Determination of kQmsr,Q0fmsr,fref factors for ion chambers used in the calibration of Leksell Gamma Knife Perfexion model using EGSnrc and PENELOPE Monte Carlo codes.

来自 PUBMED

作者:

Mirzakhanian LBenmakhlouf HTessier FSeuntjens J

展开

摘要:

To calculate the kQmsr,Q0fmsr,fref factors for nine common ionization chamber types following the small fields dosimetry formalism for the calibration of the Leksell Gamma Knife® (LGK) PerfexionTM using Monte Carlo simulation. This study also provides the first independent comparison of EGSnrc and PENELOPE for the calculation of kQmsr,Q0fmsr,fref correction factors and proposes a practical method to predict these factors based on chamber type, chamber orientation and phantom electron density. The ionization chambers are modeled using the EGSnrc and PENELOPE Monte Carlo codes based on the blueprints provided by the manufacturers. The chambers are placed in a half-sphere water phantom and five spherical phantoms made of liquid water, solid water, ABS, polystyrene, and PMMA, respectively. Dose averaged over the air cavity of the chambers and a small water volume are calculated using EGSnrc and PENELOPE Monte Carlo codes for both conventional and machine specific reference (msr) setups. Using the calculated dose ratio, the kQmsr,Q0fmsr,fref factor is determined for all phantom materials and two possible orientations of chamber. The calculated kQmsr,Q0fmsr,fref factors are compared to a previous Monte Carlo study. A relationship between the kQmsr,Q0fmsr,fref factor and the electron density of the phantom material is derived to predict the kQmsr,Q0fmsr,fref factor for any phantom material type. Applying the calculated kQmsr,Q0fmsr,fref factors to the measured dose rate of a recent round robin study improves consistency of reference dosimetry of the Leksell Gamma Knife® (LGK) PerfexionTM . Agreement within uncertainty is observed between kQmsr,Q0fmsr,fref values determined in this study and the previous PEGASOS/PENELOPE study in a liquid water phantom. The difference between kQmsr,Q0fmsr,fref values in parallel and perpendicular detector orientations is most significant for the PTW 31010 (1.8%) chamber. The percentage root-mean-square (%RMS) deviation between EGSnrc and PENELOPE calculated kQmsr,Q0fmsr,fref values for Exradin-A1SL, A14 and A14SL chambers studies in this work was found to be 0.4%. The kQmsr,Q0fmsr,fref values increase linearly with electron density of the phantom material for all chamber types mainly due to the linear dependency of photon energy fluence ratios on electron density. The average percentage difference between the calculated and predicted kQmsr,Q0fmsr,fref values using two methods is found to be 0.15% and 0.16%. Previously measured dose rates corrected with the kQmsr,Q0fmsr,fref values determined in this work leads to absorbed dose values consistent to within 0.8%. The calculated kQmsr,Q0fmsr,fref values in this work will enable users to apply the appropriate correction for their own specific phantom material only knowing the electron density of the phantom material.

收起

展开

DOI:

10.1002/mp.12821

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(777)

参考文献(0)

引证文献(4)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读