Factors that affect ultrasound-determined labor progress in women undergoing induction of labor.

来自 PUBMED

作者:

Chaemsaithong PKwan AHWTse WTLim WTChan WWYChong KCLeung TYPoon LC

展开

摘要:

The traditional approach to the assessment of labor progress is by digital vaginal examination; however, it is subjective and imprecise. Recent studies have investigated the role of transperineal ultrasonographic assessment of fetal head descent by measuring the angle of progression and head-perineum distance. The objective of this study was to evaluate factors that affected labor progress, which were defined by the transperineal ultrasonographic parameters, in women who achieved vaginal delivery. This was a prospective longitudinal study performed in 315 women with singleton pregnancy who underwent labor induction at term between December 2016 and December 2017. Paired assessment of cervical dilation and fetal head station by vaginal examination and transperineal ultrasonographic assessment of fetal head descent (parasagittal angle of progression and head-perineum distance) were made serially after the commencement of labor induction until full cervical dilation. The researchers were blinded to the findings of the clinical team's vaginal examination and vice versa. The repeated measure data were analyzed by mixed effect models to identify the significant factors (age ≥35 years, obesity, parity, methods of labor induction, and epidural anesthesia) that affected the relationship between parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation. The total number of paired vaginal examination and transperineal ultrasonographic assessments among the 261 women (82.9%) with vaginal delivery was 945, with a median of 3 per woman. The median assessment-to-assessment interval was 4.6 hours (interquartile range, 4.3-5.2). Multiparity and mechanical methods of labor induction were associated with a faster rate of fetal head descent, which was determined by head-perineum distance against fetal head station, than nulliparity and the use of a slow-release vaginal pessary, respectively. An additional increase of 0.10 cm in head-perineum distance was observed, for an unit increase in fetal head station in nulliparous women (P=.03) and women who had a slow-release vaginal pessary (P=.02), compared with multiparous women and those who had mechanical methods for labor induction. The use of epidural anesthesia was associated with a slower rate of fetal head descent, which was determined by both parasagittal angle of progression and head-perineum distance, against fetal head station. An additional decrease of 3.66 degrees in parasagittal angle of progression (P=.04) and an additional increase in 0.33 cm in head-perineum distance (P≤.001) were observed for a unit increase in fetal head station in women with the use of epidural anesthesia, compared with those without. Obese women had higher head-perineum distance overall, compared with normal weight women; at different cross-sections of time periods, obesity appeared to be associated with a slower rate of change between head-perineum distance and cervical dilation. Advanced maternal age did not affect transperineal ultrasound-determined labor progress (P>.05). Parity, methods of labor induction, the use of epidural anesthesia, and obesity affect labor progress, which has been illustrated objectively by serial transperineal ultrasonographic assessment of fetal head descent.

收起

展开

DOI:

10.1016/j.ajog.2019.01.236

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(432)

参考文献(0)

引证文献(2)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读