Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients.

来自 PUBMED

作者:

Puel FCrognier LSoulé CVardon-Bounes FRuiz SSeguin TFourcade OMinville VConil JMGeorges B

展开

摘要:

Ultra-protective ventilation with low tidal volume is used in severe acute respiratory distress syndrome (ARDS) patients under extracorporeal membrane oxygenation (ECMO). However, the optimal positive end-expiratory pressure (PEEP) is unknown. The aim of our study was to assess electrical impedance tomography's (EIT) ability to choose the best PEEP for these patients. A recruitment maneuver and after a decremental PEEP trial from 20 to 5 cmH20 were monitored by EIT, with lung images divided into four ventral-to-dorsal horizontal regions of interest. For each patient, three EIT-based PEEP were defined: PEEP ODCLmin (lowest pressure with the least EIT-based collapse lung [CL] and overdistension [OD]), PEEP ODCL15 (lowest pressure able to limit EIT-based collapse to less than or equal to 15% with the least overdistension) and PEEP Comp (PEEP with the highest EIT-based compliance). High PEEP levels were significantly associated with more overdistension while decreasing PEEP led to more collapsed zones. PEEP ODCL15 and PEEP Comp were in complete agreement with the reference Pulmonary PEEP (chosen according to usual respiratory clinical and ultrasound criteria), PEEP ODCLmin was in average agreement with the Pulmonary PEEP. EIT may be a useful real-time monitoring technique to optimize the PEEP level in severe ARDS patients under ECMO. Ultra-protective ventilation with low tidal volume is used in severe acute respiratory distress syndrome patients under extracorporeal membrane oxygenation (ECMO), but the optimal positive end-expiratory pressure is unknown. This trial shows that electrical impedance tomography may be an interesting non-invasive bedside tool to provide real-time monitoring of PEEP impact in severe ARDS patients under ECMO. The Pulmovista® electrical impedance tomography was provided by Dräger (Lübeck, Germany) during the study period. Dräger had no role in the study design, collection, analysis and interpretation of the data, writing the article, or the decision to submit the article for publication.

收起

展开

DOI:

10.1016/j.jcrc.2020.06.017

被引量:

7

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(1057)

参考文献(0)

引证文献(7)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读