MVCT versus kV-CBCT for targets subject to respiratory motion: A phantom study.

来自 PUBMED

作者:

Baran GDominello MMBossenberger TPaximadis PBurmeister JW

展开

摘要:

The use of kilovoltage cone-beam computed tomography (kV-CBCT) or megavoltage computed tomography (MVCT) for image guidance prior to lung stereotactic body radiation therapy (SBRT) is common clinical practice. We demonstrate that under equivalent respiratory conditions, image guidance using both kV-CBCT and MVCT may result in the inadequate estimation of the range of target motion under free-breathing (FB) conditions when standard low-density window and levels are used. Two spherical targets within a respiratory motion phantom were imaged using both long-exhale (LE) and sinusoidal respiratory traces. MVCT and kV-CBCT images were acquired and evaluated for peak-to-peak amplitudes of 10 or 20 mm in the cranial-caudal direction, and with 2, 4 or 5 s periods. All images were visually inspected for artifacts and conformity to the ITV for each amplitude, period, trace-type, and target size. All LE respiratory traces required a lower threshold HU window for MVCT and kV-CBCT compared to sinusoidal traces to obtain 100% volume conformity compared with the theoretical ITV (ITVT ). Excess volume was less than 2% for all kV-CBCT contours regardless of trace-type, breathing period, or amplitude, while the maximum excess volume for MVCT was 48%. Adjusting window and level to maximize conformity with the ITVT is necessary to reduce registration uncertainty to less than 5 mm. To fully capture target motion with either MVCT or kV-CBCT, substantial changes in HU levels up to -600 HU are required which may not be feasible clinically depending on the target's location and surrounding tissue contrast. This registration method, utilizing a substantially decreased window and level compared to standard low-density settings, was retrospectively compared to the automated registration algorithm for five lung SBRT patients exposed to pre-treatment kV-CBCT image guidance. Differences in registrations in the super-inferior (SI) direction greater than the commonly used ITV to PTV margin of 5 mm were encountered for several cases. In conclusion, pre-treatment image guidance for lung SBRT targets using MVCT or kV-CBCT is unlikely to capture the full extent of target motion as defined by the ITVT and additional caution is warranted to avoid registration errors for small targets and patients with LE respiratory traces.

收起

展开

DOI:

10.1002/acm2.13356

被引量:

1

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(101)

参考文献(31)

引证文献(1)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读