Xpert(®) MTB/RIF assay for extrapulmonary tuberculosis and rifampicin resistance.


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(3007)
参考文献(191)
引证文献(136)
-
Xpert(®) MTB/RIF assay for extrapulmonary tuberculosis and rifampicin resistance.
Kohli M ,Schiller I ,Dendukuri N ,Dheda K ,Denkinger CM ,Schumacher SG ,Steingart KR ... - 《Cochrane Database of Systematic Reviews》
被引量: 136 发表:1970年 -
Xpert MTB/RIF Ultra (Xpert Ultra) and Xpert MTB/RIF are World Health Organization (WHO)-recommended rapid nucleic acid amplification tests (NAATs) widely used for simultaneous detection of Mycobacterium tuberculosis complex and rifampicin resistance in sputum. To extend our previous review on extrapulmonary tuberculosis (Kohli 2018), we performed this update to inform updated WHO policy (WHO Consolidated Guidelines (Module 3) 2020). To estimate diagnostic accuracy of Xpert Ultra and Xpert MTB/RIF for extrapulmonary tuberculosis and rifampicin resistance in adults with presumptive extrapulmonary tuberculosis. Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, Web of Science, Latin American Caribbean Health Sciences Literature, Scopus, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform, the International Standard Randomized Controlled Trial Number Registry, and ProQuest, 2 August 2019 and 28 January 2020 (Xpert Ultra studies), without language restriction. Cross-sectional and cohort studies using non-respiratory specimens. Forms of extrapulmonary tuberculosis: tuberculous meningitis and pleural, lymph node, bone or joint, genitourinary, peritoneal, pericardial, disseminated tuberculosis. Reference standards were culture and a study-defined composite reference standard (tuberculosis detection); phenotypic drug susceptibility testing and line probe assays (rifampicin resistance detection). Two review authors independently extracted data and assessed risk of bias and applicability using QUADAS-2. For tuberculosis detection, we performed separate analyses by specimen type and reference standard using the bivariate model to estimate pooled sensitivity and specificity with 95% credible intervals (CrIs). We applied a latent class meta-analysis model to three forms of extrapulmonary tuberculosis. We assessed certainty of evidence using GRADE. 69 studies: 67 evaluated Xpert MTB/RIF and 11 evaluated Xpert Ultra, of which nine evaluated both tests. Most studies were conducted in China, India, South Africa, and Uganda. Overall, risk of bias was low for patient selection, index test, and flow and timing domains, and low (49%) or unclear (43%) for the reference standard domain. Applicability for the patient selection domain was unclear for most studies because we were unsure of the clinical settings. Cerebrospinal fluid Xpert Ultra (6 studies) Xpert Ultra pooled sensitivity and specificity (95% CrI) against culture were 89.4% (79.1 to 95.6) (89 participants; low-certainty evidence) and 91.2% (83.2 to 95.7) (386 participants; moderate-certainty evidence). Of 1000 people where 100 have tuberculous meningitis, 168 would be Xpert Ultra-positive: of these, 79 (47%) would not have tuberculosis (false-positives) and 832 would be Xpert Ultra-negative: of these, 11 (1%) would have tuberculosis (false-negatives). Xpert MTB/RIF (30 studies) Xpert MTB/RIF pooled sensitivity and specificity against culture were 71.1% (62.8 to 79.1) (571 participants; moderate-certainty evidence) and 96.9% (95.4 to 98.0) (2824 participants; high-certainty evidence). Of 1000 people where 100 have tuberculous meningitis, 99 would be Xpert MTB/RIF-positive: of these, 28 (28%) would not have tuberculosis; and 901 would be Xpert MTB/RIF-negative: of these, 29 (3%) would have tuberculosis. Pleural fluid Xpert Ultra (4 studies) Xpert