-
Head-to-head comparison of [(68)Ga]Ga-P16-093 and 2-[(18)F]FDG PET/CT in patients with clear cell renal cell carcinoma: a pilot study.
This pilot study was prospectively designed to evaluate and compare the diagnostic value of PET/CT using a PSMA-specific tracer [68Ga]Ga-P16-093 and a glucose metabolism probe 2-[18F]FDG in clear cell renal cell carcinoma (ccRCC) patients.
Forty-two pathologically confirmed ccRCC patients were included. Within 1 week, each patient underwent [68Ga]Ga-P16-093 and 2-[18F]FDG PET/CT. In addition to visual analysis of tumor number, the standardized uptake value (SUV) was measured for semiquantitative comparison and correlation analysis.
For primary ccRCC patients, [68Ga]Ga-P16-093 PET/CT demonstrated a significantly higher detection rate (19/22 vs. 13/22, P = 0.031) and higher tumor uptake (15.7 ± 9.0 vs. 5.1 ± 3.4, P < 0.001) than 2-[18F]FDG PET/CT. In addition, the SUVmax of the primary tumor on [68Ga]Ga-P16-093 and 2-[18F]FDG PET/CT was significantly correlated with pT stage (for [68Ga]Ga-P16-093, r = 0.550, P = 0.008; for 2-[18F]FDG, r = 0.514, P = 0.014) and WHO/ISUP grade (for [68Ga]Ga-P16-093, r = 0.566, P = 0.006; for 2-[18F]FDG, r = 0.492, P = 0.020), respectively. For metastatic ccRCC patients, [68Ga]Ga-P16-093 PET/CT also demonstrated a better detection rate (21/22 vs. 14/22, P = 0.008) and higher tumor uptake (11.0 ± 6.4 vs. 4.4 ± 2.7, P < 0.001) than 2-[18F]FDG PET/CT. The SUVmax on [68Ga]Ga-P16-093 PET/CT had a significant association with PSMA expression in primary ccRCC (r = 0.776, P < 0.001) and metastatic ccRCC (r = 0.626, P = 0.029).
[68Ga]Ga-P16-093 PET/CT demonstrates significantly better tumor detectability than 2-[18F]FDG PET/CT for ccRCC patients.
68Ga-P16-093 and 18F-FDG PET/CT Imaging in the Same Group of Clear Cell Renal Cell Carcinoma Patients (NCT05432947, Registered 27 June 2021, retrospectively registered) URL OF REGISTRY: https://clinicaltrials.gov/ct2/show/NCT05432947 .
Wang G
,Li L
,Wang J
,Zang J
,Chen J
,Xiao Y
,Fan X
,Zhu L
,Kung HF
,Zhu Z
... -
《-》
-
[(68)Ga]Ga‑LNC1007 PET/CT in the evaluation of renal cell carcinoma: comparison with 2-[(18)F]FDG/[(68)Ga]Ga-PSMA PET/CT.
To compare the potential efficiency of [68Ga]Ga-LNC1007 with 2-[18F]FDG/[68Ga]Ga-PSMA PET/CT for detecting renal cell carcinoma (RCC) and to explore parameters derived from [68Ga]Ga-LNC1007 PET/CT for discriminating pathological characteristics in RCC.
Twenty-five RCC patients confirmed by pathology were enrolled in this prospective study. The maximum standardized uptake value (SUVmax), mean SUV (SUVmean), gross tumor volume (GTV) and total lesion-tracer (TL-tracer) of lesions were calculated from the corresponding PET/CT images. Pathological characteristics included World Health Organization/International Society of Urological Pathology (WHO/ISUP) grade and adverse pathological features (tumor necrosis or sarcomatoid or rhabdoid feature).
[68Ga]Ga-LNC1007 PET/CT showed a higher detection rate for primary lesions than 2-[18F]FDG and [68Ga]Ga-PSMA (LNC1007 vs. FDG: 13/17 vs. 4/17, P = 0.005; LNC1007 vs. PSMA: 9/11 vs. 6/11, P = 0.361). [68Ga]Ga-LNC1007 PET/CT showed higher SUVmax (6.6 vs. 3.7, P = 0.005), SUVmean (4.1 vs. 2.3, P = 0.001) and TBR (2.6 vs. 1.7, P = 0.011) compared with 2-[18F]FDG PET/CT, and it also showed higher TBR (2.9 vs. 0.5, P = 0.003), TBR-delay (2.8 vs. 0.3, P = 0.003), GTV (84.1 vs. 42.9, P = 0.003) and TL-tracer (442.7 vs. 235.8, P = 0.008) compared with [68Ga]Ga-PSMA PET/CT. SUVmax and TBR derived from [68Ga]Ga-LNC1007 PET/CT could effectively differentiate WHO/ISUP grade (3-4 vs. 1-2) and adverse pathological features (positive vs. negative) (SUVmax: AUC 0.81, P = 0.04; AUC 0.80, P = 0.033; TBR: AUC 0.84, P = 0.026; AUC 0.85, P = 0.014). The SUVmax was positively correlated with the FAP expression, integrin αvβ3 expression and the total expression of FAP and integrin αvβ3 (r = 0.577, P = 0.006, r = 0.701, P < 0.001, and r = 0.702, P < 0.001, respectively).
