Direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer treatment: Choosing the optimal shielding material.

来自 PUBMED

作者:

Safigholi HHan DYSoliman ASong WY

展开

摘要:

To investigate the dose modulation capability of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator design with various high-density shielding materials for brachytherapy treatment of cervical cancer. The shield materials that have been evaluated are tantalum (Ta), pure tungsten (W), gold (Au), rhenium (Re), osmium (Os), platinum (Pt), iridium (Ir), and W' tungsten alloy (95%W, 3.5%Ni, 1.5%Cu). The recently proposed six-channel DMBT tandem is composed of nonmagnetic tungsten alloy (W') rod with diameter of 5.4 mm and coated with 0.3-mm thick bio-safe plastic sheath. The tandem shielding material can, however, be individually replaced with various other shields to create directional radiation. Monte Carlo N-Particle (MCNP) code was used to calculate the three-dimensional (3D) dose distributions in a water phantom for an HDR 192 Ir (mHDR-v2) source inside each DMBT tandem with various shields and a plastic conventional tandem (Con.T). Then, the 3D dose distributions were imported into an in-house-coded inverse planning optimization algorithm to obtain optimal plans for 12 clinical cases chosen at random from the international RetroEMBRACE dataset involving conventional tandem and ring (Con.T&R) applicators. All plans generated by the DMBT tandem and ring (DMBT&R) with the tungsten alloy [DMBT(W')&R] were compared with the corresponding Con.T&R plans, to generate benchmark results. These benchmark results were then considered as reference plans for other shields performances. Plans were normalized to receive the same high-risk clinical target volume (CTVHR ) D90 . The D100 , D10 , and V100 for CTVHR , and D2cm3 for organs at risk (OARs) of bladder, sigmoid, and rectum were calculated and compared. Transmission factor (TF), that is, the dose in the backside of the DMBT shield over that in the front opening, at a 5 cm distance, were 36.6%, 34.8%, 31.9%, 28.9%, 27.9%, 26.2%, 26.2%, and 25.5%, for Ta, W', W, Re, Au, Os, Pt, and Ir shields, respectively. On average, the CTVHR values for D100 , V100 , D10 were not significantly different across all DMBT&R shields and the Con.T&R plans (P > 0.219). For the D2cm3 , the benchmark results showed significant reductions (P < 0.03), that is, on average, -8.3% for bladder, -10.7% for rectum, and -10.1% for sigmoid, compared to the Con.T&R plans. However, the various shields showed little improvement from the tungsten alloy (W'), where on average, rectum (bladder) [sigmoid] D2cm3 were reduced by -1.32% (-0.85%) [-1.01%], -1.25% (-0.78%) [-0.91%], -1.22% (-0.75%) [-0.86%], -0.94% (-0.60%) [-0.70%], -0.84% (-0.51%) [-0.59%], and -0.38% (-0.24%) [-0.23%] for Ir, Pt, Os, Au, Re, and W shields, relative to the benchmark W' DMBT plans, respectively. These corresponding values for Ta increased by +0.28% (+0.08%) [+0.25%], respectively. The Ir, Pt, Os, Au, Re, and W shielding materials, respectively, in descending order, lead to better OAR sparing than the DMBT(W')&R plans. However, the amount of improvement is limited and clinically insignificant. This finding suggests that the initial W' shield remains a suitable choice given the proven MR compatibility, for use in MR-guided adaptive brachytherapy of cervical cancer.

收起

展开

DOI:

10.1002/mp.13030

被引量:

6

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(122)

参考文献(0)

引证文献(6)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读