Development of a novel methodology for QA of respiratory-gated and VMAT beam delivery using Octavius 4D phantom.

来自 PUBMED

作者:

Yang BGeng HDing YKong CWCheung CWChiu TLLam WWCheung KYYu SK

展开

摘要:

The objective of this study was to develop and evaluate a series of quality assurance (QA) techniques based on Octavius 4D phantom for testing of respiratory-gated treatment delivery, integrity of dose rate vs gantry speed in volumetric-modulated arc therapy (VMAT) commissioning, and multileaf collimator (MLC) positioning accuracy of a linear accelerator. An Octavius 4D phantom capable of rotating with the gantry and recording the detector signal with a sampling rate of 10 Hz was isocentrally set up and an inclinometer was also installed to measure the gantry angle simultaneously. A simple arc test was created and delivered with gating function activated to measure the timing accuracy of the gating window. A tailor-made dose rate vs gantry speed plan was also designed to test the accuracy of measured dose rate, gantry speed, and actual control points. All experiments were conducted while machine log files were collected for comparison. The variations of beam flatness, symmetry, and field size were analyzed as a function of gantry angle to evaluate the influence from the modulation of dose rate and gantry speed. MLC position accuracy was evaluated based on specific garden fence plans. The time of gating window was measured to be less than 10-millisecond deviation from the log data. Gantry backlash was observed and quantified to be 1.72° with an extra stabilization time of 1.16 seconds for a gating arc with gantry speed of 6°/s. In the dose rate vs gantry speed test, the mean deviation between measured gantry angle and log data was less than 0.2° after a time delay of 0.25 second was corrected. The measured dose rate agreed with the log data very well with a mean deviation of 0.05%, and even the transit of modulation was tracked successfully. There was a statistically significant difference on the variation of beam parameters between a VMAT plan and a simple arc plan. The induced MLC position errors were detected with an accuracy of 0.05 mm. The leaf position reproducibility was found to be better than 0.02 mm, whereas the routine MLC position accuracy was better than 0.1 mm. A time-resolved method using Octavius 4D phantom has been developed and proven to be convenient for respiratory gating QA, dose rate vs gantry speed test, and MLC QA. Gating time, dose rate, and gantry speed-induced leave position error could be directly measured with high accuracy after comparison with the machine log data. This study also highlights the capability of the phantom in quantifying the variation of flatness, symmetry, and field size during gantry rotation.

收起

展开

DOI:

10.1016/j.meddos.2018.02.008

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(272)

参考文献(0)

引证文献(4)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读