[68Ga]Ga-LNC1007 is a promising tracer for RCC imaging and can effectively identify aggressive pathological characteristics of RCC.
Lin R
,Wang C
,Chen S
,Lin T
,Cai H
,Chen S
,Yang Y
,Zhang J
,Xu F
,Zhang J
,Chen X
,Zang J
,Miao W
... -
《-》
-
Head-to-head comparisons of enhanced CT, 68Ga-PSMA-11 PET/CT and 18F-FDG PET/CT in identifying adverse pathology of clear-cell renal cell carcinoma: a prospective study.
Accurate preoperative prediction of adverse pathology is crucial for treatment planning of renal cell carcinoma (RCC). Previous studies have emphasized the potential of prostate-specific membrane antigen positron emission tomography / computed tomography (PSMA PET/CT) in differentiating between benign and malignant localized renal tumors. However, there is a scarcity of case reports elucidating the identification of aggressive pathological features using PET/CT. Our study was designed to prospectively compare the diagnostic value of enhanced CT, 68Ga-PSMA-11 and 18F-fluorodeoxyglucose (18F-FDG) PET/CT in clear-cell renal cell carcinoma (ccRCC) with necrosis or sarcomatoid or rhabdoid differentiation.
A prospective case series of patients with a newly diagnosed renal mass who underwent enhanced CT, 68Ga-PSMA-11 and 18F-FDG PET/CT within 30 days prior to nephrectomy was included. Complete preoperative and postoperative clinicopathological data were recorded. Patients who received neoadjuvant targeted therapy, declined enhanced CT or PET/CT scanning, refused surgical treatment or had non-ccRCC pathological indications were excluded. Radiological parameters were compared within subgroups of pathological characteristics. Bonferroni corrections were used to adjust for multiple testing and statistical significance was set at a p-value less than 0.017.
Seventy-two patients were available for the final analysis. Enhanced CT demonstrated poor performance in identifying necrosis, sarcomatoid or rhabdoid differentiation and adverse pathology (all P > 0.05). The maximum standardized uptake value (SUVmax) of 68Ga-PSMA-11 PET/CT was more effective than 18F-FDG PET/CT in identifying tumor necrosis and adverse pathology, with an area under the curve (AUC) of 0.85 (cutoff value=25.26, p<0.001; Delong test z=2.709, p=0.007) for tumor necrosis and AUC of 0.90 (cutoff value=25.26, p<0.001; Delong test z=3.433, p<0.001) for adverse pathology. However, no significant statistical difference was found between 68Ga-PSMA-11 and 18F-FDG PET/CT in predicting sarcomatoid or rhabdoid feature (AUC of 0.91 vs.0.75, Delong test z=1.998, p=0.046). Subgroup analyses based on age, sex, tumor location, maximal diameter, stage and WHO/ISUP grade demonstrated that 68Ga-PSMA-11 PET/CT SUVmax had a significant predictive value for adverse pathology. Enhanced CT value and SUVmax demonstrated strong reliability [intraclass correlation coefficient (ICC) > 0.80], indicating a robust correlation.
68Ga-PSMA-11 PET/CT demonstrates distinct advantages in identifying aggressive pathological features of primary ccRCC when compared to enhanced CT and 18F-FDG PET/CT. Further research and assessment are warranted to fully establish the clinical utility of 68Ga-PSMA-11 PET/CT in ccRCC.
Chen SH
,Lin BH
,Chen SM
,Qiu QR
,Ruan ZT
,Chen ZJ
,Wei Y
,Zheng QS
,Xue XY
,Miao WB
,Xu N
... -
《-》
-
A prospective head-to-head comparison of [(68)Ga]Ga-P16-093 and [(68)Ga]Ga-PSMA-11 PET/CT in patients with primary prostate cancer.
We aimed to compare the diagnostic performance and biodistribution of two similar PET agents, [68Ga]Ga-P16-093 and [68Ga]Ga-PSMA-11, in the same group of primary prostate cancer (PCa) patients.