Ultra pooled sensitivity and specificity against culture were 75.0% (58.0 to 86.4) (158 participants; very low-certainty evidence) and 87.0% (63.1 to 97.9) (240 participants; very low-certainty evidence). Of 1000 people where 100 have pleural tuberculosis, 192 would be Xpert Ultra-positive: of these, 117 (61%) would not have tuberculosis; and 808 would be Xpert Ultra-negative: of these, 25 (3%) would have tuberculosis. Xpert MTB/RIF (25 studies) Xpert MTB/RIF pooled sensitivity and specificity against culture were 49.5% (39.8 to 59.9) (644 participants; low-certainty evidence) and 98.9% (97.6 to 99.7) (2421 participants; high-certainty evidence). Of 1000 people where 100 have pleural tuberculosis, 60 would be Xpert MTB/RIF-positive: of these, 10 (17%) would not have tuberculosis; and 940 would be Xpert MTB/RIF-negative: of these, 50 (5%) would have tuberculosis. Lymph node aspirate Xpert Ultra (1 study) Xpert Ultra sensitivity and specificity (95% confidence interval) against composite reference standard were 70% (51 to 85) (30 participants; very low-certainty evidence) and 100% (92 to 100) (43 participants; low-certainty evidence). Of 1000 people where 100 have lymph node tuberculosis, 70 would be Xpert Ultra-positive and 0 (0%) would not have tuberculosis; 930 would be Xpert Ultra-negative and 30 (3%) would have tuberculosis. Xpert MTB/RIF (4 studies) Xpert MTB/RIF pooled sensitivity and specificity against composite reference standard were 81.6% (61.9 to 93.3) (377 participants; low-certainty evidence) and 96.4% (91.3 to 98.6) (302 participants; low-certainty evidence). Of 1000 people where 100 have lymph node tuberculosis, 118 would be Xpert MTB/RIF-positive and 37 (31%) would not have tuberculosis; 882 would be Xpert MTB/RIF-negative and 19 (2%) would have tuberculosis. In lymph node aspirate, Xpert MTB/RIF pooled specificity against culture was 86.2% (78.0 to 92.3), lower than that against a composite reference standard. Using the latent class model, Xpert MTB/RIF pooled specificity was 99.5% (99.1 to 99.7), similar to that observed with a composite reference standard. Rifampicin resistance Xpert Ultra (4 studies) Xpert Ultra pooled sensitivity and specificity were 100.0% (95.1 to 100.0), (24 participants; low-certainty evidence) and 100.0% (99.0 to 100.0) (105 participants; moderate-certainty evidence). Of 1000 people where 100 have rifampicin resistance, 100 would be Xpert Ultra-positive (resistant): of these, zero (0%) would not have rifampicin resistance; and 900 would be Xpert Ultra-negative (susceptible): of these, zero (0%) would have rifampicin resistance. Xpert MTB/RIF (19 studies) Xpert MTB/RIF pooled sensitivity and specificity were 96.5% (91.9 to 98.8) (148 participants; high-certainty evidence) and 99.1% (98.0 to 99.7) (822 participants; high-certainty evidence). Of 1000 people where 100 have rifampicin resistance, 105 would be Xpert MTB/RIF-positive (resistant): of these, 8 (8%) would not have rifampicin resistance; and 895 would be Xpert MTB/RIF-negative (susceptible): of these, 3 (0.3%) would have rifampicin resistance. Xpert Ultra and Xpert MTB/RIF may be helpful in diagnosing extrapulmonary tuberculosis. Sensitivity varies across different extrapulmonary specimens: while for most specimens specificity is high, the tests rarely yield a positive result for people without tuberculosis. For tuberculous meningitis, Xpert Ultra had higher sensitivity and lower specificity than Xpert MTB/RIF against culture. Xpert Ultra and Xpert MTB/RIF had similar sensitivity and specificity for rifampicin resistance. Future research should acknowledge the concern associated with culture as a reference standard in paucibacillary specimens and consider ways to address this limitation.
