-
Unexpected high frequency of unspecific reactivities by testing pre-epidemic blood specimens from Europe and Africa with SARS-CoV-2 IgG-IgM antibody rapid tests points to IgM as the Achilles heel.
We aimed to evaluate the rates of false-positive test results of three rapid diagnostic tests (RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-specific immunoglobulin G (IgG) and IgM detection. Two serum panels from patients hospitalized in Paris, France, and from patients living in Bangui, Central African Republic, acquired before the 2019 COVID-19 outbreak, were tested by 3 CE IVD-labeled RDTs for SARS-CoV-2 serology (BIOSYNEX® COVID-19 BSS [IgG/IgM]; SIENNA™ COVID-19 IgG/IgM Rapid Test Cassette; NG-Test® IgG-IgM COVID-19). Detectable IgG or IgM reactivities could be observed in 31 (3.43%) of the 902 IgG and IgM bands of the 3 RDTs used with all pre-epidemic sera. The frequencies of IgG/IgM reactivities were similar for European (3.20%) and African (3.55%) sera. IgM reactivities were observed in 9 European and 14 African sera, while IgG reactivity was observed in only 1 African serum (15.1% vs. 0.66%). The test NG-Test® IgG-IgM COVID-19 showed the highest rates of IgG or IgM reactivities (6.12% [18/294]), while the test BIOSYNEX® COVID-19 BSS (IgG/IgM) showed the lowest rate (1.36% [4/294]). Some combinations of 2 RDTs in series allowed decreasing significantly the risk of false-positive test results. Our observations point to the risk of false-positive reactivities when using currently available RDT for SARS-CoV-2 serological screening, especially for the IgM band, even if the test is CE IVD-labeled and approved by national health authorities, and provide the rational basis for confirmatory testing by another RDT in case of positive initial screening.
Mboumba Bouassa RS
,Péré H
,Tonen-Wolyec S
,Longo JD
,Moussa S
,Mbopi-Keou FX
,Mossoro-Kpinde CD
,Grésenguet G
,Veyer D
,Bélec L
... -
《-》
-
Analytical performances of five SARS-CoV-2 whole-blood finger-stick IgG-IgM combined antibody rapid tests.
Facing the ongoing pandemic caused by SARS-CoV-2, there is an urgent need for serological assays identifying individuals previously infected by coronavirus disease 2019 (COVID-19), including rapid diagnostic tests (RDTs). We herein compared five new CE-IVD-labeled commercially available SARS-CoV-2 whole-blood finger-stick IgG/IgM combined RDTs, in parallel according to the manufacturers' instructions, with two serum panels obtained from 48 patients with confirmed COVID-19 (panel I) and from a group of 52 patients randomly selected, for whom serum samples collected before the COVID-19 epidemic (from October 1 to November 30, 2019) were negative for SARS-CoV-2 IgG (panel II). We found a sensitivity of 95.8 %, 91.6 %, 92.3 %, 97.9 % and 91.4 %, and a specificity of 98.1 %, 86.5 %, 100 %, 98.1 % and 84.6 %, for BIOSYNEX COVID-19 BSS (IgG/IgM) (Biosynex Swiss SA, Freiburg, Switzerland), Humasis COVID-19 IgG/IgM Test (Humasis Co., Ltd., Gyneonggi, Republic of Korea), LYHER COVID-19 IgM/IgG Rapid Test (Medakit Ltd, Hong Kong, China), SIENNA™ COVID-19 (IgG/IgM) Rapid Test Cassette (Salofa Oy, Salo, Finland) and NG-BIOTECH COVID-19 (IgG/IgM) (NG-Biotech, Guipry, France), respectively. Commercially available SARS-CoV-2 IgG/IgM combined RDTs have a sufficient sensitivity for identifying individuals with past SARS-CoV-2 infection, but some RDTs may lack of specificity, with risk of false positivity mainly for the IgM band.
Péré H
,Mboumba Bouassa RS
,Tonen-Wolyec S
,Podglajen I
,Veyer D
,Bélec L
... -
《-》
-
Performance evaluation of two SARS-CoV-2 IgG/IgM rapid tests (Covid-Presto and NG-Test) and one IgG automated immunoassay (Abbott).
The aim of this study was to assess the analytical performances, sensitivity and specificity, of two rapid tests (Covid- Presto® test rapid Covid-19 IgG/IgM and NG-Test® IgM-IgG COVID-19) and one automated immunoassay (Abbott SARS-CoV-2 IgG) for detecting anti- SARS-CoV-2 antibodies. This study was performed with: (i) a positive panel constituted of 88 SARS-CoV-2 specimens collected from patients with a positive SARS-CoV-2 RT-PCR, and (ii) a negative panel of 120 serum samples, all collected before November 2019, including 64 samples with a cross-reactivity panel. Sensitivity of Covid-Presto® test for IgM and IgG was 78.4% and 92.0%, respectively. Sensitivity of NG-Test® for IgM and IgG was 96.6% and 94.9%, respectively. Sensitivity of Abbott IgG assay was 96.5% showing an excellent agreement with the two rapid tests (κ = 0.947 and κ = 0.936 for NGTest ® and Covid-Presto® test, respectively). An excellent agreement was also observed between the two rapid tests (κ = 0.937). Specificity for IgM was 100% and 86.5% for Covid-Presto® test and NG-Test®, respectively. Specificity for IgG was 92.0%, 94.9% and 96.5% for Covid-Presto®, NGTest ®, and Abbott, respectively. Most of the false positive results observed with NG-Test® resulted from samples containing malarial antibodies. In conclusion, performances of these 2 rapid tests are very good and comparable to those obtained with automated immunoassay, except for IgM specificity with the NG-Test®. Thus, isolated IgM should be cautiously interpreted due to the possible false-positive reactions with this test. Finally, before their large use, the rapid tests must be reliably evaluated with adequate and large panel including early seroconversion and possible cross-reactive samples.
