A formalism for traceable dosimetry in superficial electronic brachytherapy (eBT).

来自 PUBMED

作者:

de Prez LAvilés Lucas PKok E

展开

摘要:

Objective. Despite the number of treatments performed with electronic brachytherapy (eBT) there is no uniform methodology for reference dosimetry for international traceability to primary dosimetry standards in different eBT systems. The objective of this study is to propose a formalism for traceability reference dosimetry in superficial eBT, that is easy to apply in the clinic. This method was investigated for an Elekta Esteya with one applicator.Approach. The calibration x-ray spectrum at the primary standards dosimetry laboratory was matched to the measured eBT photon spectrum. Subsequently, two ionization chambers of different types were calibrated at the primary standard dosimetry laboratory (PSDL) in terms of air kerma against a primary standard. The chambers were used to measure ionization chamber reading ratios in-air at different distances from the applicator. Monte Carlo based air kerma ratios were calculated at different positions from the eBT applicator as well as backscatter factors in water and average mass energy absorption ratios in water and in air. Relative measurements with radiochromic films were performed in a water phantom to determine the ratio of absorbed dose to water,Dw, at the surface toDwat 1 cm depth in water. These were compared with Monte Carlo calculations.Main results. Calculations and measurements were combined to estimate theDwat the surface and at 1 cm depth in water. Ionization chamber agreement of the surface dose was 1.7%, within an uncertainty of 6.8% (k= 2). They agreed with the manufacturer dosimetry within 1.8%, with an uncertainty of 5.0% (k= 2). The feasibility of the formalism and methodology for the Esteya system was demonstrated.Significance. This study proposes a method for harmonization of traceable reference dosimetry for eBT contact treatments which does not involve a detailed simulation of the ionization chamber. The method demonstrated feasibility for one eBT system using one surface applicator. In the future the method could be applied for different eBT systems.

收起

展开

DOI:

10.1088/1361-6560/ace7a9

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(117)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读