On-site CT-derived cFFR in patients with suspected coronary artery disease: Feasibility on a 128-row CT scanner in everyday clinical practice.

来自 PUBMED

作者:

Baumeister TKloth CSchmidt SAKloempken SBrunner HBuckert DBernhardt PPanknin CBeer M

展开

摘要:

Technical feasibility of CT-based calculation of fractional flow reserve (cFFR) using a 128-row computed tomography scanner in an everyday routine setting. Post-processing and everyday practicability should be analyzed on the scanner on-site in connection with clinical parameters. This single-center retrospective analysis included 230 patients (74 female; mean age 63.8 years) with CCTA within 21 months between 01/2018 and 09/2019 without non-pathological examinations. cFFR values were obtained using a deep learning-based non-commercial research prototype (cFFR Version3.5.0; Siemens Healthineers GmbH, Erlangen). cFFR values were evaluated at two points: at the maximum point of the stenosis and 1.0 cm distal to the stenosis. Comparison with invasive coronary angiography in 57/230 patients (24.7 %) was performed. CT parameters and quality were evaluated. Further subgroup classification concerning criteria of technical postprocessing was performed: no changes necessary, minor corrections necessary, major corrections necessary, and no evaluation was possible. The required time from starting the software to the final result was evaluated. A total of 116/448 (25.9 %) mild, 223/448 (49.8 %) moderate, and 109/448 (24.3 %) obstructive stenoses was found. The mean cFFR at the maximum point of the stenosis was 0.92 ± 0.09 and significantly higher than the cFRR value of 0.89 ± 0.13 distal to the stenosis (p < 0.001*). The mean degree of stenosis was 44.02 ± 26.99 % (range: 1-99 %) with an area of 5.39 ± 3.30 mm2. In a total of 45 patients (19.1 %), a relevant reduction in cFFR below 0.80 was determined. Overall, in 57/230 patients (24.8 %), catheter angiography was performed. No significant difference in the degree of maximal stenosis (CAD-RADS 0-2/3/4) was detected between the classification of CCTA and ICA (p = 0.171). The mean post-processing time varied significantly with 8.34 ± 4.66 min. in single-vessel CAD vs. 12.91 ± 3.92 min. in two-vessel CAD vs. 21.80 ± 5.94 min. in three-vessel CAD (each p < 0.001). Noninvasive onsite quantification of cFFR is feasible with minimal observer interaction in a routine real-world setting on a 128-row scanner. Deep learning-based algorithms allow a robust and semi-automatic on-site determination of cFFR based on data from standard CT scanners. · Non-invasive on-site quantification of cFFR is feasible with minimal observer interaction.. · Deep-learning based algorithms allow robust and semi-automatic on-site determination of cFFR.. · The mean follow-up time varied significantly with the extent of vascular CAD..

收起

展开

DOI:

10.1055/a-2142-1643

被引量:

1

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(0)

引证文献(1)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读