Long-term results after standard endovascular aneurysm repair with the Endurant and Excluder stent grafts.

来自 PUBMED

摘要:

Many endografts are currently available for standard endovascular repair of infrarenal abdominal aortic aneurysms. Comparison of long-term outcomes between devices might aid in this decision process, but comparative data are scarce. The purpose of this study was to report long-term clinical outcomes of two commercially available endoprosthesis, the Endurant (Medtronic Vascular, Inc, Minneapolis, Minn) and the Excluder (W. L. Gore & Associates, Flagstaff, Ariz) stent grafts. Patients undergoing standard endovascular repair from July 2004 to December 2011 in a single institution with the Endurant or the Low-Porosity Excluder endografts were eligible. Only patients treated for intact degenerative abdominal infrarenal aneurysms were included. All measurements were performed on center-lumen line reconstructions obtained on dedicated software. The primary end point was primary clinical success, defined as clinical success without the need for an additional or secondary surgical or endovascular procedure. Neck-related events (a composite of type IA endoleak, neck-related secondary intervention, or migration of >5 mm), neck morphology changes, renal function, and overall survival were secondary end points. The study included 277 patients (156 Endurants; 121 Excluders). The median follow-up was 5.8 years (range, 0.1-12.4 years) and did not differ between groups (P = .18). Patients treated with the Endurant stent graft had wider (neck diameter of >28 mm, 27.3% vs 1.7% [P < .001]; neck diameter of 27 mm, [interquartile range (IQR), 24-29 mm] for Endurant and 24 mm [IQR, 22-25 mm] for Excluder; P < .001) and more angulated necks (β-angle of >60°, 26.7% vs 12.5%; P = .004). Oversizing was greater in the Endurant group (16% [IQR, 12%-22%] vs 13% [IQR, 8%-17%], respectively; P < .001). Patients were treated outside device instructions for use regarding proximal neck: 16.7% in the Endurant and 17.3% in the Excluder group (P = .720). The 7-year primary clinical success was 54.7% for the Endurant and 58.1% for the Excluder groups (P = .53). Freedom from neck-related events at 7 years was 76.7% for the Endurant and 78.8% for Excluder group (P = .94). The Endurant stent graft (hazard ratio [HR], 2.7; 95% confidence interval [CI], 1.3-5.8; P = .009) was an independent predictor of significant renal function decline. Neck dilatation was greater in Endurant-implanted patients (13% [95% CI, 2%-22%] vs 4% [95% CI, 0%-10%]; P < .001). Overall survival at 7 years was 61.4% in the Endurant and 50.3% (n = 50; standard error, 0.047) in the Excluder group (P = .39). This study reveals that durable and sustainable results can be obtained with either of these late generation devices. This finding suggests that careful planning and a tailored device selection taking into account the patient's anatomy are more relevant determinants than the graft model itself to obtain clinical success. The Endurant endoprosthesis seems to be associated with a higher rate of neck dilatation and faster decrease in the estimated glomerular filtration rate, but further studies with longer follow-up are necessary to determine the clinical relevance of these findings.

收起

展开

DOI:

10.1016/j.jvs.2019.03.039

被引量:

12

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(350)

参考文献(0)

引证文献(12)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读