Charpentier C
,Ichou H
,Damond F
,Bouvet E
,Chaix ML
,Ferré V
,Delaugerre C
,Mahjoub N
,Larrouy L
,Le Hingrat Q
,Visseaux B
,Mackiewicz V
,Descamps D
,Fidouh-Houhou N
... -
《-》
-
Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting.
While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performance of SARS-CoV-2 antibody assays in Nigeria and so we evaluated the diagnostic performance of five (5) immunoassay on a set of clinical samples. Five automated immunoassays (2019-nCoV IgG/IgM antibody determination kit, Tigsun COVID-19 combo IgM/IgG rapid test, rapid response COVID-19 IgG/IgM test, COVID-19 IgM-IgG combined antibody rapid test, iChroma COVID-19 Ab) were tested. Three hundred and fourteen specimens were analyzed from health care workers who tested positive PCR for SARS-CoV-2 with symptoms consistent with SARS-CoV-2 receiving treatment at two treatment centres in Nasarawa State from March to September, 2020 with control of 134 health care workers who tested negative PCR for SARS-CoV-2 with no symptoms to SARS-CoV-2. The median patients' age was 40 years (IQR 39.8-41), majority were male and were on admission. The SARS-CoV-2 IgG/IgM antibody evaluated kits had a sensitivity of 33% (2019-nCoV IgG/IgM antibody determination kit), 22% (Tigsun COVID-19 combo IgM/IgG rapid test), 43% (rapid response COVID-19 IgG/IgM test), 44% (COVID-19 IgM-IgG combined antibody rapid test), 25% (iChroma COVID-19 Ab), 100% sensitivity, accuracy of 68.5% and Kappa coefficient of 0.7 and rapid response COVID-19 IgG/IgM test cassette had a sensitivity of 33%, specificity of 100% and accuracy of 72.5% with Kappa coefficient 0.7. The Tigsun COVID-19 combo IgM/IgG rapid test (lateral flow), positive, COVID-19 IgM-IgG combined antibody rapid test and iChroma COVID-19 Ab RT all had sensitivity of zero percent. Serology was complementary to RT-PCR for the diagnosis of COVID-19 at least 14 days after onset of symptoms. The assay panel needs to be improved to serve as an option for the diagnosis of SARS-CoV-2 in resource constrained settings where there are limited molecular diagnostics testing panels.
Akyala AI
,Awayimbo JR
,Ogo AC
,Chima NJ
,Billyrose OMA
,Engom AOG
... -
《-》
-
False-positive results of SARS-CoV-2 IgM/IgG antibody tests in sera stored before the 2020 pandemic in Italy.
Aside from the outbreak of the coronavirus disease 2019 (COVID-19), serological tests are not well known for their diagnostic value. We assessed the performance of serological tests using stored sera from patients with a variety of pathologic conditions, collected before the 2020 pandemic in Italy.
Rapid lateral flow tests and Enzyme-Linked Immunosorbent Assays (ELISA) that detect Immunoglobulin M (IgM) and Immunoglobulin G (IgG) antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) were carried out using 1150 stored human serum samples that had been collected in 2018 and 2019. The tests were also run using samples from 15 control patients who had positive or negative oral swab test results, as assessed using real-time reverse transcription-polymerase chain reaction (rRT-PCR). The urea dissociation test was employed to rule out false-positive reactivity in the two antibody detection methods.
The lateral flow tests revealed 21 positive samples from the stored sera: 12 for IgM, four for IgG, and five for IgM/IgG. Among the nine rRT-PCR- positive controls, six individuals presented IgG and three IgM/IgG positivity. Using the urea (6 mol/L) dissociation test, two of the twelve stored samples that had shown IgM positivity were confirmed to be positive. The ELISA test detected four IgM-positive and three IgG-positive specimens. After treatment with 4 mol/L urea, the IgM-positive samples became negative, whereas the IgG positivity persisted. All of the rRT-PCR-positive controls were found to retain IgM or IgG positivity following the urea treatment.
Our findings highlight the limited utility of serological testing for the SARS-CoV-2 virus based on the results of specimens collected before the outbreak of the infection.
Latiano A
,Tavano F
,Panza A
,Palmieri O
,Niro GA
,Andriulli N
,Latiano T
,Corritore G
,Gioffreda D
,Gentile A
,Fontana R
,Guerra M
,Biscaglia G
,Bossa F
,Carella M
,Miscio G
,di Mauro L
... -
《-》