A Single-Center Experience with Forearm Arteriovenous Loop Grafts for Hemodialysis.

来自 PUBMED

作者:

Brastauskas IMPatel NGerman ZDavis RPStafford JMEdwards MMurea MGoldman MP

展开

摘要:

Autogenous arteriovenous fistula (AVF) remains the standard of hemodialysis (HD) access; however, it cannot be reasonably obtained in all patients. For patients with contraindications to AVFs, prosthetic arteriovenous graft (AVG) remains an alternative. AVGs are plagued by high failure rates; however, there is a paucity of literature examining this. This study aims to examine a single-center review of outcomes of forearm loop AVGs in patients requiring HD access. A single institution, retrospective chart review was completed from 2012 to 2019, including demographics, end-stage renal disease etiology, brachial vessel diameters, and comorbidities. Logistic regression and Cox proportional hazard models were evaluated. Outcomes were defined as primary patency (time elapsed from graft creation until it was utilized as the patient's primary access), primary-assisted patency (time from primary access to intervention to maintain patency), and functional patency (time from graft placement until graft failure). Additionally, multinomial regression models were used to evaluate associations with categorical number of required interventions. Ninety-eight patients [mean age 61.8 (13.9) years, 42.9% female] were identified as having brachial artery to brachial vein AVG creation during the study period, of which 75% achieved primary patency. Primary-assisted patency was 0.36 [standard error (SE) 0.07] at 6 months and 0.12 (SE 0.05) at 1 year. Functional patency was 0.75 (SE 0.07) at 6 months and 0.43 (SE 0.09) at 1 year. No association between preoperative vessel diameters and primary-assisted or functional patency was observed. Interestingly, there was a significant negative association between previous ipsilateral access and achievement of primary patency with a 60% decrease in odds of achieving primary patency in patients with previous ipsilateral access [odds ratio 0.4, 95% confidence interval (CI) 0.1-0.9, P = 0.03]. There was also noted to be a significant association between the presence of an ipsilateral catheter and increased risk of subsequent abandonment of the AVG (hazard ratio 2.6, 95% CI 1.1-5.8, P = 0.02). Prosthetic forearm loop AVGs remain hindered in their utility as they show high rates of graft failure within a year of creation. A significant patient-specific factor leading to this was not clearly demonstrated. As guidelines change regarding the nature of dialysis access for patients on HD, these results draw into question the utility of prosthetic forearm loop grafts in patients requiring long-term HD access.

收起

展开

DOI:

10.1016/j.avsg.2022.06.003

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(171)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读