Early clinical and radiographic outcomes of anatomic total shoulder arthroplasty with a biconvex posterior augmented glenoid for patients with posterior glenoid erosion: minimum 2-year follow-up.

来自 PUBMED

摘要:

Glenoid bone loss in anatomic total shoulder arthroplasty (aTSA) remains a controversial and challenging clinical problem. Previous studies have shown high rates of glenoid loosening for aTSA in shoulders with retroversion, posterior bone loss, and posterior humeral head subluxation. This study is the first to present minimum 2-year follow-up data of an all-polyethylene, biconvex augmented anatomic glenoid component for correction of glenoid retroversion and posterior humeral head subluxation. This study is a multicenter, retrospective review of prospectively collected data on consecutive patients from 7 global clinical sites. All patients underwent aTSA using the biconvex posterior augmented glenoid (PAG). Inclusion criteria were preoperative computed tomographic (CT) scan, minimum 2 years since surgery, preoperative and minimum 2-year postoperative range of motion examination, and patient-reported outcome measures (PROMs). Glenoid classification, glenoid retroversion, and posterior humeral head subluxation were measured from preoperative CT and radiography and postoperative radiography. Statistical comparisons between pre- and postoperative values were performed with a paired t test. Eighty-six of 110 consecutive patients during the study period (78% follow-up) met the inclusion criteria and were included in our analysis. Mean follow-up was 35 ± 10 months, with a mean age of 68 ± 8 years (range 48-85). Range of motion statistically improved in all planes from pre- to postoperation. Mean visual analog scale score improved from 5.2 preoperation to 0.7 postoperation, Single Assessment Numeric Evaluation score from 43.2 to 89.5, Constant score from 41.8 to 76.9, and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score from 49.8 to 86.7 (all P < .0001). Mean glenoid retroversion improved from 19.3° to 7.4° (P < .0001). Posterior subluxation improved from 69.1% to 53.5% and posterior decentering improved from 5.8% to -3.0% (P < .0001). There was 1 patient with both a prosthetic joint infection and radiographic glenoid loosening that required revision. Seventy-nine of 86 patients had a Lazarus score of 0 (no radiolucency seen about peg or keel) at final follow-up. This study shows that at minimum 2-year follow-up, a posterior-augmented all-polyethylene glenoid can correct glenoid retroversion and posterior humeral head subluxation. Clinically, there was significant improvement in both range of motion and PROMs.

收起

展开

DOI:

10.1016/j.jse.2021.12.047

被引量:

3

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(311)

参考文献(0)

引证文献(3)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读