An approach to difficult airway in infants: Comparison of GlideScope® Spectrum LoPro, GlideScope® Spectrum Miller and conventional Macintosh and Miller blades in a simulated Pierre Robin sequence performed by 90 anesthesiologists.
摘要:
Airway management can be challenging in neonates and infants. The Pierre Robin sequence (PRS) is a condition characterized by micrognathia, glossoptosis and airway obstruction. The airway management of these patients poses great challenges for anesthesiologists and pediatricians alike. To date, there has been no direct comparison of the hyperangulated GlideScope® Spectrum LoPro (GLP), the straight GlideScope® Spectrum Miller (GSM), a conventional Macintosh (MC) and a conventional Miller blade (ML) in patients with PRS. For this purpose, 90 anesthesiologists (43 with limited experience, 47 with extensive experience) performed orotracheal intubation on an Air-Sim® Pierre Robin X manikin using GLP, GSM, MC and ML in randomized order. 'Time-to-vocal-cords', 'time-to-intubate', 'time-to-ventilate', the severity of oral-soft-tissue-trauma and the subjective evaluation of each device were recorded. A significantly faster and better view of the vocal cords and lower oral-soft-tissue-trauma was achieved using the GLP (p<0.001). Though, there were no significant differences in the 'time-to-intubate' or 'time-to-ventilate'. The highest intubation success rate was found with GSM and the lowest with GLP (GSM 100%, ML 97.8%, MC 96.7%, GLP 93.3%). When using the videolaryngoscopes, there were no undetected esophageal intubations but in six cases prolonged attempts of intubation (>120s) with the GLP. In the sub-group with extensive experience, we found significantly shorter intubation times for the GSM and ML. The GLP was the tool of choice for most participants, while the conventional MC received the lowest rating. Videolaryngoscopy leads to increased safety for the prevention of undetected esophageal intubation in the airway management in a PRS manikin. Hyperangulated blades may ensure a good and fast view of the vocal cords and low oral-soft-tissue-trauma but pose a challenge during the placement of the tube. Specific skills and handling seem to be necessary to ensure a safe tube placement with this sort of blades.
收起
展开
DOI:
10.1371/journal.pone.0288816
被引量:
年份:
1970


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(101)
参考文献(29)
引证文献(3)
来源期刊
影响因子:3.748
JCR分区: 暂无
中科院分区:暂无