Definition of trAnscatheter heart Valve orIeNtation in biCuspId aortic valve: The DA VINCI pilot study.

来自 PUBMED

摘要:

To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

收起

展开

DOI:

10.3389/fcvm.2022.1056496

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(209)

参考文献(24)

引证文献(4)

来源期刊

Frontiers in Cardiovascular Medicine

影响因子:5.84

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读