The use of tumour markers in oesophageal cancer to quantify setup errors and baseline shifts during treatment.

来自 PUBMED

作者:

Thomas MDe Roover Rvan der Merwe SLambrecht MDefraene GHaustermans K

展开

摘要:

To prospectively evaluate the feasibility of solid gold marker placement in oesophageal cancer patients and to quantify inter-fractional and intra-fractional (baseline shift) marker motion during radiation treatment. Radiotherapy target margins and matching strategies were investigated. Thirty-four markers were implanted by echo-endoscopy in 10 patients. Patients received a planning 4D CT, daily pre-treatment cone-beam CT (CBCT) and a post-treatment CBCT for at least five fractions. For fractions with both pre- and post-treatment CBCT, marker displacement between planning CT and pre-treatment CBCT (inter-fractional) and between pre-treatment and post-treatment CBCT (intra-fractional; only for fractions without rotational treatment couch correction) were calculated in left-right (LR), cranio-caudal (CC) and anterior-posterior (AP) direction after bony-anatomy and soft-tissue matching. Systematic/random setup errors were estimated; treatment margins were calculated. No serious adverse events occurred. Twenty-three (67.6%) markers were visible during radiotherapy (n = 3 middle oesophagus, n = 16 distal oesophagus, n = 4 proximal stomach). Margins for inter-fractional displacement after bony-anatomy match depended on the localisation of the primary tumour and were 11.2 mm (LR), 16.4 mm (CC) and 8.2 mm (AP) for distal markers. Soft-tissue matching reduced the CC margin for these markers (16.4 mm to 10.5 mm). The mean intra-fractional shift of 12 distal markers was 0.4 mm (LR), 2.3 mm (CC) and 0.7 mm (AP). Inclusion of this shift resulted in treatment margins for distal markers of 12.8 mm (LR), 17.3 mm (CC) and 10.4 mm (AP) after bony-anatomy matching and 12.4 mm (LR), 11.4 mm (CC) and 9.7 mm (AP) after soft-tissue matching. This study demonstrated that the implantation of gold markers was safe, albeit less stable compared to other marker types. Inter-fractional motion was largest cranio-caudally for markers in the distal oesophagus, which was reduced after soft-tissue compared to bony-anatomy matching. The impact of intra-fractional baseline shifts on margin calculation was rather small.

收起

展开

DOI:

10.1016/j.ctro.2020.11.001

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(181)

参考文献(35)

引证文献(0)

来源期刊

Clinical and Translational Radiation Oncology

影响因子:4.734

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读