Kohli M ,Schiller I ,Dendukuri N ,Yao M ,Dheda K ,Denkinger CM ,Schumacher SG ,Steingart KR ... - 《Cochrane Database of Systematic Reviews》
被引量: - 发表:1970年 -
Every year, at least one million children become ill with tuberculosis and around 200,000 children die. Xpert MTB/RIF and Xpert Ultra are World Health Organization (WHO)-recommended rapid molecular tests that simultaneously detect tuberculosis and rifampicin resistance in adults and children with signs and symptoms of tuberculosis, at lower health system levels. To inform updated WHO guidelines on molecular assays, we performed a systematic review on the diagnostic accuracy of these tests in children presumed to have active tuberculosis. Primary objectives • To determine the diagnostic accuracy of Xpert MTB/RIF and Xpert Ultra for (a) pulmonary tuberculosis in children presumed to have tuberculosis; (b) tuberculous meningitis in children presumed to have tuberculosis; (c) lymph node tuberculosis in children presumed to have tuberculosis; and (d) rifampicin resistance in children presumed to have tuberculosis - For tuberculosis detection, index tests were used as the initial test, replacing standard practice (i.e. smear microscopy or culture) - For detection of rifampicin resistance, index tests replaced culture-based drug susceptibility testing as the initial test Secondary objectives • To compare the accuracy of Xpert MTB/RIF and Xpert Ultra for each of the four target conditions • To investigate potential sources of heterogeneity in accuracy estimates - For tuberculosis detection, we considered age, disease severity, smear-test status, HIV status, clinical setting, specimen type, high tuberculosis burden, and high tuberculosis/HIV burden - For detection of rifampicin resistance, we considered multi-drug-resistant tuberculosis burden • To compare multiple Xpert MTB/RIF or Xpert Ultra results (repeated testing) with the initial Xpert MTB/RIF or Xpert Ultra result SEARCH METHODS: We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Scopus, the WHO International Clinical Trials Registry Platform, ClinicalTrials.gov, and the International Standard Randomized Controlled Trials Number (ISRCTN) Registry up to 29 April 2019, without language restrictions. Randomized trials, cross-sectional trials, and cohort studies evaluating Xpert MTB/RIF or Xpert Ultra in HIV-positive and HIV-negative children younger than 15 years. Reference standards comprised culture or a composite reference standard for tuberculosis and drug susceptibility testing or MTBDRplus (molecular assay for detection of Mycobacterium tuberculosis and drug resistance) for rifampicin resistance. We included studies evaluating sputum, gastric aspirate, stool, nasopharyngeal or bronchial lavage specimens (pulmonary tuberculosis), cerebrospinal fluid (tuberculous meningitis), fine needle aspirates, or surgical biopsy tissue (lymph node tuberculosis). Two review authors independently extracted data and assessed study quality using the Quality Assessment of Studies of Diagnostic Accuracy - Revised (QUADAS-2). For each target condition, we used the bivariate model to estimate pooled sensitivity and specificity with 95% confidence intervals (CIs). We stratified all analyses by type of reference standard. We assessed certainty of evidence using the GRADE approach. For pulmonary tuberculosis, 299 data sets (68,544 participants) were available for analysis; for tuberculous meningitis, 10 data sets (423 participants) were available; for lymph node tuberculosis, 10 data sets (318 participants) were available; and for rifampicin resistance, 14 data sets (326 participants) were available. Thirty-nine studies (80%) took place in countries with high tuberculosis burden. Risk of bias was low except for the reference standard domain, for which risk of bias was unclear because many studies collected only one specimen for culture. Detection of pulmonary tuberculosis For sputum specimens, Xpert MTB/RIF pooled sensitivity (95% CI) and specificity (95% CI) verified by culture were 64.6% (55.3% to 72.9%) (23 studies, 493 participants; moderate-certainty evidence) and 99.0% (98.1% to 99.5%) (23 studies, 6119 participants; moderate-certainty evidence). For other specimen types (nasopharyngeal aspirate, 4 studies; gastric aspirate, 14 studies; stool, 11 studies), Xpert MTB/RIF pooled sensitivity ranged between 45.7% and 73.0%, and pooled specificity ranged between 98.1% and 99.6%. For sputum specimens, Xpert Ultra pooled sensitivity (95% CI) and specificity (95% CI) verified by culture were 72.8% (64.7% to 79.6%) (3 studies, 136 participants; low-certainty evidence) and 97.5% (95.8% to 98.5%) (3 studies, 551 participants; high-certainty evidence). For nasopharyngeal specimens, Xpert Ultra sensitivity (95% CI) and specificity (95% CI) were 45.7% (28.9% to 63.3%) and 97.5% (93.7% to 99.3%) (1 study, 195 participants). For all specimen types, Xpert MTB/RIF and Xpert Ultra sensitivity were lower against a composite reference standard than against culture. Detection of tuberculous meningitis For cerebrospinal fluid, Xpert MTB/RIF pooled sensitivity and specificity, verified by culture, were 54.0% (95% CI 27.8% to 78.2%) (6 studies, 28 participants; very low-certainty evidence) and 93.8% (95% CI 84.5% to 97.6%) (6 studies, 213 participants; low-certainty evidence). Detection of lymph node tuberculosis For lymph node aspirates or biopsies, Xpert MTB/RIF pooled sensitivity and specificity, verified by culture, were 90.4% (95% CI 55.7% to 98.6%) (6 studies, 68 participants; very low-certainty evidence) and 89.8% (95% CI 71.5% to 96.8%) (6 studies, 142 participants; low-certainty evidence). Detection of rifampicin resistance Xpert MTB/RIF pooled sensitivity and specificity were 90.0% (67.6% to 97.5%) (6 studies, 20 participants; low-certainty evidence) and 98.3% (87.7% to 99.8%) (6 studies, 203 participants; moderate-certainty evidence). We found Xpert MTB/RIF sensitivity to vary by specimen type, with gastric aspirate specimens having the highest sensitivity followed by sputum and stool, and nasopharyngeal specimens the lowest; specificity in all specimens was > 98%. Compared with Xpert MTB/RIF, Xpert Ultra sensitivity in sputum was higher and specificity slightly lower. Xpert MTB/RIF was accurate for detection of rifampicin resistance. Xpert MTB/RIF was sensitive for diagnosing lymph node tuberculosis. For children with presumed tuberculous meningitis, treatment decisions should be based on the entirety of clinical information and treatment should not be withheld based solely on an Xpert MTB/RIF result. The small numbers of studies and participants, particularly for Xpert Ultra, limits our confidence in the precision of these estimates.
Kay AW ,González Fernández L ,Takwoingi Y ,Eisenhut M ,Detjen AK ,Steingart KR ,Mandalakas AM ... - 《Cochrane Database of Systematic Reviews》
被引量: 57 发表:1970年 -
Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults.
Steingart KR ,Schiller I ,Horne DJ ,Pai M ,Boehme CC ,Dendukuri N ... - 《Cochrane Database of Systematic Reviews》
被引量: 414 发表:1970年 -
Xpert MTB/RIF Ultra assay for tuberculosis disease and rifampicin resistance in children.
Every year, an estimated one million children and young adolescents become ill with tuberculosis, and around 226,000 of those children die. Xpert MTB/RIF Ultra (Xpert Ultra) is a molecular World Health Organization (WHO)-recommended rapid diagnostic test that simultaneously detects Mycobacterium tuberculosis complex and rifampicin resistance. We previously published a Cochrane Review 'Xpert MTB/RIF and Xpert MTB/RIF Ultra assays for tuberculosis disease and rifampicin resistance in children'. The current review updates evidence on the diagnostic accuracy of Xpert Ultra in children presumed to have tuberculosis disease. Parts of this review update informed the 2022 WHO updated guidance on management of tuberculosis in children and adolescents. To assess the diagnostic accuracy of Xpert Ultra for detecting: pulmonary tuberculosis, tuberculous meningitis, lymph node tuberculosis, and rifampicin resistance, in children with presumed tuberculosis. Secondary objectives To investigate potential sources of heterogeneity in accuracy estimates. For detection of tuberculosis, we considered age, comorbidity (HIV, severe pneumonia, and severe malnutrition), and specimen type as potential sources. To summarize the frequency of Xpert Ultra trace results. We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, three other databases, and three trial registers without language restrictions to 9 March 2021. Cross-sectional and cohort studies and randomized trials that evaluated Xpert Ultra in HIV-positive and HIV-negative children under 15 years of age. We included ongoing studies that helped us address the review objectives. We included studies evaluating sputum, gastric, stool, or nasopharyngeal specimens (pulmonary tuberculosis), cerebrospinal fluid (tuberculous meningitis), and fine needle aspirate or surgical biopsy tissue (lymph node tuberculosis). For detecting tuberculosis, reference standards were microbiological (culture) or composite reference standard; for stool, we also included Xpert Ultra performed on a routine respiratory specimen. For detecting rifampicin resistance, reference standards were drug susceptibility testing or MTBDRplus. Two review authors independently extracted data and, using QUADAS-2, assessed methodological quality judging risk of bias separately for each target condition and reference standard. For each target