A real-time method to simultaneously measure linear energy transfer and dose for proton therapy using organic scintillators.

来自 PUBMED

作者:

Alsanea FTherriault-Proulx FSawakuchi GBeddar S

展开

摘要:

Currently, no detectors are capable of simultaneously measuring dose and linear energy transfer (LET) in real time. In this study, we evaluated the feasibility of exploiting the difference in the response of various organic plastic scintillation detectors to measure LET and dose in therapeutic proton beams. The hypothesis behind this work was that the ratio of the responses of different scintillators exposed to the same proton beam can be used to obtain a LET vs ratio calibration curve that can then be used to infer LET under any other measurement conditions. We first used similar scintillators with different ionization quenching factors. LET values for different irradiation conditions were calculated using a validated Monte Carlo model of the proton beam line. The quenching factors in the Birks equation for different scintillators as a function of LET were obtained from measurements in a 100-MeV pristine proton beam. We then used four different organic scintillation materials - polystyrene (BCF-12), poly (methyl methacrylate), polyvinyltoluene, and a liquid scintillator - for which the LET response varied with regard to not only quenching but also differences in material density and relative stopping power. We simultaneously exposed the four different organic scintillators and a plane-parallel ion chamber to passively scattered proton beams at fluence-averaged LET. Comparisons to the expected values obtained from the Monte Carlo simulations were made on the basis of both dose and LET. The maximum difference in the quenching factor was 20%, resulting in a 5% change in LET with a response ratio over a range of 5 keV/μm. Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation with LET values and was therefore used to construct the LET calibration curve. The expected LET values in the validation set were within 2% ± 6%, which resulted in dose accuracy of 1.5% ± 5.8% for the range of LET values investigated in this work. We demonstrated the feasibility of using the ratio of the light outputs of two organic scintillators to simultaneously measure LET and dose in therapeutic proton beams for fluence-averaged LET values from 0.47 to 1.26 keV/μm. Further studies are needed to verify the response for higher LET values and the reproducibility of this method.

收起

展开

DOI:

10.1002/mp.12815

被引量:

5

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(165)

参考文献(24)

引证文献(5)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读