Comparison of underivatized silica and zwitterionic sulfobetaine hydrophilic interaction liquid chromatography stationary phases for global metabolomics of human plasma.

来自 PUBMED

作者:

Sonnenberg RANaz SCougnaud LVuckovic D

展开

摘要:

To increase metabolome coverage in global LC-MS metabolomics, often both reversed-phase liquid chromatography (RPLC) and hydrophilic-interaction liquid chromatography (HILIC) are implemented in parallel. However, there is a lack of consensus in the literature on the best HILIC stationary phase to employ for global metabolomics of human biological fluids. The objective of this study was to compare in detail the performance of two commonly employed HILIC phases: zwitterionic sulfobetaine ZIC-HILIC stationary phase and an underivatized silica HILIC stationary phase. During method development, the effect of salt concentration in the mobile phase was also investigated, and 5 mM ammonium acetate was selected. The stationary phases were evaluated using a mixture of 37 polar standards covering a range of logP values (-10 to 3.73), molecular weights (59-776 Da), charges (15 anions, 11 cations, and 11 neutral) as well as 17 lipid standards to understand phospholipid behaviour on the two stationary phases. The criteria used for the comparison included the quality of the chromatographic peak shape, adequate analyte retention, peak separation capability, and metabolite coverage. The zwitterionic ZIC-HILIC column provided better chromatographic performance over the silica stationary phase with 14 standards achieving good quality peaks compared to the 7 with the silica column. Only 2 standards were undetected with the ZIC-HILIC column compared to the 14 undetected with the silica column. In human plasma, 1966 and 1650 metabolites were observed on the ZIC-HILIC column in positive and negative electrospray ionization (ESI) respectively. On the silica HILIC column, 1773 and 2028 metabolites were observed in positive and negative ESI respectively, showing comparable performance of the two phases. Next, the effect of adding 10 mM ammonium phosphate to the samples to improve the analyte peak shape and metabolite coverage was investigated for both ZIC-HILIC and silica HILIC. In contrast with recently reported results for pZIC-HILIC, there was no clear evidence that ammonium phosphate addition was beneficial for human plasma samples. In conclusion, ZIC-HILIC provided better chromatographic performance for polar plasma metabolomics than underivatized silica in terms of chromatographic peak shape and chromatographic resolution, while maintaining comparable metabolite coverage. The addition of ammonium phosphate to human plasma was not beneficial for either of the two stationary phases.

收起

展开

DOI:

10.1016/j.chroma.2019.460419

被引量:

6

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(780)

参考文献(0)

引证文献(6)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读