Intra-arc binary collimation with dynamic axes trajectory optimization for the SRS treatment of multiple metastases with multiple prescriptions.

来自 PUBMED

作者:

Lee EMacDonald RLThomas CGSyme A

展开

摘要:

This work generates multi-metastases cranial stereotactic radiosurgery/radiotherapy (SRS/SRT) plans using a novel treatment planning technique in which dynamic couch, collimator, and gantry trajectories are used with periodic binary target collimation. The performance of this planning technique is evaluated against conventional volumetric arc therapy (VMAT) planning in terms of various dose and plan quality metrics. A 3D cost space (referred to herein as the combined optimization of dynamic axes or CODA cube) was calculated based on an overlap between targets and organs-at-risk (OARs) and uncollimated areas between targets (island blocking) for all combinations of couch, gantry, and collimator angles. Gradient descent through the cube was applied to determine dynamic trajectories. At each control point (CP), each target can either be conformally treated or blocked by the multi-leaf collimator (referred to as intra-arc binary collimation, iABC). Simulated annealing was used to optimize the collimation patterns throughout the arcs as well as the monitor units (MUs) delivered at each CP. Seven previously treated VMAT plans were selected for comparison against the CODA-iABC planning technique. Two CODA-iABC plans were developed: a single gantry arc plan and a plan with one gantry arc and two couch arcs. Plan quality comparison metrics included maximum and mean dose to OARs (brainstem, chiasm, optic nerves, eyes, and lenses), the volume of normal brain receiving 12 Gy (V12Gy), total MUs, target conformity, and dose-gradient index. Treatment plans generated with 1-arc CODA-iABC plans delivered an average of 21% and 30% higher maximum and mean doses to brainstem, respectively, when compared to VMAT plans. Treatment plans generated with 3-arc CODA-iABC used an average of 24% fewer MUs and resulted in an average reduction of 48% maximum dose and 50% mean dose to the OARs, when compared to VMAT. Target conformity values were worse in both CODA-iABC plans than VMAT by an average of 35% and 15%, respectively. There are no significant differences in V12Gy for all three planning techniques; however, 3-arc CODA-iABC is more effective at reducing dose to normal brain in the low-dose region (<12 Gy). CODA-iABC is a novel planning technique that has been developed to automatically generate patient-specific multi-axis trajectories for multiple metastases cranial SRS/SRT. This work has demonstrated the feasibility of planning with this novel method. The 1-arc CODA-iABC planning technique is slightly dosimetric inferior to VMAT. With an increased sampling of a three-dimensional CODA cube by using a 3-arc CODA-iABC technique, there was improved total dose sparing to all the OARs and increased MU efficiency, but with a cost in target conformity, when compared to VMAT.

收起

展开

DOI:

10.1002/mp.15689

被引量:

1

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(339)

参考文献(0)

引证文献(1)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读