condition, we used the bivariate model to estimate summary sensitivity and specificity with 95% confidence intervals (CIs). We stratified all analyses by type of reference standard. We summarized the frequency of Xpert Ultra trace results; trace represents detection of a very low quantity of Mycobacterium tuberculosis DNA. We assessed certainty of evidence using GRADE. We identified 14 studies (11 new studies since the previous review). For detection of pulmonary tuberculosis, 335 data sets (25,937 participants) were available for analysis. We did not identify any studies that evaluated Xpert Ultra accuracy for tuberculous meningitis or lymph node tuberculosis. Three studies evaluated Xpert Ultra for detection of rifampicin resistance. Ten studies (71%) took place in countries with a high tuberculosis burden based on WHO classification. Overall, risk of bias was low. Detection of pulmonary tuberculosis Sputum, 5 studies Xpert Ultra summary sensitivity verified by culture was 75.3% (95% CI 64.3 to 83.8; 127 participants; high-certainty evidence), and specificity was 97.1% (95% CI 94.7 to 98.5; 1054 participants; high-certainty evidence). Gastric aspirate, 7 studies Xpert Ultra summary sensitivity verified by culture was 70.4% (95% CI 53.9 to 82.9; 120 participants; moderate-certainty evidence), and specificity was 94.1% (95% CI 84.8 to 97.8; 870 participants; moderate-certainty evidence). Stool, 6 studies Xpert Ultra summary sensitivity verified by culture was 56.1% (95% CI 39.1 to 71.7; 200 participants; moderate-certainty evidence), and specificity was 98.0% (95% CI 93.3 to 99.4; 1232 participants; high certainty-evidence). Nasopharyngeal aspirate, 4 studies Xpert Ultra summary sensitivity verified by culture was 43.7% (95% CI 26.7 to 62.2; 46 participants; very low-certainty evidence), and specificity was 97.5% (95% CI 93.6 to 99.0; 489 participants; high-certainty evidence). Xpert Ultra sensitivity was lower against a composite than a culture reference standard for all specimen types other than nasopharyngeal aspirate, while specificity was similar against both reference standards. Interpretation of results In theory, for a population of 1000 children: • where 100 have pulmonary tuberculosis in sputum (by culture): - 101 would be Xpert Ultra-positive, and of these, 26 (26%) would not have pulmonary tuberculosis (false positive); and - 899 would be Xpert Ultra-negative, and of these, 25 (3%) would have tuberculosis (false negative). • where 100 have pulmonary tuberculosis in gastric aspirate (by culture): - 123 would be Xpert Ultra-positive, and of these, 53 (43%) would not have pulmonary tuberculosis (false positive); and - 877 would be Xpert Ultra-negative, and of these, 30 (3%) would have tuberculosis (false negative). • where 100 have pulmonary tuberculosis in stool (by culture): - 74 would be Xpert Ultra-positive, and of these, 18 (24%) would not have pulmonary tuberculosis (false positive); and - 926 would be Xpert Ultra-negative, and of these, 44 (5%) would have tuberculosis (false negative). • where 100 have pulmonary tuberculosis in nasopharyngeal aspirate (by culture): - 66 would be Xpert Ultra-positive, and of these, 22 (33%) would not have pulmonary tuberculosis (false positive); and - 934 would be Xpert Ultra-negative, and of these, 56 (6%) would have tuberculosis (false negative). Detection of rifampicin resistance Xpert Ultra sensitivity was 100% (3 studies, 3 participants; very low-certainty evidence), and specificity range was 97% to 100% (3 studies, 128 participants; low-certainty evidence). Trace results Xpert Ultra trace results, regarded as positive in children by WHO standards, were common. Xpert Ultra specificity remained high in children, despite the frequency of trace results. We found Xpert Ultra sensitivity to vary by specimen type, with sputum having the highest sensitivity, followed by gastric aspirate and stool. Nasopharyngeal aspirate had the lowest sensitivity. Xpert Ultra specificity was high against both microbiological and composite reference standards. However, the evidence base is still limited, and findings may be imprecise and vary by study setting. Although we found Xpert Ultra accurate for detection of rifampicin resistance, results were based on a very small number of studies that included only three children with rifampicin resistance. Therefore, findings should be interpreted with caution. Our findings provide support for the use of Xpert Ultra as an initial rapid molecular diagnostic in children being evaluated for tuberculosis.
Kay AW ,Ness T ,Verkuijl SE ,Viney K ,Brands A ,Masini T ,González Fernández L ,Eisenhut M ,Detjen AK ,Mandalakas AM ,Steingart KR ,Takwoingi Y ... - 《Cochrane Database of Systematic Reviews》
被引量: 23 发表:1970年
加载更多
加载更多
加载更多