Fifty patients with untreated, histologically confirmed PCa by needle biopsy were enrolled. Each patient underwent [68Ga]Ga-P16-093 and [68Ga]Ga-PSMA-11 PET/CT within a week. In addition to visual analysis, the standardized uptake value (SUV) was measured for semiquantitative comparison and correlation analysis.
[68Ga]Ga-P16-093 PET/CT detected more positive tumors than [68Ga]Ga-PSMA-11 PET/CT (202 vs. 190, P = 0.002), both for intraprostatic lesions (48 vs. 41, P = 0.016) and metastatic lesions (154 vs. 149, P = 0.125), especially for intraprostatic lesions in low- and intermediate-risk PCa patients (21/23 vs. 15/23, P = 0.031). Furthermore, [68Ga]Ga-P16-093 PET/CT exhibited a significantly higher SUVmax for most matched tumors (13.7 ± 10.2 vs. 11.4 ± 8.3, P < 0.001). For normal organs, [68Ga]Ga-P16-093 PET/CT showed significantly lower activity in the kidney (SUVmean: 20.1 ± 6.1 vs. 29.3 ± 9.1, P < 0.001) and urinary bladder (SUVmean: 6.5 ± 7.1 vs. 20.9 ± 17.4, P < 0.001), but displayed a higher uptake in the parotid gland (SUVmean: 8.7 ± 2.6 vs. 7.6 ± 2.1, P < 0.001), liver (SUVmean: 7.0 ± 1.9 vs. 3.7 ± 1.3, P < 0.001), and spleen (SUVmean: 8.2 ± 3.0 vs. 5.2 ± 2.2, P < 0.001) than [68Ga]Ga-PSMA-11 PET/CT.
[68Ga]Ga-P16-093 PET/CT demonstrated higher tumor uptake and better tumor detectability than [68Ga]Ga-PSMA-11 PET/CT, especially in low- and intermediate-risk PCa patients, which indicated that [68Ga]Ga-P16-093 may serve as an alternative agent for detection of PCa.
68Ga-P16-093 and 68Ga-PSMA-11 PET/CT Imaging in the Same Group of Primary Prostate Cancer Patients (NCT05324332, Registered 12 April 2022, retrospectively registered). URL OF REGISTRY: https://clinicaltrials.gov/ct2/show/NCT05324332 .
Wang G
,Li L
,Zhu M
,Zang J
,Wang J
,Wang R
,Yan W
,Zhu L
,Kung HF
,Zhu Z
... -
《-》
-
Potential role of (68)Ga-PSMA PET/CT in metastatic renal cell cancer: A prospective study.
Prostate-specific membrane antigen (PSMA), in addition to its utility in prostate cancer, is also an angiogenic imaging marker for hypervascular tumors like renal cell carcinoma (RCC). Our study aims to assess the potential role of 68Ga-PSMA-11 positron emission tomography (PET)/CT in metastatic RCC and compare it with contrast-enhanced computed tomography (CECT).
Biopsy-proven RCC patients with known or suspected distant metastases who underwent 68Ga-PSMA-11 PET/CT for staging/restaging were prospectively recruited. Those patients who had undergone 18F-FDG PET/CT within six weeks of 68Ga-PSMA PET/CT were also included retrospectively for comparative analysis. A patient-based and lesion-based analysis was done to compare the lesion detection rates of CECT, 68Ga-PSMA-11 PET and 18F-FDG PET. PET-based quantitative parameters were also compared between both the PET modalities. Impact of baseline parameters on survival was assessed using Cox regression analysis. A p-value of < 0.05 was considered significant.
Thirty-seven patients with median age 60 years ± 13 years (range = 26-76 years) were included in the study. Twenty-seven patients had clear cell (cc) RCC, six had papillary RCC (pRCC), and one each had an eosinophilic variant of ccRCC, collecting duct RCC, translocation RCC and poorly differentiated RCC. 68Ga-PSMA-11 PET performed better in detecting marrow and equivocal bone lesions and worse in detecting liver lesions compared to CECT. 68Ga-PSMA-11 PET-based angiogenic tumor burden estimation using Total Lesion-PSMA (TL-PSMA) and PSMA-Total volume (PSMA-TV) had a prognostic impact on the survival of patients. 68Ga-PSMA-11 PET also detected more lesions and showed significantly higher SUVmax than 18F-FDG PET.
68Ga-PSMA-11 PET/CT performs better than CECT and 18F-FDG PET/CT in metastatic evaluation and has prognostic value in the management of clear cell RCC.
Aggarwal P
,Singh H
,Das CK
,Mavuduru RS
,Kakkar N
,Lal A
,Gorsi U
,Kumar R
,Mittal BR
... -
《-》