Quantifying the accuracy of deformable image registration for cone-beam computed tomography with a physical phantom.

来自 PUBMED

作者:

Wu RYLiu AYWilliamson TDYang JWisdom PGZhu XRFrank SJFuller CDGunn GBGao S

展开

摘要:

Kilo-voltage cone-beam computed tomography (CBCT) is widely used for patient alignment, contour propagation, and adaptive treatment planning in radiation therapy. In this study, we evaluated the accuracy of deformable image registration (DIR) for CBCT under various imaging protocols with different noise and patient dose levels. A physical phantom previously developed to facilitate end-to-end testing of the DIR accuracy was used with Varian Velocity v4.0 software to evaluate the performance of image registration from CT to CT, CBCT to CT, and CBCT to CBCT. The phantom is acrylic and includes several inserts that simulate different tissue shapes and properties. Deformations and anatomic changes were simulated by changing the rotations of both the phantom and the inserts. CT images (from a head and neck protocol) and CBCT images (from pelvis, head and "Image Gently" protocols) were obtained with different image noise and dose levels. Large inserts were filled with Mobil DTE oil to simulate soft tissue, and small inserts were filled with bone materials. All inserts were contoured before the DIR process to provide a ground truth contour size and shape for comparison. After the DIR process, all deformed contours were compared with the originals using Dice similarity coefficient (DSC) and mean distance to agreement (MDA). Both large and small volume of interests (VOIs) for DIR volume selection were tested by simulating a DIR process that included whole patient image volume and clinical target volumes (CTV) only (for CTVs propagation). For cross-modality DIR registration (CT to CBCT), the DSC were >0.8 and the MDA were <3 mm for CBCT pelvis, and CBCT head protocols. For CBCT to CBCT and CT to CT, the DIR accuracy was improved relative to the cross-modality tests. For smaller VOIs, the DSC were >0.8 and MDA <2 mm for all modalities. The accuracy of DIR depends on the quality of the CBCT image at different dose and noise levels.

收起

展开

DOI:

10.1002/acm2.12717

被引量:

8

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(422)

参考文献(28)

引证文献(8)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读