessed using Bland-Altman analyses. The clinically acceptable agreement was defined as the 95% limits of agreement (LOA) for the percentage bias falling within ± 10%. The area under the receiver operating characteristic curve (AUC) was used to evaluate the performance of BIA in identifying low muscle mass. A total of 59 patients (19.5%) were identified as having low muscle mass based on CT analysis, whereas only 19 patients (6.3%) met the criteria for low muscle mass according to BIA analysis. BIA-measured SMI showed a strong positive correlation with CT-measured SMI in all patients (r = 0.715, P < 0.001). With Bland-Altman analysis, there was a significant mean bias of 1.18 ± 0.96 kg/m2 (95% CI 1.07-1.29, P < 0.001) between SMI measured by BIA and CT. The 95% LOA for the percentage bias ranged from -7.98 to 33.92%, which exceeded the clinically acceptable range of ± 10%. A significant difference was observed in the mean bias of SMI measured by BIA and CT between patients with and without GLIM malnutrition (1.42 ± 0.91 kg/m2 versus 0.98 ± 0.96 kg/m2, P < 0.001). The cut-off values for BIA-measured SMI in identifying low muscle mass using CT as the reference were 10.11 kg/m2 for males and 8.71 kg/m2 for females (male: AUC = 0.840, 95% CI: 0.772-0.908; female: AUC = 0.721, 95% CI: 0.598-0.843). Despite a significant correlation, the values of skeletal muscle mass obtained BIA and CT cannot be used interchangeably. The BIA method may overestimate skeletal muscle mass in GC patients compared to CT, especially among those with GLIM malnutrition, leading to an underestimation of low muscle mass prevalence.

收起

展开

DOI:

10.1016/j.nut.2024.112363

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(196)

参考文献(0)

引证文献(2)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读