Internal fixation implants for intracapsular hip fractures in older adults.

来自 PUBMED

作者:

Lewis SRMacey REardley WGDixon JRCook JGriffin XL

展开

摘要:

Hip fractures are a major healthcare problem, presenting a huge challenge and burden to patients, healthcare systems and society. The increased proportion of older adults in the world population means that the absolute number of hip fractures is rising rapidly across the globe. The majority of hip fractures are treated surgically. This review evaluates evidence for types of internal fixation implants used in joint-preserving surgery for intracapsular hip fractures. To determine the relative effects (benefits and harms) of different implants for the internal fixation of intracapsular hip fractures in older adults. We searched CENTRAL, MEDLINE, Embase, Web of Science, Cochrane Database of Systematic Reviews, Epistemonikos, Proquest Dissertations and Theses, and National Technical Information Service in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles and conducted backward-citation searches. We included randomised controlled trials (RCTs) and quasi-RCTs comparing implants used for internal fixation of fragility intracapsular proximal femoral fractures in older adults. Types of implants were smooth pins (these include pins with fold-out hooks), screws, or fixed angle plates. We excluded studies in which all or most fractures were caused by specific pathologies other than osteoporosis or were the result of a high energy trauma. Two review authors independently assessed studies for inclusion. One review author extracted data and assessed risk of bias which was checked by a second review author. We collected data for seven outcomes: activities of daily living (ADL), delirium, functional status, health-related quality of life (HRQoL), mobility, mortality (reported within four months of surgery as early mortality, and at 12 months since surgery), and unplanned return to theatre for treating a complication resulting directly or indirectly from the primary procedure (such as deep infection or non-union). We assessed the certainty of the evidence for these outcomes using GRADE. We included 38 studies (32 RCTs, six quasi-RCTs) with 8585 participants with 8590 intracapsular fractures. The mean ages of participants in the studies ranged from 60 to 84 years; 73% were women, and 38% of fractures were undisplaced. We report here the findings of the four main comparisons, which were between different categories of implants. We downgraded the certainty of the outcomes for imprecision (when data were available from insufficient numbers of participants or the confidence interval (CI) was wide), study limitations (e.g. high or unclear risks of bias), and inconsistency (when we noted substantial levels of statistical heterogeneity). Smooth pins versus fixed angle plate (four studies, 1313 participants) We found very low-certainty evidence of little or no difference between the two implant types in independent mobility with no more than one walking stick (1 study, 112 participants), early mortality (1 study, 383 participants), mortality at 12 months (2 studies, 661 participants), and unplanned return to theatre (3 studies, 736 participants). No studies reported on ADL, delirium, functional status, or HRQoL. Screws versus fixed angle plates (11 studies, 2471 participants) We found low-certainty evidence of no clinically important differences between the two implant types in functional status using WOMAC (MD -3.18, 95% CI -6.35 to -0.01; 2 studies, 498 participants; range of scores from 0 to 96, lower values indicate better function), and HRQoL using EQ-5D (MD 0.03, 95% CI 0.00 to 0.06; 2 studies, 521 participants; range -0.654 (worst), 0 (dead), 1 (best)). We also found low-certainty evidence showing little or no difference between the two implant types in mortality at 12 months (RR 1.04, 95% CI 0.83 to 1.31; 7 studies, 1690 participants), and unplanned return to theatre (RR 1.10, 95% CI 0.95 to 1.26; 11 studies, 2321 participants). We found very low-certainty evidence of little or no difference between the two implant types in independent mobility (1 study, 70 participants), and early mortality (3 studies, 467 participants). No studies reported on ADL or delirium. Screws versus smooth pins (seven studies, 1119 participants) We found low-certainty evidence of no or little difference between the two implant types in mortality at 12 months (RR 1.07, 95% CI 0.85 to 1.35; 6 studies, 1005 participants; low-certainty evidence). We found very low-certainty evidence of little or no difference between the two implant types in early mortality (3 studies, 584 participants) and unplanned return to theatre (5 studies, 862 participants). No studies reported on ADL, delirium, functional status, HRQoL, or mobility. Screws or smooth pins versus fixed angle plates (15 studies, 3784 participants) In this comparison, we combined data from the first two comparison groups. We found low-certainty evidence of no or little difference between the two groups of implants in mortality at 12 months (RR 1.04, 95% CI.083 to 1.31; 7 studies, 1690 participants) and unplanned return to theatre (RR 1.02, 95% CI 0.88 to 1.18; 14 studies, 3057 participants). We found very low-certainty evidence of little or no difference between the two groups of implants in independent mobility (2 studies, 182 participants), and early mortality (4 studies, 850 participants). We found no additional evidence to support the findings for functional status or HRQoL as reported in 'Screws versus fixed angle plates'. No studies reported ADL or delirium. There is low-certainty evidence that there may be little or no difference between screws and fixed angle plates in functional status, HRQoL, mortality at 12 months, or unplanned return to theatre; and between screws and pins in mortality at 12 months. The limited and very low-certainty evidence for the outcomes for which data were available for the smooth pins versus fixed angle plates comparison, as well as the other outcomes for which data were available for the screws and fixed angle plates, and screws and pins comparisons means we have very little confidence in the estimates of effect for these outcomes. Additional RCTs would increase the certainty of the evidence. We encourage such studies to report outcomes consistent with the core outcome set for hip fracture, including long-term quality of life indicators such as ADL and mobility.

收起

展开

DOI:

10.1002/14651858.CD013409.pub2

被引量:

8

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(189)

参考文献(83)

引证文献(8)

来源期刊

Cochrane Database of Systematic Reviews

影响因子:11.996

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读