Dosimetric quality and delivery efficiency of robotic radiosurgery for brain metastases: Comparison with C-arm linear accelerator based plans.

来自 PUBMED

作者:

Zhang SYang RWang X

展开

摘要:

The incidence of brain metastases is increasing and various treatment modalities exist for brain metastases. The aim of this study was to investigate the dosimetric quality and delivery efficiency of robotic radiosurgery (CyberKnife) for multiple brain metastases compared with C-arm linear accelerator (linac) based plans. C-arm linac based plans included intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and non-coplanar VMAT with 1, 3 and 5 non-coplanar arcs, respectively (NC1, NC3 and NC5). For 20 patients, six plans with a prescription dose of 30 Gy in three fractions were generated. The gradient index (GI), conformity index (CI), maximum dose (Dmax ) of organs at risk (OARs), normal brain tissue volume (V3 Gy -V24 Gy ), monitor units (MUs) and beam on time (BT) were evaluated. The GI of CyberKnife plans (3.60 ± 0.70) was lower than IMRT (6.21 ± 2.26, P < 0.05), VMAT (6.04 ± 1.93, P < 0.05), NC1 (5.16 ± 1.71, P < 0.05), NC3 (5.02 ± 1.59, P < 0.05) and NC5 (5.03 ± 1.72, P < 0.05). The CI of the VMAT plans (both coplanar and non-coplanar) was larger than IMRT and CK plans. The Dmax for most OARs of the CyberKnife plan was lower than the C-arm linac based plans, although some differences were not statistically significant. The normal brain tissue volume of CyberKnife plan was lower than the C-arm linac based plans, and the normal brain tissue volume of non-coplanar VMAT plans was lower than IMRT and VMAT plans at high-moderate dose level. However, the MUs and BT of CyberKnife plans was more than C-arm linac based plans. CyberKnife plan was better than C-arm linac based plans in protecting normal brain tissue and OARs for patients with multiple brain metastases. C-arm linac based plan with non-coplanar arc provided better protection of normal brain tissue than coplanar plan. However, the BT of CyberKnife plan was longer than C-arm linac based plans.

收起

展开

DOI:

10.1002/acm2.12746

被引量:

7

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(643)

参考文献(34)

引证文献(7)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读