Loss of His-bundle and Right Ventricular Septal Capture Following Transcatheter Aortic Valve Replacement-A Case Report.

来自 PUBMED

作者:

Asreb AAhn J

展开

摘要:

Conduction abnormalities following transcatheter aortic valve replacement (TAVR) are common. High-grade atrioventricular block (AVB) and new-onset left bundle branch block remain the most reported. These often require the placement of a permanent pacemaker (PPM). His-bundle (HB) pacing is increasingly being utilized as the preferred mode of ventricular pacing due to its more physiologic ventricular activation. In this case report, we present a case of a patient who developed loss of HB capture and experienced an increase in the local right ventricular (RV) capture threshold after TAVR that led to unrecognized intermittent loss of ventricular capture and symptoms. An 80-year-old man with severe aortic stenosis presented with symptomatic bradycardia due to typical atrial flutter (AFL) with a high-grade AVB and an underlying right bundle branch block. He underwent placement of a dual-chamber PPM (Medtronic, Inc., Minneapolis, MN, USA) with a HB pacing lead. HB mapping demonstrated a normal H-V interval, and the lead was fixated with non-selective HB capture. The R-waves measured 2.8 mV, the pacing impedance was 544 Ω, and the non-selective HB and local RV capture threshold was 0.5 V @ 1 ms. He underwent AFL ablation, and his atrial leads were normal. He subsequently underwent successful TAVR with a 29-mm Sapien 3 valve (Edwards Lifesciences, Irvine, CA, USA). Post-TAVR, PPM interrogation showed a loss of HB capture with a left bundle paced QRS morphology. Following discharge, he presented with stroke-like symptoms and was noted to have intermittent loss of RV capture with complete heart block (CHB) and a slow ventricular escape rhythm. PPM interrogation revealed an elevated pacing threshold, and his RV output was gradually increased to a maximum output of 7.5 V @ 1.5 ms. He also developed a fever and was found to have enterococcal bacteremia. Transesophageal echocardiography demonstrated vegetations on his prosthetic valve and pacemaker lead, without a perivalvular abscess. He underwent explantation of the pacemaker system and insertion of a temporary PPM. After intravenous antibiotic therapy with negative blood cultures, he underwent re-implantation of a new right-sided dual-chamber PPM, and an RV pacing lead was placed into the RV outflow tract. HB pacing is becoming the preferred mode of physiologic ventricular pacing. This case illustrates the potential risks of the TAVR procedure in patients with existing HB pacing leads. We observed a loss of HB capture and the development of CHB due to traumatic injury to the HB distal to the HB pacing lead after TAVR placement together with an increase in the local RV capture threshold. The depth of TAVR placement is an important aspect of the TAVR procedure that determines the risk of developing CHB and may also affect the HB and local RV pacing thresholds post-procedure.

收起

展开

DOI:

10.19102/icrm.2023.14022

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(290)

参考文献(11)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读