Clinical validation of novel lightning dose optimizer for gamma knife radiosurgery of irregular-shaped arteriovenous malformations and pituitary adenomas.

来自 PUBMED

作者:

Pokhrel DBernard MEKnight J 2ndSt Clair WFraser JF

展开

摘要:

To demonstrate the clinical feasibility of a novel treatment planning algorithm via lightning dose optimizer (LDO) on Leksell Gamma Knife (LGK) GammaPlan with significantly faster planning times for stereotactic radiosurgery (SRS) of the complex and difficult arteriovenous malformations (AVMs) and pituitary adenomas. After completing the in-house end-to-end phantom testing and independent dose verification of the recently upgraded LDO algorithm on GammaPlan using the MD Anderson's IROC anthropomorphic SRS head phantom irradiation credentialing, 20 previously treated GK-SRS patients (10 AVM, average volume 3.61 cm3 and 10 pituitary adenomas, average volume 0.86 cm3 ) who underwent manual forward planning on GammaPlan were retrospectively replanned via LDO. These pathologies were included because of the need for adequate dose delivery with organs at risk in very close proximity. LDO finds the target curvature boundary by well-formulated linear programing objectives and inversely optimizes the GK-SRS plan by isocenter placement, optimization, and sequencing. For identical target coverage, the LDO and original manual plans were compared for target conformity, gradient index, dose to critical organs, and surrounding normal brain. Additionally, various treatment delivery parameters, including beam-on time were recorded. For both patient cohorts, LDO provided similar target coverage with better dose conformity, tighter radiosurgical dose distribution with a lower value of gradient indices (all p < 0.001), and lower dose to critical organs. For AVMs, there was a significant reduction of normal brain V10Gy , V12Gy , and V14Gy by 4.74, 3.67, and 2.67 cm3 (all p < 0.001). LDO had twice the number of shots (p < 0.001), and longer beam-on time (p = 0.012) by a factor of 1.44. For pituitary adenomas, LDO provided systematically lower values of V10Gy , V12Gy , and V14Gy by 1.08, 0.86, and 0.68 cm3 (all p < 0.001), and lower maximum dose to optic pathway by 0.7 Gy (p = 0.005), but had almost twice the numbers of shots (p < 0.001) and increased beam-on time (p = 0.005) by a factor of 1.2. However, for both patient groups, the average planning time for the LDO was <5 min, compared to the estimated 30-90 min of manual planning times. GK-SRS treatment on Leksell Perfexion GammaPlan using the LDO provided highly conformal target coverage with a steep dose gradient, spared critical organs, and significantly reduced normal brain dose for complex targets at the cost of slightly higher treatment times. LDO generated high-quality treatment plans and could significantly reduce planning time. If available, the LDO algorithm is suggested for validation and clinical use for complex and difficult GK cases.

收起

展开

DOI:

10.1002/acm2.13669

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(148)

参考文献(24)

引证文献(0)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读