Design and evaluation of 3D printable patient-specific applicators for gynecologic HDR brachytherapy.

来自 PUBMED

作者:

Semeniuk OCherpak ARobar J

展开

摘要:

The purpose of this study is to improve dose distribution and organ-at-risk sparing during gynecologic HDR brachytherapy with patient-specific applicators. The majority of applicators used today are generic in design and do not allow for dose modulation for patient-specific shaping of dose distributions. Their performance might be adjusted with commercially available wedge shields; however, this provides dose modulation in the orthogonal plane only and does not allow for variation along the length of the applicator. Generic applicators are available only in standard sizes and geometries, and provide suboptimal patient fit with limited dose modulation. In this paper we use Monte Carlo modeling for comprehensive characterization of radiologic properties of various 3D printable biocompatible and sterilizable materials with comparison to water. Based on these results, we choose the optimal set of materials for a patient-specific applicator. We develop a novel method to design the patient-specific applicator without incurring a significant increase in treatment time or changes to clinical workflow. Finally, using an example of two selected vaginal cancers, we compare the performance of patient-specific and water-equivalent applicators in terms of target coverage and rectum sparing. In the energy range from 1 MeV to 4 MeV, all materials have similar attenuation coefficients. In the range from ~2 keV to 1 MeV and above 4 MeV, tungsten-polylactic acid composite (WPLA) was seen to have the highest attenuation coefficient. The dose distribution of the water-equivalent applicator was found to be symmetric about its central axis. At the same time patient-specific shielded applicators exhibit well-modulated dose distributions. Their isodose lines are seen to spread radially into the patient, while merging close to the applicator surface, where WPLA shielding has been applied. The patient-specific cylinders provide comparable dose to the target, while offering advanced healthy tissue sparing, not achievable with the generic design.

收起

展开

DOI:

10.1002/mp.14888

被引量:

6

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(161)

参考文献(0)

引证文献(6)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读